Fast neutron leakage in 18 MeV medical electron accelerator

被引:14
|
作者
Paredes, L
Genis, R
Balcázar, M
Tavera, L
Camacho, E
机构
[1] Inst Nacl Invest Nucl, Mexico City 11801, DF, Mexico
[2] Fdn Clin Med Sur, Mexico City 14050, DF, Mexico
关键词
fast neutron leakage; medical accelerator; CR-39 track dosimeter;
D O I
10.1016/S1350-4487(99)00199-7
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this work the neutron fluence of the Varian Clinac 2100C Medical Accelerator has been evaluated using CR39 track dosimeter. The assessment of fast neutron dose to a patient for typical treatment of 200 cGy with an 18 MV photons beam is performed at surface-source distance of 100 cm with a field size of 20x20 cm(2) Fast neutron leakage around of the accelerator head is evaluated.
引用
收藏
页码:475 / 478
页数:4
相关论文
共 50 条
  • [1] Fast neutron leakage in 18 MEV medical electron accelerator
    Paredes, L.
    Genis, R.
    Balcázar, M.
    Tavera, L.
    Camacho, E.
    Radiation Measurements, 1999, 31 (01): : 475 - 478
  • [2] Leakage neutron radiation in a medical electron accelerator
    Paredes, L
    Balcazar, M
    Genis, R
    Ortiz, R
    MEDICAL PHYSICS, 2001, 593 : 140 - 147
  • [3] A detailed study on the neutron contamination for a 10 MeV medical electron accelerator
    Chen, C. C.
    Sheu, R. J.
    Yeh, C. Y.
    Lin, U. T.
    Jiang, S. H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 562 (02): : 1033 - 1037
  • [4] MEASUREMENT AND CALCULATION OF NEUTRON LEAKAGE FROM A MEDICAL ELECTRON-ACCELERATOR
    UWAMINO, Y
    NAKAMURA, T
    OHKUBO, T
    HARA, A
    MEDICAL PHYSICS, 1986, 13 (03) : 374 - 384
  • [5] HOW TO MEASURE NEUTRON HEAD LEAKAGE FROM A MEDICAL ELECTRON-ACCELERATOR
    MCCALL, RC
    JENKINS, TM
    MEDICAL PHYSICS, 1981, 8 (04) : 574 - 574
  • [6] Measurement of the neutron leakage from a dedicated intraoperative radiation therapy electron linear accelerator and a conventional linear accelerator for 9, 12, 15(16), and 18(20) MeV electron energies
    Jaradat, Adnan K.
    Biggs, Peter J.
    MEDICAL PHYSICS, 2008, 35 (05) : 1711 - 1717
  • [7] Monte Carlo Calculations of Skyshine Neutron Doses from an 18 MeV Medical Linear Accelerator
    Nariyama, Nobuteru
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3, 2019, 68 (03): : 529 - 531
  • [8] MEASUREMENT OF NEUTRON LEAKAGE SPECTRA AT A 500-MEV PROTON ACCELERATOR
    MORITZ, LE
    HEALTH PHYSICS, 1989, 56 (03): : 287 - 296
  • [9] NEUTRON LEAKAGE MEASUREMENTS FROM A MEDICAL LINEAR-ACCELERATOR
    PALTA, JR
    HOGSTROM, KR
    TANNANONTA, C
    MEDICAL PHYSICS, 1984, 11 (04) : 498 - 501
  • [10] 5 MEV LINEAR ELECTRON ACCELERATOR FOR MEDICAL PURPOSES
    LEVIN, VM
    RUMYANTS.VV
    SOVIET ATOMIC ENERGY-USSR, 1968, 25 (05): : 1271 - &