The Effect of Pinna Position on Body Temperature Measurements Made with a Tympanic Membrane Thermometer in Pediatric Patients

被引:2
|
作者
Orkun, Nilay [1 ]
Eser, Ismet [1 ]
机构
[1] Ege Univ, Dept Fundamentals Nursing, Fac Nursing, Izmir, Turkey
关键词
Body temperature; pediatric patient; tympanic membrane thermometer; pinna position; nursing practice; EAR; MERCURY;
D O I
10.4274/jpr.galenos.2019.33600
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Aim: The aim of this study was to investigate the effect of pinna position on body temperature measurements made with a tympanic membrane thermometer in pediatric patients. Materials and Methods: This study was conducted with a quasi-experimental design employing a pre-test and post-test. For analysis of the data, frequencies, percentages, means and standard deviations were calculated, and the significance of the difference between paired values was tested in order to investigate the effects of the auricle position on measurement values. Results: The age of the patients included in the study ranged between 6 and 13 years, and the mean age was 10.25 +/- 1.83 years. The mean difference between measurements in the two different positions was 0.35 degrees C. The measurements made in each position were represented in a Bland Altman plot. It was seen that the differences between the two positions were not distributed around zero, but instead showed a systematic distribution around 0.35 degrees C. There was a significant relationship between the differences and the mean values. The difference between the mean durations of the measurements was found to be 1.07 seconds longer with pinna positioning than without. The discomfort levels of the patients during temperature measurement without pinna positioning and with pinna positioning ranged between 0-2 and 0-4 according to the facial expressions scale respectively. During temperature measurement with pinna positioning and without pinna positioning, patients felt no discomfort. Conclusion: In measurements carried out using tympanic membrane thermometers in pediatric patients, positioning the auricle by pulling it downward posteriorly yielded more reliable and correct outcomes.
引用
收藏
页码:132 / 138
页数:7
相关论文
共 50 条
  • [1] EVALUATION OF AN INFRARED TYMPANIC MEMBRANE THERMOMETER IN PEDIATRIC-PATIENTS
    KENNEY, RD
    FORTENBERRY, JD
    SURRATT, SS
    RIBBECK, BM
    THOMAS, WJ
    PEDIATRICS, 1990, 85 (05) : 854 - 858
  • [2] Accuracy of tympanic temperature measurement using an infrared tympanic membrane thermometer
    Gasim G.I.
    Musa I.R.
    Abdien M.T.
    Adam I.
    BMC Research Notes, 6 (1)
  • [3] Accuracy of parents in measuring body temperature with a tympanic thermometer
    Robinson J.L.
    Jou H.
    Spady D.W.
    BMC Family Practice, 6 (1)
  • [4] Analysis of the effect of lying on the ear on body temperature measurement using a tympanic thermometer
    Arslan, Gulsah Gurol
    Eser, Ismet
    Khorshid, Leyla
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2011, 61 (11) : 1065 - 1068
  • [5] Intraoperative body temperature control: esophageal thermometer versus infrared tympanic thermometer
    Poveda, Vanessa de Brito
    Nascimento, Ariane de Souza
    REVISTA DA ESCOLA DE ENFERMAGEM DA USP, 2016, 50 (06) : 945 - 950
  • [6] Does central tympanic membrane perforation affect infrared tympanic thermometer measurements in adults?
    Hamdi Tasli
    Mert Cemal G?kg?z
    Journal of Otology, 2018, 13 (04) : 128 - 130
  • [7] Establishing the presence of a body temperature rhythm in chimpanzees (Pan troglodytes) using a tympanic membrane thermometer
    Fowler, LA
    Hopkins, WD
    Albers, HE
    Morris, RD
    Hyatt, CW
    PRIMATES, 1999, 40 (03) : 499 - 508
  • [8] Establishing the presence of a body temperature rhythm in chimpanzees (Pan troglodytes) using a tympanic membrane thermometer
    L. A. Fowler
    W. D. Hopkins
    H. E. Albers
    R. D. Morris
    C. W. Hyatt
    Primates, 1999, 40 : 499 - 508
  • [9] The effect of factors such as handedness, sex and age on body temperature measured by an infrared 'tympanic' thermometer
    School of Applied Science, University of Glamorgan, Mid Glamorgan, CF37 1DL, United Kingdom
    不详
    J. Med. Eng. Technol., 2006, 4 (235-241):
  • [10] Estimation of contact tympanic membrane temperature with a noncontact infrared thermometer
    Temdrup, TE
    Crofton, DJ
    Mortelliti, AJ
    Kelley, R
    Rajk, J
    ANNALS OF EMERGENCY MEDICINE, 1997, 30 (02) : 171 - 175