Dose rate and energy distributions of X rays from a linear accelerator at the maze entrance of a radiotherapy room by measurement and Monte Carlo simulation

被引:7
|
作者
Al-Affan, IAM [1 ]
Smith, CW
Morgan, HM
Lillicrap, SC
机构
[1] Velindre NHS Trust, Cardiff CF4 7XL, S Glam, Wales
[2] Royal United Hosp, Wessex Reg Med Phys Serv, Bath BA1 3NG, Avon, England
关键词
D O I
10.1093/oxfordjournals.rpd.a032360
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The dose rates in a radiotherapy room and maze were measured and computed, using the Monte Carlo code for neutron and photon transport, MCNP, for 6 MV X rays at different field sizes and gantry angles. The contribution from leakage was also measured and computed. When a phantom (patient) was positioned at the isocentre the measured and computed doses at the maze entrance were increased by a factor of 2-3 times over that without a phantom present. The size of the phantom on which the primary beam was incident was not a sensitive factor in increasing the dose rate at the maze entrance. There was good agreement between the measurements and MCNP computations. The energy spectra of the photons (both the scattered and leakage components) near the maze entrance were measured and computed for a primary beam with a field size 20 mm x 20 mm for scatter and leakage.
引用
收藏
页码:273 / 277
页数:5
相关论文
共 50 条
  • [21] Evaluation of the contribution of capture gamma rays, x-ray leakage, and scatter to the photon dose at the maze door for a high energy medical electron accelerator using a Monte Carlo particle transport code
    McGinley, PH
    Dhaba'an, AH
    Reft, CS
    MEDICAL PHYSICS, 2000, 27 (01) : 225 - 230
  • [22] Monte Carlo Simulation of a Modified Elekta Precise Linear Accelerator Used for Flash Radiotherapy Using TOPAS (TOol for PArticle Simulation)
    Rimchi, Fatima Zahra
    Moussa, Abdelilah
    El Hamil, Abdelkader
    Tayalati, Yahya
    ADVANCES IN SMART MEDICAL, IOT & ARTIFICIAL INTELLIGENCE, VOL 1, ICSMAI 2024, 2024, 11 : 215 - 223
  • [23] Influence of initial electron beam characteristics on Monte Carlo calculated absorbed dose distributions for linear accelerator electron beams
    Björk, P
    Knöös, T
    Nilsson, P
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (22): : 4019 - 4041
  • [24] Dose profile measurement using an imaging plate: Evaluation of filters using Monte Carlo simulation of 4 MV x-rays
    Hashimoto, Masatoshi
    Tomita, Tetsuya
    Sawada, Koichi
    Fujibuchi, Toshioh
    Nishio, Teiji
    Nakagawa, Keiichi
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (04):
  • [25] Heterogeneity corrected convolution dose calculation for KV X-rays versus Monte Carlo simulation
    Verhaegen, F
    Schulze, C
    Seuntjens, J
    Gosselin, M
    Hristov, D
    Svatos, M
    MEDICAL PHYSICS, 2004, 31 (06) : 1770 - 1770
  • [26] A study on scattered particles from medical linear accelerator head using monte carlo simulation
    Katayose, T. (u5856601@gs.metro-hs.ac.jp), (KEK High Energy Accelerator Research Organization):
  • [27] Measurement and Monte Carlo simulation of γ-ray dose rate in high-exposure building materials
    A. Abbasi
    M. Hassanzadeh
    Nuclear Science and Techniques, 2017, 28
  • [28] Measurement and Monte Carlo simulation of γ-ray dose rate in high-exposure building materials
    A.Abbasi
    M.Hassanzadeh
    Nuclear Science and Techniques, 2017, 28 (02) : 65 - 69
  • [29] Measurement and Monte Carlo simulation of γ-ray dose rate in high-exposure building materials
    Abbasi, A.
    Hassanzadeh, M.
    NUCLEAR SCIENCE AND TECHNIQUES, 2017, 28 (02)
  • [30] Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter
    Almberg, S. S.
    Frengen, J.
    Lindmo, T.
    MEDICAL PHYSICS, 2012, 39 (08) : 5194 - 5203