共 47 条
Backside interferometric methods for localization of ESD-induced leakage current and metal shorts
被引:3
|作者:
Dubec, V.
Bychikhin, S.
Pogany, D.
Gornik, E.
Brodbeck, T.
Stadler, W.
机构:
[1] Vienna Univ Technol, Inst Solid State Elect, A-1040 Vienna, Austria
[2] Infineon Technol, COM BTS LIB IO, D-81726 Munich, Germany
关键词:
D O I:
10.1016/j.microrel.2007.07.029
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
Transient interferometric mapping (TIM) setup for ns-time ESD testing is adapted for post-stress failure analysis. Probing from the chip backside using the thermo-optical effect is used for localization of heating place related to failure. Two variants of 2D holographic interferometers, a Michelson and a "Wollaston" one, are used for a rough identification of a failure site. An adapted scanning heterodyne interferometer is used for accurate position determination with a 2 mu m space resolution. The methods are applied to identify ESD damage and metal shorts. Sensitivity and space resolution are analyzed, supported by a 3D-thermal simulation of repetitive heating signal. A power sensitivity of 50 mu W for a single point heat source is demonstrated. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1539 / 1544
页数:6
相关论文