Glassy carbon electrode modified with 3D graphene-carbon nanotube network for sensitive electrochemical determination of methotrexate

被引:105
|
作者
Asadian, Elham [1 ]
Shahrokhian, Saeed [1 ,2 ]
Zad, Azam Iraji [1 ,3 ]
Ghorbani-Bidkorbeh, Fatemeh [4 ]
机构
[1] Sharif Univ Technol, Inst Nanosci & Nanotechnol INST, Azadi Ave, Tehran, Iran
[2] Sharif Univ Technol, Dept Chem, Azadi Ave, Tehran 111559516, Iran
[3] Sharif Univ Technol, Dept Phys, Azadi Ave, Tehran 1458889694, Iran
[4] Shahid Beheshti Univ Med Sci, Sch Pharm, Dept Pharmaceut, Tehran, Iran
来源
关键词
3D-Network; Graphene; Carbon nanotube; Electrodeposition; Methotrexate; Voltammetry; OXIDE; HYBRID; SENSOR; ACID;
D O I
10.1016/j.snb.2016.08.064
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present study, a 3D porous graphene-carbon nanotube (G-CNT) network is successfully constructed on the surface of glassy carbon electrode (GCE) by electrochemical co-deposition from a concentrated graphene dispersion. The large accessible surface area provided by the interpenetrated graphene backbone in one hand and the enhanced electrical conductivity of the 3D network by incorporating CNTs on the other hand, dramatically improved the electrochemical performance of GCE in determination of Methotrexate (MTX) as an important electroactive drug compound. Under the optimum conditions, the electrode modification led to a significant increase in the anodic peak current (similar to 25 times) along with a considerable shift in the peak potential (similar to 111 mV). Voltammetric investigations revealed that the proposed method can determine MTX in a wide dynamic linear range with a low detection limit of 70 nM. Moreover, good sensitivity and high accuracy of the prepared modified electrode in voltammetric detections of MTX, which was further confirmed by UV-vis spectroscopy and HPLC methods, make it very suitable for accurate determinations of MTX in pharmaceutical formulations (commercial tablets) and clinical preparations (blood serum) with excellent recoveries. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:617 / 627
页数:11
相关论文
共 50 条
  • [41] HEAT TRANSFER ANALYSES OF A 3D GRAPHENE-CARBON NANOTUBE PILLARED STRUCTURE
    Zhao, Weihuan
    Almahmoud, Khaled
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2018, VOL 8B, 2019,
  • [42] A Corrugated Graphene-Carbon Nanotube Composite as Electrode Material
    Zhang, Meixi
    Alvarez, Noe T.
    Zhao, Daoli
    Zhang, Lu
    Haase, Mark R.
    Malik, Rachit
    Katuscak, Christopher
    Wang, Tingting
    Shanov, Vesselin
    NANO LIFE, 2014, 4 (04)
  • [43] Sensitive Electrochemical Determination of Catechol with a Graphene Modified Carbon Ionic Liquid Electrode
    Ruan, Chengxiang
    Li, Tongtong
    Wang, Xiuzheng
    Qi, Xiaowei
    Lou, Jin
    Gao, Weimin
    Sun, Wei
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2012, 59 (12) : 1584 - 1590
  • [44] Sensitive Electrochemical Detection of Dopamine With a Nitrogen-doped Graphene Modified Glassy Carbon Electrode
    Wang, Wencheng
    Gong, Shixing
    Sun, Wei
    Li, Guangjiu
    Lu, Yaping
    Yu, Jianhua
    Dong, Lifeng
    CROATICA CHEMICA ACTA, 2016, 89 (03) : 323 - 330
  • [45] Determination of Rutin by a Graphene-Modified Glassy Carbon Electrode
    Lei, Yan
    Du, Danxin
    Tang, Lina
    Tan, Chenkun
    Chen, Keli
    Zhang, Guo-Jun
    ANALYTICAL LETTERS, 2015, 48 (06) : 894 - 906
  • [46] VOLTAMMETRIC DETERMINATION OF RUPATADINE AT GRAPHENE MODIFIED GLASSY CARBON ELECTRODE
    Devnani, H.
    Singh, P.
    Saxena, S.
    Satsangee, S. P.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2014, 5 (11):
  • [47] Electrochemical behavior of eriocitrin and highly sensitive determination based on an electrochemically reduced graphene oxide modified glassy carbon electrode
    Yao, Shuyu
    Cai, Wanling
    Liu, Lin
    Liao, Xueqing
    Tao, Kaili
    Feng, Fang
    Yang, Gongjun
    ANALYTICAL METHODS, 2016, 8 (18) : 3722 - 3729
  • [48] Voltammetric Determination of Bergenin with Graphene Modified Glassy Carbon Electrode
    Li, Xiaobao
    Zou, Ruyi
    Niu, Yanyan
    Shao, Taiming
    Chen, Yong
    Sun, Wei
    He, Mengxiong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (02): : 1976 - 1984
  • [49] Electrochemical determination of morphine at ordered mesoporous carbon modified glassy carbon electrode
    Li, Fei
    Song, Jixia
    Shan, Changsheng
    Gao, Dongmei
    Xu, Xiaoyu
    Niu, Li
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (06): : 1408 - 1413
  • [50] Electrochemical behavior of methyl parathion and its sensitive determination at a glassy carbon electrode modified with ordered mesoporous carbon
    Pan, Deng
    Ma, Shumin
    Bo, Xiangjie
    Guo, Liping
    MICROCHIMICA ACTA, 2011, 173 (1-2) : 215 - 221