Comparison of 9 intraocular lens power calculation formulas

被引:199
|
作者
Cooke, David L. [1 ,2 ]
Cooke, Timothy L. [1 ]
机构
[1] Great Lakes Eye Care, 2848 Niles Rd, St Joseph, MI 49085 USA
[2] Michigan State Univ, Coll Osteopath Med, Dept Neurol & Ophthalmol, E Lansing, MI 48824 USA
来源
关键词
HOFFER-Q FORMULA; PREDICTION ACCURACY; AXIAL LENGTHS;
D O I
10.1016/j.jcrs.2016.06.029
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the accuracy of 9 intraocular lens (IOL) calculation formulas using 2 optical biometers. SETTING: Private practice, Saint Joseph, Michigan, USA. DESIGN: Retrospective consecutive case series. METHODS: Nine IOL power formula predictions with observed refractions after cataract surgery were compared using 1 IOL platform. The performance of each formula was ranked for accuracy by machine and by axial length (AL). The Olsen was further divided by a preinstalled version (Olsen(OLCR)) and a purchased version (Olsen(Standalone)). The Holladay 2 was divided by whether a refraction was entered (Holladay 2(PreSurgRef)) or not (Holladay 2(NoRef)). The OLCR device used in the study was the Lenstar L5 900 and the PCI device, the IOLMaster. RESULTS: The formulas were ranked by the standard deviation of the prediction error (optical low coherence reflectometry [OLCR], partial coherence interferometry [PCI]) as follows: Olsen(Standalone) (0.361, 0.446), Barrett Universal II (0.365, 0.387), Olsen(OLCR) (0.378, not applicable), Haigis (0.393, 0.401), T2 (0.397, 0.404), Super Formula (0.403, 0.410), Holladay 2(NoRef) (0.404, 0.417), Holladay 1 (0.408, 0.414), Holladay 2(PreSurgRef) (0.423, 0.432), Hoffer Q (0.428, 0.432), and SRK/T (0.433, 0.44). CONCLUSIONS: The formulas gave different results depending on which machine measurements were used. The Olsen formula was the most accurate with OLCR measurements, significantly better than the best formula with PCI measurements. The Olsen was better, regardless of AL. If only PCI measurements (without lens thickness) were available, the Barrett Universal II performed the best and the Olsen formula performed the worst. The preinstalled version of Olsen was not as good as the standalone version. The Holladay 2 formula performed better when the preoperative refraction was excluded.
引用
收藏
页码:1157 / 1164
页数:8
相关论文
共 50 条
  • [21] Comparative Evaluation of Intraocular Lens Power Calculation Formulas in Children
    Rastogi, Anju
    Jaisingh, Kirti
    Suresh, Priyadarshini
    Anand, Kamlesh
    Baindur, Siddharth
    Gaonker, Tanvi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (05)
  • [22] Evaluation of the Accuracy of Intraocular Lens Power Calculation Formulas in Phacovitrectomy
    Tanaka, Yuichiro
    Kamiya, Kazutaka
    Igarahi, Akihito
    Shoji, Nobuyuki
    Tsuchiya, Hiroshi
    Takahashi, Shinya
    Ishikawa, Eri
    Kozawa, Tadahiko
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (08) : 2197 - 2208
  • [23] Intraocular Lens Power Calculation Formulas-A Systematic Review
    Stopyra, Wiktor
    Langenbucher, Achim
    Grzybowski, Andrzej
    OPHTHALMOLOGY AND THERAPY, 2023, 12 (06) : 2881 - 2902
  • [24] Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation
    Shi, Jingyi
    Zhu, Zehui
    Hu, Bin
    Qian, Shuyi
    Wang, Yalan
    Chang, Pingjun
    Zhao, Yun-e
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (05) : 1321 - 1342
  • [25] Accuracy of New Intraocular Lens Power Calculation Formulas: A Lens Thickness Study
    Taroni, Leonardo
    Hoffer, Kenneth J.
    Lupardi, Enrico
    Barboni, Piero
    Savini, Giacomo
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (03) : 202 - 206
  • [26] Update on Intraocular Lens Calculation Formulas
    Melles, Ronald B.
    Kane, Jack X.
    Olsen, Thomas
    Chang, William J.
    OPHTHALMOLOGY, 2019, 126 (09) : 1334 - 1335
  • [27] Accuracy of Intraocular Lens Calculation Formulas
    Melles, Ronald B.
    Holladay, Jack T.
    Chang, William J.
    OPHTHALMOLOGY, 2018, 125 (02) : 169 - 178
  • [28] Accuracy of the Kane Formula for Intraocular Lens Power Calculation in Comparison with Existing Formulas: A Retrospective Review
    Ryu, Soyoung
    Jun, Ikhyun
    Kim, Tae-im
    Kim, Eung Kweon
    Seo, Kyoung Yul
    YONSEI MEDICAL JOURNAL, 2021, 62 (12) : 1117 - 1124
  • [29] Comparison of the accuracy of intraocular lens power calculation formulas for eyes after corneal refractive surgery
    Wang, Xiao-Zhen
    Cui, Rui
    Song, Xu-Dong
    Yun, Bo
    Qian, Jin
    Ding, Ning
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (14)
  • [30] Comparison of the accuracy of nine intraocular lens power calculation formulas using partial coherence interferometry
    Maroun, A.
    El Shami, M.
    Hoyek, S.
    Antoun, J.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2023, 46 (04): : 341 - 347