The Effect of Pinna Position on Body Temperature Measurements Made with a Tympanic Membrane Thermometer in Pediatric Patients

被引:2
|
作者
Orkun, Nilay [1 ]
Eser, Ismet [1 ]
机构
[1] Ege Univ, Dept Fundamentals Nursing, Fac Nursing, Izmir, Turkey
关键词
Body temperature; pediatric patient; tympanic membrane thermometer; pinna position; nursing practice; EAR; MERCURY;
D O I
10.4274/jpr.galenos.2019.33600
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Aim: The aim of this study was to investigate the effect of pinna position on body temperature measurements made with a tympanic membrane thermometer in pediatric patients. Materials and Methods: This study was conducted with a quasi-experimental design employing a pre-test and post-test. For analysis of the data, frequencies, percentages, means and standard deviations were calculated, and the significance of the difference between paired values was tested in order to investigate the effects of the auricle position on measurement values. Results: The age of the patients included in the study ranged between 6 and 13 years, and the mean age was 10.25 +/- 1.83 years. The mean difference between measurements in the two different positions was 0.35 degrees C. The measurements made in each position were represented in a Bland Altman plot. It was seen that the differences between the two positions were not distributed around zero, but instead showed a systematic distribution around 0.35 degrees C. There was a significant relationship between the differences and the mean values. The difference between the mean durations of the measurements was found to be 1.07 seconds longer with pinna positioning than without. The discomfort levels of the patients during temperature measurement without pinna positioning and with pinna positioning ranged between 0-2 and 0-4 according to the facial expressions scale respectively. During temperature measurement with pinna positioning and without pinna positioning, patients felt no discomfort. Conclusion: In measurements carried out using tympanic membrane thermometers in pediatric patients, positioning the auricle by pulling it downward posteriorly yielded more reliable and correct outcomes.
引用
收藏
页码:132 / 138
页数:7
相关论文
共 50 条
  • [21] The effect of investigator gender on lateral tympanic membrane temperature
    Helton, William S.
    Carter, Jason R.
    LATERALITY, 2011, 16 (02): : 156 - 163
  • [22] Comparison of the accuracy of body temperature measurements with temporal artery thermometer and axillary mercury thermometer in term newborns
    Gunawan, Markus
    Soetjiningsih
    Kardana, I. Made
    PAEDIATRICA INDONESIANA, 2010, 50 (02) : 67 - 72
  • [23] A Novel Non-Invasive Thermometer for Continuous Core Body Temperature: Comparison with Tympanic Temperature in an Acute Stroke Clinical Setting
    Ajcevic, Milos
    Stella, Alex Buoite
    Furlanis, Giovanni
    Caruso, Paola
    Naccarato, Marcello
    Accardo, Agostino
    Manganotti, Paolo
    SENSORS, 2022, 22 (13)
  • [24] What Is the Optimal Age to Repair Tympanic Membrane Perforations in Pediatric Patients?
    Ryan, Marisa A.
    Kaylie, David M.
    LARYNGOSCOPE, 2016, 126 (10): : 2201 - 2202
  • [25] Temperature Measurements Comparison of different thermometer types for patients with cancer
    Gates, Deborah
    Horner, Victoria
    Bradley, Lindsey
    Sheperd, Takeya Fogle
    John, Omena
    Higgins, Melinda
    CLINICAL JOURNAL OF ONCOLOGY NURSING, 2018, 22 (06) : 611 - 617
  • [26] Axillary and tympanic membrane temperature measurements are unreliable early after cardiopulmonary bypass
    Khan, TA
    Vohra, HA
    Paul, S
    Rosin, MD
    Patel, RL
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (07) : 551 - 554
  • [27] EFFECT OF TACHYPNEA ON THE ESTIMATION OF BODY-TEMPERATURE BY AN ORAL THERMOMETER
    TANDBERG, D
    SKLAR, D
    NEW ENGLAND JOURNAL OF MEDICINE, 1983, 308 (16): : 945 - 946
  • [28] Correlation and agreement between infrared thermography and a thermometer for equine body temperature measurements
    Lampang, Kannika Na
    Isawirodom, Ashannut
    Rungsri, Porrakote
    VETERINARY WORLD, 2023, 16 (12) : 2464 - 2470
  • [29] A SIMPLE DOUBLE-BRIDGE THERMISTOR THERMOMETER FOR ACCURATE BODY TEMPERATURE MEASUREMENTS
    COLLINS, JC
    FOX, RH
    PLIMSAUL, G
    JOURNAL OF PHYSIOLOGY-LONDON, 1969, 203 (01): : P7 - &
  • [30] Clinical accuracy and agreement between tympanic and forehead body temperature measurements for screening of patients with COVID-19
    Nia, Hamid Sharif
    Chong, Pei Pei
    Huak, Chan Yiong
    Gorgulu, Ozkan
    Taghipour, Behzad
    Froelicher, Erika Sivarajan
    Sharif, Saeed Pahlevan
    Rahmatpour, Pardis
    JOURNAL OF CLINICAL NURSING, 2022, 31 (21-22) : 3272 - 3285