Radiation skyshine from a 6 MeV medical accelerator

被引:7
|
作者
Gossman, Michael S. [1 ]
McGinley, Patton H.
Rising, Mary B. [2 ]
Pahikkala, A. Jussi
机构
[1] Tri State Reg Canc Ctr, Med Phys Sect, Ashland, KY 41101 USA
[2] Univ Louisville, Dept Math, Louisville, KY 42092 USA
来源
关键词
scattering; shielding; skyshine; solid angle; FACILITY; ROOF;
D O I
10.1120/jacmp.v11i3.3032
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study assesses the dose level from skyshine produced by a 6 MeV medical accelerator. The analysis of data collected on skyshine yields professional guidance for future investigators as they attempt to quantify and qualify radiation protection concerns in shielding therapy vaults. Survey measurements using various field sizes and at varying distances from a primary barrier have enabled us to identify unique skyshine behavior in comparison to other energies already seen in literature. In order to correctly quantify such measurements outside a shielded barrier, one must take into consideration the fact that a skyshine maximum may not be observed at the same distance for all field sizes. A physical attribute of the skyshine scatter component was shown to increase to a maximum value at 4.6 m from the barrier for the largest field size used. We recommend that the largest field sizes be used in the field for the determination of skyshine effect and that the peak value be further analyzed specifically when considering shielding designs.
引用
收藏
页码:259 / 264
页数:6
相关论文
共 50 条
  • [31] A COMPACT 6 MEV PULSED ELECTRON-ACCELERATOR
    HUTCHEON, RM
    FUNK, LW
    GILLIES, BA
    HODGE, SB
    METIVIER, PJ
    SCHRIBER, SO
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (02) : 1418 - 1420
  • [32] RADIATION CONDITIONS IN A 16-MEV ELECTRON MICROTRON ACCELERATOR
    BELOV, AG
    KOMENDANTOVA, GA
    TETEREV, YG
    CHEREVATENKO, AP
    SOVIET ATOMIC ENERGY, 1983, 54 (01): : 35 - 41
  • [33] Fast neutron leakage in 18 MEV medical electron accelerator
    Paredes, L.
    Genis, R.
    Balcázar, M.
    Tavera, L.
    Camacho, E.
    Radiation Measurements, 1999, 31 (01): : 475 - 478
  • [34] Fast neutron leakage in 18 MeV medical electron accelerator
    Paredes, L
    Genis, R
    Balcázar, M
    Tavera, L
    Camacho, E
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 475 - 478
  • [35] RADIATION PROTECTION PROGRAM FOR A 10-MEV LINEAR ACCELERATOR
    BOZICH, TA
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1965, 26 (03): : 311 - &
  • [36] SKYSHINE RADIATION FROM APRESSURIZED WATER-REACTOR CONTAINMENT DOME
    PENG, WH
    NUCLEAR TECHNOLOGY, 1986, 73 (03) : 286 - 295
  • [37] A review of photon beam skyshine studies from medical megavoltage accelerators
    Molazadeh, Mikaeil
    Ghiasi, Hosein
    APPLIED RADIATION AND ISOTOPES, 2025, 219
  • [38] Leakage neutron radiation in a medical electron accelerator
    Paredes, L
    Balcazar, M
    Genis, R
    Ortiz, R
    MEDICAL PHYSICS, 2001, 593 : 140 - 147
  • [39] ESTIMATION OF NEUTRON SKYSHINE AND SAFETY LEVEL FROM JORDAN VAN DE GRAAFF ACCELERATOR.
    Saleh, N.
    Hallak, A.
    Abujafar, M.
    Applied physics communications, 1986, 6 (2-3): : 165 - 175
  • [40] Measurements of residual radiation spectra from neutron activation in a medical linear accelerator
    Schifter, D.
    Djamil, T.
    Schory, T.
    EJC SUPPLEMENTS, 2007, 5 (04): : 84 - 84