Pre-operative templating in THA using a short stem system: precision and accuracy of 2D versus 3D planning method

被引:19
|
作者
Reinbacher, Patrick [1 ]
Smolle, Maria Anna [1 ]
Friesenbichler, Joerg [1 ]
Draschl, Alexander [1 ]
Leithner, Andreas [1 ]
Maurer-Ertl, Werner [1 ]
机构
[1] Med Univ Graz, Dept Orthopaed & Trauma, Auenbruggerpl 5, A-8036 Graz, Austria
关键词
Total hip arthroplasty; Templating; Short stem; 2D; 3D; TOTAL HIP-ARTHROPLASTY; COMPUTED-TOMOGRAPHY; KNEE REPLACEMENT; REVISION; RISK; MORTALITY; SOFTWARE; OBESITY;
D O I
10.1186/s10195-022-00634-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Total hip arthroplasty (THA) is the most successful orthopaedic surgery of the past century. The current study aimed to compare the accuracy of digital planning using 2D versus 3D templating. Materials and methods Ninety-five THAs in 90 patients were included in the current study. Pre- and post-operative X-rays (in two planes) and low-dose rotation computed tomography scans from hip to foot were performed. Paired t-test and regression analyses were conducted to compare 2D and 3D templating accuracy of the definitive implant. Results Cup size planned both with 2D (p < 0.0001) and 3D (p = 0.012) templating was significantly different from the definitively used cup size. The difference between the 2D-planned and implanted stem size (p < 0.0001) was statistically significant. In contrast, there were no significant differences in the 3D-planned and implanted stem size (p = 0.181). Three-dimensional templating showed significantly higher accuracy than 2D templating in terms of cup size (1.1 +/- 1.4 versus 1.7 +/- 1.8; p = 0.007) and stem size (0.3 +/- 0.6 versus 0.7 +/- 0.7; p < 0.0001). With increasing body mass index (BMI), 2D templating of the stem became more inaccurate (p = 0.041). Remarkably, 3D templating remained accurate for all components (stem, p = 0.533; cup, p = 0.479) despite increasing BMI. Conclusion Despite extended planning time and increased exposure to radiation, 3D-based planning showed higher accuracy than 2D templating, especially in obese patients. On the basis of our results, we believe that 3D-based pre-operative planning in THA is justifiable and beneficial in patients with increased BMI.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Do the sizes of total hip arthroplasty implants match between 3D planning software and 2D templating?
    Pansard, Erwan
    Vigan, Marie
    Bauer, Thomas
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2024, 110 (02)
  • [32] COMPARISON OF 3D PROSTATE VIRTUAL RENDERINGS WITH STANDARD MRI IMAGING IN PROSTATE CANCER PRE-OPERATIVE PLANNING
    Saba, Patrick
    Melnyk, Rachel
    Holler, Tyler
    Oppenheimer, Daniel
    Tabayoyong, William
    Bloom, Jonathan
    Bandari, Jathin
    Frye, Thomas
    Joseph, Jean
    Weinberg, Eric
    Hollenberg, Gary
    Ghazi, Ahmed
    JOURNAL OF UROLOGY, 2021, 206 : E395 - E395
  • [33] Using 3D Scanning Technology To Document The Pre-Operative Bariatric Patient: Automatic Measurement Extraction Versus The Tape Measure
    Wohlgemuth, Stephen
    Stefan, David B.
    OBESITY SURGERY, 2010, 20 (08) : 986 - 987
  • [34] Endoscopic navigation system using 2D/3D registration
    Hummel, Johann
    Figl, Michael
    Bergmann, Helmar
    Birkfellner, Wolfgang
    MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [35] Combined Computer-Aided and 3D Printing Technology for Pre-Operative Planning in Spine Fracture Surgery
    Chen, Pei-Jarn
    Weng, Jui-Yu
    Kuo, Jinn-Rung
    PROCEEDINGS OF 4TH IEEE INTERNATIONAL CONFERENCE ON APPLIED SYSTEM INNOVATION 2018 ( IEEE ICASI 2018 ), 2018, : 793 - 796
  • [36] Accuracy of 3D/3D and 3D/2D Registration in Intracranial Radiosurgery Using 6DOF Robotic Couch
    Kuo, H.
    Berry, S.
    Ballangrud, A.
    Atwal, P. S.
    Della Biancia, C.
    Pathare, P.
    Shasha, D.
    Lovelock, D.
    Hunt, M.
    MEDICAL PHYSICS, 2018, 45 (06) : E436 - E436
  • [37] DOES 3D VERSUS 2D PLANNING TECHNIQUES MAKE A DIFFERENCE IN PALLIATIVE RADIOTHERAPY?
    Pope, K.
    Holwell, M.
    Fitzpatrick, D.
    Potter, A.
    Bezjak, A.
    McLean, M.
    Levin, W.
    Lau, M.
    Wang, L.
    Zurawel-Balaura, L.
    Wong, R.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S63 - S64
  • [38] 2D and 3D Flexible Laser System for Precision Cutting, Welding and Drilling Applications
    Naeem, M.
    Montello, A.
    PROCEEDINGS OF THE 38TH INTERNATIONAL MATADOR CONFERENCE, 2022, : 175 - 189
  • [39] Which stem in total hip arthroplasty for developmental hip dysplasia? A comparative study using a 3D CT-based software for pre-operative surgical planning
    Castagnini, Francesco
    Lucchini, Stefano
    Bordini, Barbara
    Cosentino, Monica
    Pardo, Francesco
    Traina, Francesco
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2022, 23 (01)
  • [40] Which stem in total hip arthroplasty for developmental hip dysplasia? A comparative study using a 3D CT-based software for pre-operative surgical planning
    Francesco Castagnini
    Stefano Lucchini
    Barbara Bordini
    Monica Cosentino
    Francesco Pardo
    Francesco Traina
    Journal of Orthopaedics and Traumatology, 2022, 23