The mechanical behavior of a new designed hip spacer

被引:0
|
作者
Thielen, T. [1 ]
Maas, S. [1 ]
Zuerbes, A. [1 ]
Waldmann, D. [1 ]
Anagnostakos, K. [2 ]
Kelm, J. [2 ]
机构
[1] Univ Luxembourg, Res Unit Engn Sci, 6 Rue Richard Coudenhove Kalergi, L-1359 Luxembourg, Luxembourg
[2] Univ Hosp, Dept Orthoped Surg, Homburg, Germany
关键词
Spacer; Fracture; PMMA; Hip joint; Infection; BONE-CEMENT; 2-STAGE REVISION;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Within this project a new hip spacer made of antibiotic impregnated bone cement used in two-stage treatment of infected hip joints was developed. As the material strength of bone cement is limited, fractures occurred in the past and led to important complications, so that a reinforcement of titanium was designed. Different shapes for this reinforcement were investigated and tested. The loading procedure was close to the ISO 7206-4, though small adaptation was made. An inserted rod of titanium grade II increased the collapse load up to 1000 - 1300 N, but considering a maximum expected force of about three times body weight, a "full-stem" reinforced spacer was created with titanium endoskeleton and a coating of minimum 2 mm PMMA. A finite element model was used to design this device so that finally a mobile and functional joint through the treatment course can be guaranteed. This new spacer is moulded during surgery and thus may be adapted optimal to the patients infect and his individual needs.
引用
收藏
页码:21 / 24
页数:4
相关论文
共 50 条
  • [31] Determination of Mechanical Behavior of New Biocomposites
    Busuioceanu, Ioana Iuliana
    Enachescu, Georgiana-Luminita
    Baciu, Florin
    Dinu, Gabriela
    Stefanescu, Mariana Florentina
    7TH INTERNATIONAL CONFERENCE ON STRUCTURAL ANALYSIS OF ADVANCED MATERIALS (ICSAAM 2017), 2018, 1932
  • [32] The mechanical behavior of 3D bi-axial spacer weft knitting fabrics
    Zhang Ming-xing
    Hu Hong
    PROCEEDINGS OF 2009 INTERNATIONAL TEXTILE SCIENCE AND TECHNOLOGY FORUM, 2010, : 285 - 291
  • [33] Novel weft-knitted spacer structure with silicone tube inlay for enhancing mechanical behavior
    Yu, Annie
    Sukigara, Sachiko
    Yick, Kit-Lun
    Li, Pui-Ling
    MECHANICS OF ADVANCED MATERIALS AND STRUCTURES, 2022, 29 (14) : 2053 - 2064
  • [34] Evaluation of the mechanical behavior of porous pieces of titanium, obtained by powder metallurgy and superactivated carbon as spacer
    Melendez, Angel
    Cabello-Sequera, Sandra
    INGENIERIA UC, 2022, 29 (01): : 87 - 95
  • [35] Numerical Simulation of a New Designed Mechanical Seals with Spiral Groove Structures
    He, Tao
    Zhang, Qiangqiang
    Yan, Ying
    Dong, Jintong
    Zhou, Ping
    LUBRICANTS, 2023, 11 (02)
  • [36] The modified spacer for first stage revision hip arthroplasty
    Blake, S. M.
    Ashworth, M.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2016, 98 (01) : 70 - 71
  • [37] Digitally designed, personalized bone cement spacer for staged TMJ and mandibular reconstruction-Introduction of a new technique
    Teschke, Marcus
    Christensen, Andy
    Far, Frederick
    Reich, Rudolf H.
    Naujokat, Hendrik
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2021, 49 (10) : 935 - 942
  • [38] Spacer endoprosthesis for the treatment of infected total hip arthroplasty
    Durbhakula, SM
    Czajka, J
    Fuchs, MD
    Uhl, RL
    JOURNAL OF ARTHROPLASTY, 2004, 19 (06): : 760 - 767
  • [39] Optimisation of a Reinforced Cement Spacer in Total Hip Arthroplasty
    Salah, H.
    Bouziane, M. M.
    Fekih, S. M.
    Bouiadjra, B. Bachir
    Benbarek, S.
    JOURNAL OF BIOMIMETICS BIOMATERIALS AND BIOMEDICAL ENGINEERING, 2018, 35 : 35 - 49
  • [40] A new biarticular cement spacer technique for infected total hip and knee arthroplasty with massive bone loss
    Sanz-Ruiz, Pablo
    Antonio Matas-Diez, Jose
    Villanueva-Martinez, Manuel
    Carbo-Laso, Esther
    Isabel Lopez-Torres, Irene
    Vaquero-Martin, Javier