Detection and classification of gaseous microemboli during Pulsatile and nonpulsatile perfusion in a simulated neonatal CPB model

被引:29
|
作者
Uendar, Akif
Ji, Bingyang
Kunselman, Allen R.
Myers, John L.
机构
[1] Penn State Childrens Hosp, Penn State Milton S Hershey Med Ctr, Penn State Coll Med, Dept Pediat, Hershey, PA USA
[2] Penn State Childrens Hosp, Penn State Milton S Hershey Med Ctr, Penn State Coll Med, Dept Surg, Hershey, PA USA
[3] Penn State Childrens Hosp, Penn State Milton S Hershey Med Ctr, Penn State Coll Med, Dept Bioengn, Hershey, PA USA
[4] Penn State Childrens Hosp, Penn State Milton S Hershey Med Ctr, Penn State Coll Med, Dept Hlth Evaluat Sci, Hershey, PA USA
关键词
D O I
10.1097/MAT.0b013e3181588dc3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We compared the effects of perfusion modes (pulsatile vs. nonpulsatile) on gaseous microemboli delivery using the Emboli Detection and Classification (EDACTM) Quantifier at postpump, postoxygenator, and postarterial filter sites in a simulated pediatric cardiopulmonary bypass (CPB) model. The mock loop was subjected to five different pump flow rates of equal 100 ml/min intervals, ranging from 400 to 800 ml/min. When the target pump flow rate was achieved, 5 cc air was introduced into the venous line. The EDACTM system recorded gaseous microemboli counts simultaneously at three locations in 5-minute intervals. Regardless of the type of perfusion mode, when the pump flow rate was increased, more gaseous microemboli were generated at postpump site. Compared with nonpulsatile flow, pulsatile flow did deliver significantly more gaseous microemboli at postpump site, but there was no difference between two groups at postoxygenator and postarterial filter sites. Capiox Baby-RX hollow-fiber membrane oxygenator significantly reduced the gaseous microemboli counts in both groups at all five pump flow rates with either pulsatile flow or nonpulsatile flow in this model. Our results suggest that using this novel EDAC (TM) system, we could detect the size of gaseous microemboli, as small as 10 mu m, and the percentage of detected gaseous microemboli, <40 mu m, was about 90% in total gaseous microemboli counts at any flow rate with pulsatile or nonpulsatile flow.
引用
收藏
页码:725 / 729
页数:5
相关论文
共 50 条
  • [21] Precise quantification of pressure-flow waveforms during pulsatile and nonpulsatile perfusion - Reply
    Desai, Nimesh
    Fremes, Stephen E.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 133 (05): : 1396 - 1397
  • [22] The effects of pulsatile versus nonpulsatile perfusion on blood viscoelasticity before and after deep hypothermic circulatory arrest in a neonatal piglet model
    Ündar, A
    Henderson, N
    Thurston, GB
    Masai, T
    Beyer, EA
    Frazier, OH
    Fraser, CD
    ARTIFICIAL ORGANS, 1999, 23 (08) : 717 - 721
  • [23] The alphabet of research on pulsatile and nonpulsatile (continuous flow) perfusion during chronic support - Reply
    Nishinaka, T
    Tatsumi, E
    Taenaka, Y
    Takano, H
    ARTIFICIAL ORGANS, 2002, 26 (09) : 813 - 815
  • [24] HEMODYNAMIC ANALYSIS OF EFFICACY OF PULSATILE PERFUSION DURING CPB WITH A NEW CENTRIFUGAL PUMP
    Dodonov, M.
    Milano, A.
    Faggian, G.
    Gu, J.
    Tessari, M.
    Menon, T.
    De Jong, E.
    Mazzucco, A.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (08): : 638 - 638
  • [25] GASEOUS MICROEMBOLI DURING CANINE HYPOTHERMIC BYPASS DO NOT ALTER CEREBRAL PERFUSION
    JOHNSTON, WE
    STUMP, DA
    DEWITT, DS
    VINTENJOHANSEN, J
    PROUGH, DS
    CIRCULATION, 1992, 86 (04) : 567 - 567
  • [26] The effects of pulsatile flow upon renal tissue perfusion during cardiopulmonary bypass: A comparative study of pulsatile and nonpulsatile flow
    Kim, HK
    Son, HS
    Fang, YH
    Park, SY
    Hwang, CM
    Sun, K
    ASAIO JOURNAL, 2005, 51 (01) : 30 - 36
  • [27] Cardiac surgery during pregnancy: Pulsatile or nonpulsatile perfusion? (vol 126, pg 894, 2003)
    Prefumo, F
    Clarke, J
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (05): : 1680 - 1680
  • [28] Microemboli generation, detection and characterization during CPB procedures in neonates, infants, and small children
    Win, Khin N.
    Wang, Shigang
    Undar, Akif
    ASAIO JOURNAL, 2008, 54 (05) : 486 - 490
  • [29] EFFECTS OF PULSATILE ASSISTANCE AND NONPULSATILE FLOW ON SUB-ENDOCARDIAL PERFUSION DURING CARDIOPULMONARY BYPASS
    STEED, DL
    FOLLETTE, DM
    FOGLIA, R
    MALONEY, JV
    BUCKBERG, GD
    ANNALS OF THORACIC SURGERY, 1978, 26 (02): : 133 - 141
  • [30] Microemboli Detection and Classification During Pediatric Cardiopulmonary Bypass
    Clark, Joseph B.
    Qiu, Feng
    Guan, Yulong
    Woitas, Karl R.
    Myers, John L.
    Undar, Akif
    WORLD JOURNAL FOR PEDIATRIC AND CONGENITAL HEART SURGERY, 2011, 2 (01) : 111 - 114