Kinetics of laser induced changes of characteristic optical properties in Lithosil® with 193nm excimer laser exposure

被引:10
|
作者
Natura, U [1 ]
Martin, R [1 ]
von der Goenna, G [1 ]
Kahlke, M [1 ]
Fasold, G [1 ]
机构
[1] SCHOTT Lithotec AG, D-07745 Jena, Germany
来源
Optical Microlithography XVIII, Pts 1-3 | 2005年 / 5754卷
关键词
defect generation; fused silica; rapid damage process; pre-irradiation effect;
D O I
10.1117/12.599319
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Fused silica is used as lens material in DUV microlithography systems. The kinetics of slow radiation induced defect generation in Lithosil (R) including absorption, hydrogen consumption and changes of the refractive index is described in detail and in very good agreement with measured data in previous papers. In addition to these effects after long time irradiation fused silica is characterized by rapid damage processes (RDP) after short time irradiation. A model describing the absorption of RDP in dependence on energy density, repetition rate and time is described in this paper, the sensitivity of RDP on pre-irradiation and illumination conditions is discussed. Furthermore a method to reduce energy dependent absorption of RDP is mentioned.
引用
收藏
页码:1312 / 1319
页数:8
相关论文
共 50 条
  • [11] DAMAGE MECHANISMS FOR 193NM EXCIMER-LASER CORNEAL ABLATION
    MANSTEIN, D
    FORSTER, W
    SCHURENBERG, M
    HILLENKAMP, F
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 2012 - 2012
  • [12] Excimer laser induced defect generation in lithosil
    Natura, U
    Sohr, O
    Letz, M
    Martin, R
    Kahlke, M
    Fasold, G
    OPTICAL MICROLITHOGRAPHY XVII, PTS 1-3, 2004, 5377 : 1708 - 1714
  • [13] PHOTOACOUSTIC INJURY AND BONE HEALING FOLLOWING 193NM EXCIMER LASER ABLATION
    LUSTMANN, J
    ULMANSKY, M
    FUXBRUNNER, A
    LEWIS, A
    LASERS IN SURGERY AND MEDICINE, 1992, 12 (04) : 390 - 396
  • [14] High-resolution microlithography using a 193nm excimer laser source
    Rizvi, NH
    Ashworth, D
    Cashmore, JS
    Gower, MC
    XI INTERNATIONAL SYMPOSIUM ON GAS FLOW AND CHEMICAL LASERS AND HIGH-POWER LASER CONFERENCE, 1997, 3092 : 471 - 476
  • [15] VITREORETINAL ABLATION IN FLUID MEDIA WITH 193NM EXCIMER-LASER BEAM
    ZAUBERMAN, H
    HEMO, I
    PALANKER, D
    TUROVETS, I
    LEWIS, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1261 - 1261
  • [16] Microfiber Fabry-Perot Sensors Inscribed by 193nm Excimer Laser
    Li, Jie
    Shen, Xiang
    Sun, Li-Peng
    Guan, Bai-Ou
    2012 PHOTONICS GLOBAL CONFERENCE (PGC), 2012,
  • [17] 193nm excimer laser inscribed Bragg gratings in microfibers for refractive index sensing
    Ran, Yang
    Tan, Yan-Nan
    Sun, Li-Peng
    Gao, Shuai
    Li, Jie
    Jin, Long
    Guan, Bai-Ou
    OPTICS EXPRESS, 2011, 19 (19): : 18577 - 18583
  • [18] UV LASER PHOTOCHEMISTRY OF ACETYLENE AT 193NM
    IRION, MP
    KOMPA, KL
    APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1982, 27 (04): : 183 - 186
  • [19] Update on laser vision correction using wavefront analysis with the customcornea system and ladarvision 193nm excimer laser
    Maguen, E
    Salz, JJ
    McDonald, M
    Pettit, GH
    Papaioannou, T
    Grundfest, WS
    OPHTHALMIC TECHNOLOGIES XII, 2002, 4611 : 143 - 148
  • [20] Glass densification under 193nm laser exposure: Experiment and theory.
    Allan, DC
    Smith, C
    Borrelli, NF
    Seward, TP
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 23 - COMP