A frost-free dedicated outdoor air system with exhaust air heat recovery

被引:41
|
作者
Zhang, Zi-Yang [1 ]
Zhang, Chun-Lu [1 ]
Ge, Mei-Cai [2 ]
Yu, Yue [2 ]
机构
[1] Tongji Univ, Sch Mech Engn, Inst Refrigerat & Cryogen, Shanghai 201804, Peoples R China
[2] Nantong Huaxin Cent Air Conditioning CO LTD, Nantong 226014, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Dedicated outdoor air system; Heat pump; Exhaust air heat recovery; Frost-free; PERFORMANCE EVALUATION; ENERGY PERFORMANCE; LIQUID DESICCANT; OFFICE BUILDINGS; COOLING SYSTEM; EXCHANGERS; FLOW; PUMP; EFFICIENCY; TUBES;
D O I
10.1016/j.applthermaleng.2017.09.091
中图分类号
O414.1 [热力学];
学科分类号
摘要
DOAS (dedicated outdoor air system) has drawn much attention recently. However, it is quite energy intensive resulted from the big temperature and/or humidity difference between outdoor air and supply air. This paper proposed a new DOAS with exhaust air heat recovery. In cooling mode, there are one evaporator and three condensers in parallel. The outdoor air is cooled and dehumidified by the evaporator. Besides the outdoor condenser, another two are used for supply air reheat and exhaust air heat recovery. In heating mode, the reheat coil is off and two evaporators work for exhaust air heat recovery and ambient heat absorption, respectively. A pressure regulating valve equipped on the indoor evaporator keeps proper evaporating temperature for a frost-free operation. A validated model is applied to fulfill the system design and performance prediction. The results showed that the system cooling COP reaches 3.3 at ambient temperature 35 degrees C/28 degrees C and the heating COP achieves 4.8 at ambient temperature 7 degrees C/6 degrees C, respectively. In winter the proposed system can maintain the desired supply temperature and keep both evaporators frost-free (ambient temperature -20 degrees C to 10 degrees C). The proposed system can efficiently recover waste energy from exhaust air in the whole year and has the extensive applicability, especially in the cold climate where considerable energy savings can be found. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1041 / 1050
页数:10
相关论文
共 50 条
  • [41] Designing an air-to-air heat exchanger dedicated to single room ventilation with heat recovery
    Gendebien, Samuel
    Martens, Jonathan
    Prieels, Luc
    Lemort, Vincent
    BUILDING SIMULATION, 2018, 11 (01) : 103 - 113
  • [42] Performance evaluation of a novel frost-free air-source heat pump integrated with phase change materials (PCMs) and dehumidification
    Wang, Zhihua
    Wang, Fenghao
    Ma, Zhenjun
    Li, Chun
    Xu, Yibo
    IMPROVING RESIDENTIAL ENERGY EFFICIENCY INTERNATIONAL CONFERENCE, IREE 2017, 2017, 121 : 134 - 141
  • [43] Performance optimization of a frost-free air cooled refrigerator with series-parallel refrigeration cycle
    Hao G.
    Liu Y.
    Yan G.
    Yu J.
    Huagong Xuebao/CIESC Journal, 2021, 72 : 178 - 183
  • [45] A Integrated Dedicated Outdoor Air System to Optimize Energy Saving
    Chuah, Yew Khoy
    Yang, Jun Jie
    SUSTAINABILITY, 2020, 12 (03)
  • [46] Designing dedicated outdoor air systems
    Mumma, SA
    ASHRAE JOURNAL, 2001, 43 (05) : 28 - 31
  • [47] Dedicated outdoor air systems revisited
    Dieckmann, John
    Roth, Kurt
    Brodrick, James
    ASHRAE JOURNAL, 2007, 49 (12) : 127 - 129
  • [48] Introduction to dedicated outdoor air systems
    Stuart, Alexandria
    Johnson, Caley
    Consulting-Specifying Engineer, 2023, 60 (04) : 30 - 34
  • [49] Smart dedicated outdoor air systems
    Murphy, John
    ASHRAE JOURNAL, 2006, 48 (07) : 30 - +
  • [50] Performance investigation of a novel frost-free air-source heat pump water heater combined with energy storage and dehumidification
    Wang, Fenghao
    Wang, Zhihua
    Zheng, Yuxin
    Lin, Zhang
    Hao, Pengfei
    Huan, Chao
    Wang, Tian
    APPLIED ENERGY, 2015, 139 : 212 - 219