The Probability Increasing of the Low-Contrast Structures Detection in X-Ray Images by Using the Software that Enhances the Contrast and Signal/Noise Ratio

被引:0
|
作者
Miroshnichenko, N. [1 ]
机构
[1] Prod Res Assoc Teleopt, Kiev, Ukraine
关键词
software image processing; absorbed dose; chest examination; digital image processing; X-ray image; image contract; patient dose; chest screening; signal/noise ratio; water phantom; low-contrast object;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
It was discussed the necessity to use processing software for X-ray images. It was discussed the relevance of such work for children studies. Experiments were carried out on a water phantom, simulating of the child chest, at voltage range 40 ... 100 kV and exposure 1 ... 3 mAs. The resulting image were processed by software with blocks increasing the contrast and noise reduction. Obtained results suggest the possibility of reducing the voltages and doses for children examination without compromising the quality image.
引用
收藏
页码:389 / 392
页数:4
相关论文
共 50 条
  • [21] Analysis of x-ray reflectivity data from low-contrast polymer bilayer systems using a Fourier method
    Seeck, OH
    Kaendler, ID
    Tolan, M
    Shin, K
    Rafailovich, MH
    Sokolov, J
    Kolb, R
    APPLIED PHYSICS LETTERS, 2000, 76 (19) : 2713 - 2715
  • [22] Analysis of X-ray reflectivity data from low-contrast polymer bilayer systems using a Fourier method
    Seeck, O.H.
    Kaendler, I.D.
    Tolan, M.
    Shin, K.
    Rafailovich, M.H.
    Sokolov, J.
    Kolb, R.
    2000, American Inst of Physics, Woodbury, NY, USA (76)
  • [23] Improved Contrast in Images of Exoplanets Using Direct Signal-to-noise Ratio Optimization
    Thompson, William
    Marois, Christian
    ASTRONOMICAL JOURNAL, 2021, 161 (05):
  • [24] SUB-0.15 MU-M PATTERN REPLICATION USING A LOW-CONTRAST X-RAY MASK
    KIKUCHI, Y
    NOMURA, H
    HIGASHIKAWA, I
    GOMEI, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1994, 33 (12B): : 6928 - 6934
  • [25] Dose efficiency and low-contrast detectability of an amorphous silicon x-ray detector for digital radiography
    Aufrichtig, R
    Xue, P
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09): : 2653 - 2669
  • [26] Increasing the darkfield contrast-to-noise ratio using a deconvolution-based information retrieval algorithm in X-ray grating-based phase-contrast imaging
    Weber, Thomas
    Pelzer, Georg
    Bayer, Florian
    Horn, Florian
    Rieger, Jens
    Ritter, Andre
    Zang, Andrea
    Durst, Juergen
    Anton, Gisela
    Michel, Thilo
    OPTICS EXPRESS, 2013, 21 (15): : 18011 - 18020
  • [27] Picosecond-resolved X-ray absorption spectroscopy at low signal contrast using a hard X-ray streak camera
    Adams, Bernhard W.
    Rose-Petruck, Christoph
    Jiao, Yishuo
    JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 1022 - 1029
  • [28] FACTORS AFFECTING THE APPEARANCE OF LOW-CONTRAST MICRO-OBJECTS ON PHOTOGRAPHS AND X-RAY PICTURES
    GRISHIN, MP
    ZHURNAL NAUCHNOI I PRIKLADNOI FOTOGRAFII, 1994, 39 (06): : 57 - 59
  • [29] X-ray elastography: Modification of x-ray phase contrast images using ultrasonic radiation pressure
    Hamilton, Theron J.
    Bailat, Claude
    Gehring, Stephan
    Laperle, Christopher M.
    Wands, Jack
    Rose-Petruck, Christoph
    Diebold, Gerald J.
    Journal of Applied Physics, 2009, 105 (10):
  • [30] Salient object detection using a covariance-based CNN model in low-contrast images
    Mu, Nan
    Xu, Xin
    Zhang, Xiaolong
    Zhang, Hong
    NEURAL COMPUTING & APPLICATIONS, 2018, 29 (08): : 181 - 192