7 Tesla (T) human cardiovascular magnetic resonance imaging using FLASH and SSFP to assess cardiac function: validation against 1.5 T and 3 T.

被引:46
|
作者
Suttie, J. J. [1 ]
DelaBarre, L. [2 ]
Pitcher, A. [1 ]
van de Moortele, P. F. [2 ]
Dass, S. [1 ]
Snyder, C. J. [2 ]
Francis, J. M. [1 ]
Metzger, G. J. [2 ]
Weale, P. [3 ]
Ugurbil, K. [2 ]
Neubauer, S. [1 ]
Robson, M. [1 ]
Vaughan, T. [2 ]
机构
[1] Univ Oxford, Dept Cardiovasc Med, Ctr Clin Magnet Resonance Res, Oxford, England
[2] Univ Minnesota, Dept Radiol, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
[3] Siemens Healthcare, Cardiovasc MR Res & Dev, Chicago, IL USA
基金
英国医学研究理事会;
关键词
7; Tesla; high field strength; cardiovascular magnetic resonance imaging; cardiac function; clinical validation; MASS;
D O I
10.1002/nbm.1708
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We report the first comparison of cardiovascular magnetic resonance imaging (CMR) at 1.5T, 3T and 7T field strengths using steady state free precession (SSFP) and fast low angle shot (FLASH) cine sequences. Cardiac volumes and mass measurements were assessed for feasibility, reproducibility and validity at each given field strength using FLASH and SSFP sequences. Ten healthy volunteers underwent retrospectively electrocardiogram (ECG) gated CMR at 1.5T, 3T and 7T using FLASH and SSFP sequences. B1 and B0 shimming and frequency scouts were used to optimise image quality. Cardiac volume and mass measurements were not significantly affected by field strength when using the same imaging sequence (P>0.05 for all parameters at 1.5T, 3T and 7T). SSFP imaging returned larger end diastolic and end systolic volumes and smaller left ventricular masses than FLASH imaging at 7T, and at the lower field strengths (P<0.05 for each parameter). However, univariate general linear model analysis with fixed effects for sequence and field strengths found an interaction between imaging sequence and field strength (P=0.03), with a smaller difference in volumes and mass measurements between SSFP and FLASH imaging at 7T than 1.5T and 3T. SSFP and FLASH cine imaging at 7T is technically feasible and provides valid assessment of cardiac volumes and mass compared with CMR imaging at 1.5T and 3T field strengths. Copyright (c) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:27 / 34
页数:8
相关论文
共 50 条
  • [41] Cardiac magnetic resonance imaging using an open 0.35 T system
    Klein, Hans-Martin
    Meyners, Werner
    Neeb, Benjamin
    Labenz, Joachim
    Truemmler, Karl-Heinz
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (03) : 430 - 434
  • [42] Breast Magnetic Resonance Imaging Technique at 1.5 T and 3 T Requirements for Quality Imaging and American College of Radiology Accreditation
    DeMartini, Wendy B.
    Rahbar, Habib
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2013, 21 (03) : 475 - +
  • [43] Diffusion tensor magnetic resonance imaging of the human calf - Comparison between 1.5 T and 3.0 T - Preliminary results
    Saupe, Nadia
    White, Lawrence M.
    Sussman, Marshall S.
    Kassner, Andrea
    Tomlinson, George
    Noseworthy, Michael D.
    INVESTIGATIVE RADIOLOGY, 2008, 43 (09) : 612 - 618
  • [44] MAGNETIC RESONANCE IMAGING OF THE CANINE BRAIN AT 3 AND 7T
    Martin-Vaquero, Paula
    da Costa, Ronaldo C.
    Echandi, Rita L.
    Tosti, Christina L.
    Knopp, Michael V.
    Sammet, Steffen
    VETERINARY RADIOLOGY & ULTRASOUND, 2011, 52 (01) : 25 - 32
  • [45] Reference values for regional and global myocardial T2 mapping with cardiovascular magnetic resonance at 1.5T and 3T
    Alicia M Maceira
    Jose Vicente Monmeneu
    Begoña Igual-Muñoz
    Pilar M Lopez-Lereu
    Pilar M Garcia
    Juan Cosin
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [46] Visualization of the deep cerebellar nuclei using quantitative T1 and ρ magnetic resonance imaging at 3 Tesla
    Deoni, Sean C. L.
    Catani, Marco
    NEUROIMAGE, 2007, 37 (04) : 1260 - 1266
  • [47] T1 Relaxivities of Gadolinium-Based Magnetic Resonance Contrast Agents in Human Whole Blood at 1.5, 3, and 7 T
    Shen, Yaqi
    Goerner, Frank L.
    Snyder, Christopher
    Morelli, John N.
    Hao, Dapeng
    Hu, Daoyu
    Li, Xiaoming
    Runge, Val M.
    INVESTIGATIVE RADIOLOGY, 2015, 50 (05) : 330 - 338
  • [48] Using T1 mapping in cardiovascular magnetic resonance to assess congestive hepatopathy
    Isabel Kazour
    Suraj D. Serai
    Stavra A. Xanthakos
    Robert J. Fleck
    Abdominal Radiology, 2018, 43 : 2679 - 2685
  • [49] Broadband Transmit/Receive Switch for 3T and 7T Magnetic Resonance Imaging
    Abuelhaija, Ashraf
    Saleh, Gameel
    Salama, Sanaa
    Hamdan, Mohammed
    JOURNAL OF ELECTROMAGNETIC ENGINEERING AND SCIENCE, 2024, 24 (03): : 243 - 253
  • [50] Using T1 mapping in cardiovascular magnetic resonance to assess congestive hepatopathy
    Kazour, Isabel
    Serai, Suraj D.
    Xanthakos, Stavra A.
    Fleck, Robert J.
    ABDOMINAL RADIOLOGY, 2018, 43 (10) : 2679 - 2685