Low-contrast X-ray enhancement using a fuzzy gamma reasoning model

被引:10
|
作者
Mouzai, Meriem [1 ]
Tarabet, Chahrazed [1 ]
Mustapha, Aouache [1 ]
机构
[1] CDTA, Div Telecom, POB 17, Algiers 16303, Algeria
关键词
X-ray; Enhancement; Fuzzy logic; Gamma correction; Statistical measurement; DL scatter; BONE-AGE ASSESSMENT; IMAGE; DESIGN; SYSTEM;
D O I
10.1007/s11517-020-02122-y
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
X-ray images play an important role in providing physicians with satisfactory information correlated to fractures and diseases; unfortunately, most of these images suffer from low contrast and poor quality. Thus, enhancement of the image will increase the accuracy of correct information on pathologies for an autonomous diagnosis system. In this paper, a new approach for low-contrast X-ray image enhancement based on brightness adjustment using a fuzzy gamma reasoning model (FGRM) is proposed. To achieve this, three phases are considered: pre-processing, Fuzzy model for adaptive gamma correction (GC), and quality assessment based on blind reference. The proposed approach's accuracy is examined through two different blind reference approaches based on statistical measures (BR-SM) and dispersion-location (BR-DL) descriptors, supported by resulting images. Experimental results of the proposed FGRM approach on three databases (cervical, lumbar, and hand radiographs) yield favorable results in terms of contrast adjustment and providing satisfactory quality images.
引用
收藏
页码:1177 / 1197
页数:21
相关论文
共 50 条
  • [1] Low-contrast X-ray enhancement using a fuzzy gamma reasoning model
    Meriem Mouzai
    Chahrazed Tarabet
    Aouache Mustapha
    Medical & Biological Engineering & Computing, 2020, 58 : 1177 - 1197
  • [2] Motion measurements in low-contrast X-ray imagery
    Berger, M
    Gerig, G
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI'98, 1998, 1496 : 832 - 841
  • [3] Low-Contrast Detectability for X-Ray Computed Tomography
    Hsieh, J.
    Toth, T.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [4] Optimum phase condition for low-contrast X-ray masks
    Fujii, K
    Suzuki, K
    Matsui, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1999, 38 (12B): : 7076 - 7079
  • [5] Optimum phase condition for low-contrast X-ray masks
    Fujii, Kiyoshi
    Suzuki, Katsumi
    Matsui, Yasuji
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 1999, 38 (12 B): : 7076 - 7079
  • [6] When will Low-Contrast Features be Visible in a STEM X-Ray Spectrum Image?
    Parish, Chad M.
    MICROSCOPY AND MICROANALYSIS, 2015, 21 (03) : 706 - 724
  • [7] Defect detection in X-ray images using fuzzy reasoning
    Lashkia, V
    IMAGE AND VISION COMPUTING, 2001, 19 (05) : 261 - 269
  • [8] The Probability Increasing of the Low-Contrast Structures Detection in X-Ray Images by Using the Software that Enhances the Contrast and Signal/Noise Ratio
    Miroshnichenko, N.
    2015 IEEE 35TH INTERNATIONAL CONFERENCE ON ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2015, : 389 - 392
  • [9] Analysis of x-ray reflectivity data from low-contrast polymer bilayer systems using a Fourier method
    Seeck, OH
    Kaendler, ID
    Tolan, M
    Shin, K
    Rafailovich, MH
    Sokolov, J
    Kolb, R
    APPLIED PHYSICS LETTERS, 2000, 76 (19) : 2713 - 2715
  • [10] Analysis of X-ray reflectivity data from low-contrast polymer bilayer systems using a Fourier method
    Seeck, O.H.
    Kaendler, I.D.
    Tolan, M.
    Shin, K.
    Rafailovich, M.H.
    Sokolov, J.
    Kolb, R.
    2000, American Inst of Physics, Woodbury, NY, USA (76)