Randomised methodology development study to investigate plaque removal efficacy of manual toothbrushes

被引:6
|
作者
Grimaldi, Roberta [1 ]
Yonel, Zehra [2 ]
Chapple, Iain [3 ]
Butler, Andrew [1 ]
Hall, Claire [3 ]
Reinbold, Klaus [4 ]
Mantzourani, Maria [1 ]
机构
[1] GSK Consumer Healthcare, St Georges Ave, Weybridge KT13 0DE, Surrey, England
[2] Univ Birmingham, Coll Med & Dent Sci, Inst Clin Sci, Birmingham, W Midlands, England
[3] Raven Lane Consulting Ltd, Wirral, Merseyside, England
[4] GSK Consumer Healthcare, Oral & Skin Hlth, St Georges Ave, Weybridge KT13 0DE, Surrey, England
关键词
Dental plaque control; Dental plaque index; Toothbrushing efficacy; In vivo; TRIALS;
D O I
10.1016/j.jdent.2021.103830
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study aimed to evaluate plaque removal efficacy of toothbrushes to guide clinical model development. Methods: This single-centre, randomised, controlled, examiner-blind, method development study included 80 healthy participants. Over 28 days, participants brushed twice-daily using a fluoride toothpaste and one of four marketed toothbrushes: Toothbrushes A (compact head) and B (regular head): medium-hard; flat trim; end rounded bristles; Toothbrush C: medium-hard; end-rounded bristles; silky, tapered filaments; compact head; Toothbrush D: soft; tapered filaments; compact head. Supra-gingival plaque removal was evaluated immediately after single brushing events (Days 0, 7, 28, at study centre) and following 7and 28-days' home use via Rustogi modified Navy Plaque Index (RPI) and Turesky modified Quigley Hein Plaque Index (TPI). Results: All toothbrushes provided significant plaque removal after single-brushing events with change from Day 0 pre-brushing scores on RPI ranging from-0.10 to-0.16 (p<.0001) and on TPI ranging from-0.61 to-0.89 (p<.0001). Toothbrushes A and B showed significant (p<.05) pre-brushing RPI/TPI plaque reductions after 7(-0.04/-0.06, respectively for RPI;-0.16/-0.20, respectively for TPI) and 28-days (-0.04/-0.03, respectively for RPI;-0.20/-0.11, respectively for TPI) use versus Day 0 pre-brushing (except Toothbrush B, Day 28, nonsignificant TPI). There were no significant differences with Toothbrush C. Toothbrush D TPI was significantly lower at both timepoints versus Day 0 pre-brushing (p<.05). Study toothbrushes were generally well-tolerated. Conclusion: The observations from this study showed how various aspects of a study design could impact toothbrushes performance. These data will inform the design of future clinical studies of plaque removal efficacy using manual toothbrushes. Clinical Significance Statement: Regular effective oral hygiene can help prevent and treat gingivitis, principally via twice-daily mechanical cleaning with a toothbrush. Data generated from this methodology development study will help to identify the key aspects which impact toothbrushes' performance and understand which one would be more suitable to answer questions of scientific interest. This study provides useful information for the design of future clinical trials to assess plaque removal efficacy of manual toothbrushes and generate results to inform clinical recommendations.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Plaque removal efficacy of two counter-rotational electric toothbrushes.
    De Jager, M
    Wiedemann, W
    Klinger, H
    Melzer, B
    Sturm, D
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 664 - 664
  • [32] Plaque removal efficacy of two electric toothbrushes with different brush head designs
    Sharma, NC
    Qaqish, JG
    Galustians, HJ
    Goyal, CR
    Cugini, MA
    Thompson, MC
    Warren, PR
    JOURNAL OF DENTISTRY, 2005, 33 : 17 - 21
  • [33] Impact of manual toothbrush design on plaque removal efficacy
    Axe, Alyson
    Mueller, Wolf Dieter
    Rafferty, Helen
    Lang, Tomas
    Gaengler, Peter
    BMC ORAL HEALTH, 2023, 23 (01)
  • [34] PLAQUE REMOVAL EFFICACY OF MANUAL TOOTHBRUSH WITH MICROPULSE BRISTLES
    Dorter, Can
    Ulu, Oya
    Yaman, Batu Can
    Efes, Begum Guray
    Gomec, Yavuz
    Cilingir, Aylin
    Koray, Fatma
    JOURNAL OF ISTANBUL UNIVERSITY FACULTY OF DENTISTRY, 2010, 44 (02) : 81 - 87
  • [35] Impact of manual toothbrush design on plaque removal efficacy
    Alyson Axe
    Wolf Dieter Mueller
    Helen Rafferty
    Tomas Lang
    Peter Gaengler
    BMC Oral Health, 23
  • [36] Comparing Efficacy of Plaque Removal Using Professionally Applied Manual and Power Toothbrushes in 4- to 7-year-old Children
    Taschner, Michael
    Rumi, Kathrin
    Master, Aditi S.
    Wei, Jingling
    Strate, Joerg
    Pelka, Matthias
    PEDIATRIC DENTISTRY, 2012, 34 (01) : 61 - 65
  • [37] Comparative professional plaque removal study using 8 branded toothbrushes
    Claydon, N
    Addy, M
    Scratcher, C
    Ley, F
    Newcombe, R
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2002, 29 (04) : 310 - 316
  • [38] Dental Plaque Removal with Two Special Needs Toothbrushes in Patients with Down Syndrome: A Parallel-Group Randomised Clinical Trial of Efficacy
    Fageeha, Hytham N.
    Mansourb, Manawar A.
    Fageehb, Hammam I.
    Hummadid, Abdulkareem
    Khurayzid, Turki
    Marrand, Khalil
    Alqunfuthid, Naif
    Patile, Shankargouda
    ORAL HEALTH & PREVENTIVE DENTISTRY, 2022, 20 (01) : 501 - 508
  • [39] Efficacy of two soft-bristle toothbrushes in plaque removal: a randomized controlled trial
    Rosing, Cassiano Kuchenbecker
    Cavagni, Juliano
    Gaio, Eduardo Jose
    Mustafa Gomes Muniz, Francisco Wilker
    Rivera Oballe, Harry Juan
    Ranzan, Nicolle
    Friedrich, Stephanie Anagnostopoulos
    Severo, Raisa Maldonado
    Gittins, Elizabeth
    Stewart, Bernal
    Zhang, Yun Po
    BRAZILIAN ORAL RESEARCH, 2016, 30 (01):
  • [40] Randomised clinical study of plaque removal efficacy of a power toothbrush in a paediatric population
    Davidovich, Esti
    Ccahuana-Vasquez, Renzo Alberto
    Timm, Hans
    Grender, Julie
    Cunningham, Pam
    Zini, Avi
    INTERNATIONAL JOURNAL OF PAEDIATRIC DENTISTRY, 2017, 27 (06) : 558 - 567