Pre-operative templating in THA using a short stem system: precision and accuracy of 2D versus 3D planning method

被引:19
|
作者
Reinbacher, Patrick [1 ]
Smolle, Maria Anna [1 ]
Friesenbichler, Joerg [1 ]
Draschl, Alexander [1 ]
Leithner, Andreas [1 ]
Maurer-Ertl, Werner [1 ]
机构
[1] Med Univ Graz, Dept Orthopaed & Trauma, Auenbruggerpl 5, A-8036 Graz, Austria
关键词
Total hip arthroplasty; Templating; Short stem; 2D; 3D; TOTAL HIP-ARTHROPLASTY; COMPUTED-TOMOGRAPHY; KNEE REPLACEMENT; REVISION; RISK; MORTALITY; SOFTWARE; OBESITY;
D O I
10.1186/s10195-022-00634-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Total hip arthroplasty (THA) is the most successful orthopaedic surgery of the past century. The current study aimed to compare the accuracy of digital planning using 2D versus 3D templating. Materials and methods Ninety-five THAs in 90 patients were included in the current study. Pre- and post-operative X-rays (in two planes) and low-dose rotation computed tomography scans from hip to foot were performed. Paired t-test and regression analyses were conducted to compare 2D and 3D templating accuracy of the definitive implant. Results Cup size planned both with 2D (p < 0.0001) and 3D (p = 0.012) templating was significantly different from the definitively used cup size. The difference between the 2D-planned and implanted stem size (p < 0.0001) was statistically significant. In contrast, there were no significant differences in the 3D-planned and implanted stem size (p = 0.181). Three-dimensional templating showed significantly higher accuracy than 2D templating in terms of cup size (1.1 +/- 1.4 versus 1.7 +/- 1.8; p = 0.007) and stem size (0.3 +/- 0.6 versus 0.7 +/- 0.7; p < 0.0001). With increasing body mass index (BMI), 2D templating of the stem became more inaccurate (p = 0.041). Remarkably, 3D templating remained accurate for all components (stem, p = 0.533; cup, p = 0.479) despite increasing BMI. Conclusion Despite extended planning time and increased exposure to radiation, 3D-based planning showed higher accuracy than 2D templating, especially in obese patients. On the basis of our results, we believe that 3D-based pre-operative planning in THA is justifiable and beneficial in patients with increased BMI.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Pre-operative templating in THA using a short stem system: precision and accuracy of 2D versus 3D planning method
    Patrick Reinbacher
    Maria Anna Smolle
    Joerg Friesenbichler
    Alexander Draschl
    Andreas Leithner
    Werner Maurer-Ertl
    Journal of Orthopaedics and Traumatology, 2022, 23
  • [2] 2D versus 3D templating in total knee arthroplasty
    Ettinger, Max
    Claassen, Leif
    Paes, Peter
    Calliess, Tilman
    KNEE, 2016, 23 (01): : 149 - 151
  • [3] Development of a model of 3D imaging for the pre-operative planning of TaTME
    Sahnan, K.
    Pellino, G.
    Adegbola, S. O.
    Tozer, P. J.
    Chandrasinghe, P.
    Misovikc, D.
    Hompes, R.
    Hart, A. L.
    Warusavitarne, J.
    Lung, P. F.
    JOURNAL OF CROHNS & COLITIS, 2018, 12 : S426 - S426
  • [4] Surgeons' perspectives on the use of 3D models for pre-operative planning
    Chan, T. C. T.
    Ng, C. M.
    Li, T. C. F.
    Kan, R. W. M.
    Kan, C. F.
    Chung, C. T.
    Stone, Y. H.
    Ngai, H. Y.
    Au, W. H.
    BJU INTERNATIONAL, 2019, 123 : 16 - 17
  • [5] Aortic 3D Deformation Reconstruction using 2D X-ray Fluoroscopy and 3D Pre-operative Data for Endovascular Interventions
    Zhang, Yanhao
    Zhao, Liang
    Huang, Shoudong
    2020 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2020, : 2393 - 2399
  • [6] The Accuracy of 3D Rectal Ultrasound for Pre-Operative Rectal Cancer Staging
    Arya, Aman V.
    Romagnoli, Cesare
    Man, Lu
    Hussain, Nadeem
    Fenster, Aaron
    Yan, Brian
    GASTROENTEROLOGY, 2012, 142 (05) : S342 - S342
  • [7] Comparison of the Accuracy of 2D and 3D Templating for Revision Total Hip Replacement
    Winter, Philipp
    Fritsch, Ekkehard
    Konig, Jochem
    Wolf, Milan
    Landgraeber, Stefan
    Orth, Patrick
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (03):
  • [8] 2D/3D Registration of Pre-Operative MRI Models with a Single Radiographic Image: Feasibility Study
    Chevrefils, C.
    Duong, L.
    Cheriet, F.
    Parent, S.
    Aubin, C. E.
    RESEARCH INTO SPINAL DEFORMITIES 7, 2010, 158 : 216 - 216
  • [9] IMPROVING PRE-OPERATIVE EVALUATION AND SURGICAL PLANNING OF SPINE DEFORMITY SURGERIES USING 3D PRINTING
    Pfeiffer, Ferris M.
    PROCEEDINGS OF THE 4TH FRONTIERS IN BIOMEDICAL DEVICES CONFERENCE AND EXPOSITION - 2009, 2009, : 77 - 78
  • [10] Advantages and disadvantages of 3D printing for pre-operative planning of revision hip surgery
    Tserovski, Stefan
    Georgieva, Simona
    Simeonov, Radoil
    Bigdeli, Amir
    Roettinger, Heinz
    Kinov, Plamen
    JOURNAL OF SURGICAL CASE REPORTS, 2019, (07):