The Effect of Pinna Position on Body Temperature Measurements Made with a Tympanic Membrane Thermometer in Pediatric Patients

被引:2
|
作者
Orkun, Nilay [1 ]
Eser, Ismet [1 ]
机构
[1] Ege Univ, Dept Fundamentals Nursing, Fac Nursing, Izmir, Turkey
关键词
Body temperature; pediatric patient; tympanic membrane thermometer; pinna position; nursing practice; EAR; MERCURY;
D O I
10.4274/jpr.galenos.2019.33600
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Aim: The aim of this study was to investigate the effect of pinna position on body temperature measurements made with a tympanic membrane thermometer in pediatric patients. Materials and Methods: This study was conducted with a quasi-experimental design employing a pre-test and post-test. For analysis of the data, frequencies, percentages, means and standard deviations were calculated, and the significance of the difference between paired values was tested in order to investigate the effects of the auricle position on measurement values. Results: The age of the patients included in the study ranged between 6 and 13 years, and the mean age was 10.25 +/- 1.83 years. The mean difference between measurements in the two different positions was 0.35 degrees C. The measurements made in each position were represented in a Bland Altman plot. It was seen that the differences between the two positions were not distributed around zero, but instead showed a systematic distribution around 0.35 degrees C. There was a significant relationship between the differences and the mean values. The difference between the mean durations of the measurements was found to be 1.07 seconds longer with pinna positioning than without. The discomfort levels of the patients during temperature measurement without pinna positioning and with pinna positioning ranged between 0-2 and 0-4 according to the facial expressions scale respectively. During temperature measurement with pinna positioning and without pinna positioning, patients felt no discomfort. Conclusion: In measurements carried out using tympanic membrane thermometers in pediatric patients, positioning the auricle by pulling it downward posteriorly yielded more reliable and correct outcomes.
引用
收藏
页码:132 / 138
页数:7
相关论文
共 50 条
  • [41] Effect of Anesthesia Applied for Magnetic Resonance Imaging on the Body Temperature of Pediatric Patients
    Uludag, Oznur
    Kaya, Recai
    Tutak, Atilla
    Dogukan, Mevlut
    Celik, Mustafa
    Dumlupinar, Ebru
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (09)
  • [42] Prevalence of the Complications Related to the Foreign Body Patients (Laceration, Perforation of Tympanic Membrane and Bleeding)
    Latif, Abdul
    Zaman, Sher
    Amin, Gohar
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2018, 12 (03): : 1286 - 1288
  • [43] Comparing body temperature measurements by mothers and physicians using mercury-in-glass, digital mercury and infrared tympanic membrane thermometers in healthy newborn babies
    Cultu, Oege
    Yildirim, Inci
    Ceyhan, Mehmet
    Korkmaz, Ayse
    Yurdakoek, Murat
    Karaagaoglu, Ergun
    Secmeer, Guelten
    TURKISH JOURNAL OF PEDIATRICS, 2008, 50 (04) : 354 - 358
  • [44] Effect of body position on measurements of diffusion capacity after exercise
    Stewart, LB
    Potts, JE
    McKenzie, DC
    Coutts, KD
    BRITISH JOURNAL OF SPORTS MEDICINE, 2000, 34 (06) : 440 - 444
  • [45] An analysis of the effect of thermometer type and make on rectal temperature measurements of cattle, horses and sheep
    Hine, L.
    Laven, R. A.
    Sahu, S. K.
    NEW ZEALAND VETERINARY JOURNAL, 2015, 63 (03) : 171 - 173
  • [46] A Comparative Study of Non-contact Infrared and Digital Rectal Thermometer Measurements of Body Temperature in the Horse
    Ramey, David
    Bachmann, Kristin
    Lee, Martin L.
    JOURNAL OF EQUINE VETERINARY SCIENCE, 2011, 31 (04) : 191 - 193
  • [47] The effect of underclothing on percent body fat measurements made with the BOD POD
    Kaminsky, LA
    Hanni-Wells, J
    Whaley, MH
    Davis, RW
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (05): : S72 - S72
  • [48] Effect of Body Position on the Measurements of Early and Late Cardiac Repolarization Duration
    Handzel, R.
    Couderc, J. P.
    Xia, X.
    CINC: 2009 36TH ANNUAL COMPUTERS IN CARDIOLOGY CONFERENCE, 2009, 36 : 581 - +
  • [49] The effect of cervical inclination and body position on postmortem cephalometric airway measurements
    Tiihonen, M
    Heliovaara, A
    Partinen, M
    Pirinen, S
    Wolf, J
    Penttilä, A
    FORENSIC SCIENCE INTERNATIONAL, 1999, 103 (03) : 145 - 158
  • [50] Reliability of body temperature measurements in hospitalised older patients
    Giantin, Valter
    Toffanello, Elena D.
    Enzi, Giuliano
    Perissinotto, Egle
    Vangelista, Stefania
    Simonato, Matteo
    Ceccato, Corrado
    Manzato, Enzo
    Sergi, Giuseppe
    JOURNAL OF CLINICAL NURSING, 2008, 17 (11) : 1518 - 1525