The Probability Increasing of the Low-Contrast Structures Detection in X-Ray Images by Using the Software that Enhances the Contrast and Signal/Noise Ratio

被引:0
|
作者
Miroshnichenko, N. [1 ]
机构
[1] Prod Res Assoc Teleopt, Kiev, Ukraine
关键词
software image processing; absorbed dose; chest examination; digital image processing; X-ray image; image contract; patient dose; chest screening; signal/noise ratio; water phantom; low-contrast object;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
It was discussed the necessity to use processing software for X-ray images. It was discussed the relevance of such work for children studies. Experiments were carried out on a water phantom, simulating of the child chest, at voltage range 40 ... 100 kV and exposure 1 ... 3 mAs. The resulting image were processed by software with blocks increasing the contrast and noise reduction. Obtained results suggest the possibility of reducing the voltages and doses for children examination without compromising the quality image.
引用
收藏
页码:389 / 392
页数:4
相关论文
共 50 条
  • [1] DETECTION OF LOW-CONTRAST IMAGES IN FILM-GRAIN NOISE
    NADERI, F
    SAWCHUK, AA
    APPLIED OPTICS, 1978, 17 (18): : 2883 - 2891
  • [2] Motion measurements in low-contrast X-ray imagery
    Berger, M
    Gerig, G
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI'98, 1998, 1496 : 832 - 841
  • [3] Low-Contrast Detectability for X-Ray Computed Tomography
    Hsieh, J.
    Toth, T.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [4] Quantitative Analysis of Contrast to Noise Ratio Using a Phase Contrast X-ray Imaging Prototype
    Ghani, Muhammad U.
    Wu, Di
    Li, Yuhua
    Kang, Minhua
    Chen, Wei R.
    Wu, Xizeng
    Liu, Hong
    BIOPHOTONICS AND IMMUNE RESPONSES VIII, 2013, 8582
  • [5] Low-contrast X-ray enhancement using a fuzzy gamma reasoning model
    Mouzai, Meriem
    Tarabet, Chahrazed
    Mustapha, Aouache
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2020, 58 (06) : 1177 - 1197
  • [6] Optimum phase condition for low-contrast X-ray masks
    Fujii, K
    Suzuki, K
    Matsui, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1999, 38 (12B): : 7076 - 7079
  • [7] Optimum phase condition for low-contrast X-ray masks
    Fujii, Kiyoshi
    Suzuki, Katsumi
    Matsui, Yasuji
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 1999, 38 (12 B): : 7076 - 7079
  • [8] Low-contrast X-ray enhancement using a fuzzy gamma reasoning model
    Meriem Mouzai
    Chahrazed Tarabet
    Aouache Mustapha
    Medical & Biological Engineering & Computing, 2020, 58 : 1177 - 1197
  • [9] Wavelet analysis of X-ray images with low signal/noise ratio
    Efimov, V. G.
    NONDESTRUCTIVE TESTING AND EVALUATION, 2005, 20 (01) : 35 - 42
  • [10] STATISTICAL METHOD OF ESTIMATING THE DETECTABILITY OF SMALL AND LOW-CONTRAST DETAILS IN X-RAY IMAGES.
    Gurvich, V.A.
    The Soviet journal of nondestructive testing, 1983, 19 (06): : 450 - 453