Pre-operative templating in THA using a short stem system: precision and accuracy of 2D versus 3D planning method

被引:19
|
作者
Reinbacher, Patrick [1 ]
Smolle, Maria Anna [1 ]
Friesenbichler, Joerg [1 ]
Draschl, Alexander [1 ]
Leithner, Andreas [1 ]
Maurer-Ertl, Werner [1 ]
机构
[1] Med Univ Graz, Dept Orthopaed & Trauma, Auenbruggerpl 5, A-8036 Graz, Austria
关键词
Total hip arthroplasty; Templating; Short stem; 2D; 3D; TOTAL HIP-ARTHROPLASTY; COMPUTED-TOMOGRAPHY; KNEE REPLACEMENT; REVISION; RISK; MORTALITY; SOFTWARE; OBESITY;
D O I
10.1186/s10195-022-00634-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Total hip arthroplasty (THA) is the most successful orthopaedic surgery of the past century. The current study aimed to compare the accuracy of digital planning using 2D versus 3D templating. Materials and methods Ninety-five THAs in 90 patients were included in the current study. Pre- and post-operative X-rays (in two planes) and low-dose rotation computed tomography scans from hip to foot were performed. Paired t-test and regression analyses were conducted to compare 2D and 3D templating accuracy of the definitive implant. Results Cup size planned both with 2D (p < 0.0001) and 3D (p = 0.012) templating was significantly different from the definitively used cup size. The difference between the 2D-planned and implanted stem size (p < 0.0001) was statistically significant. In contrast, there were no significant differences in the 3D-planned and implanted stem size (p = 0.181). Three-dimensional templating showed significantly higher accuracy than 2D templating in terms of cup size (1.1 +/- 1.4 versus 1.7 +/- 1.8; p = 0.007) and stem size (0.3 +/- 0.6 versus 0.7 +/- 0.7; p < 0.0001). With increasing body mass index (BMI), 2D templating of the stem became more inaccurate (p = 0.041). Remarkably, 3D templating remained accurate for all components (stem, p = 0.533; cup, p = 0.479) despite increasing BMI. Conclusion Despite extended planning time and increased exposure to radiation, 3D-based planning showed higher accuracy than 2D templating, especially in obese patients. On the basis of our results, we believe that 3D-based pre-operative planning in THA is justifiable and beneficial in patients with increased BMI.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] 3D versus 2D steering in patient anatomies: A comparison using hyperthermia treatment planning
    De Greef, M.
    Kok, H. P.
    Bel, A.
    Crezee, J.
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2011, 27 (01) : 74 - 85
  • [22] Comparison of the accuracy of 2D and 3D templating methods for planning primary total hip replacement: a systematic review and meta-analysis
    Bishi, Habeeb
    Smith, Joshua B., V
    Asopa, Vipin
    Field, Richard E.
    Sochart, David H.
    Wang, Chao
    EFORT OPEN REVIEWS, 2022, 7 (01) : 70 - 83
  • [23] Evaluation of the Rotational Alignment Accuracy and Error Using 3D/3D, 2D/3D and 3D Surface Registration
    Kuo, H.
    Ballangrud, A.
    Li, G.
    Lovelock, D.
    Wolthuis, B.
    Della-Biancia, C.
    Berry, S.
    Hunt, M.
    MEDICAL PHYSICS, 2019, 46 (06) : E307 - E308
  • [24] Validating 3D face morphing towards improving pre-operative planning in facial reconstruction surgery
    Fishman, Z.
    Liu, Jerry
    Pope, Joshua
    Fialkov, J. A.
    Whyne, C. M.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2021, 9 (05): : 480 - 487
  • [25] Pre-Operative 3D CT Imaging for Virtual Planning of Minimally Invasive Aortic Valve Surgery
    Loor, Gabriel
    Desai, Milind Y.
    Roselli, Eric E.
    JACC-CARDIOVASCULAR IMAGING, 2013, 6 (02) : 269 - 271
  • [26] Accuracy of Preoperative 3D vs 2D Digital Templating for Cementless Total Hip Arthroplasty Using a Direct Anterior Approach
    Aubert, Thomas
    Galanzino, Giacomo
    Gerard, Philippe
    Le Strat, Vincent
    Rigoulot, Guillaume
    Lhotellier, Luc
    ARTHROPLASTY TODAY, 2023, 24
  • [27] EStability and accuracy of 3D neutron transport simulations using the 2D/1D method in MPACT
    Collins, Benjamin
    Stimpson, Shane
    Kelley, Blake W.
    Young, Mitchell T. H.
    Kochunas, Brendan
    Graham, Aaron
    Larsen, Edward W.
    Downar, Thomas
    Godfrey, Andrew
    JOURNAL OF COMPUTATIONAL PHYSICS, 2016, 326 : 612 - 628
  • [28] A COMPARISON OF TOXICITIES IN CERVICAL CANCER PATIENTS TREATED USING 2D VERSUS 3D BRACHYTHERAPY PLANNING
    Abdullah, T.
    Chitoni, M.
    Reed, N.
    Harrand, R.
    Graham, K.
    Sadozye, A.
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2015, 25 (09) : 911 - 911
  • [29] Kinematic registration in 3D using the 2D Reuleaux method
    Eberharter, JK
    Ravani, B
    JOURNAL OF MECHANICAL DESIGN, 2006, 128 (02) : 349 - 355
  • [30] 3D versus 2D ultrasound - Accuracy of volume measurement in human cadaver kidneys
    Partik, BL
    Stadler, A
    Schamp, S
    Koller, A
    Voracek, M
    Heinz, G
    Helbich, TH
    INVESTIGATIVE RADIOLOGY, 2002, 37 (09) : 489 - 495