The mechanical behavior of a new designed hip spacer

被引:0
|
作者
Thielen, T. [1 ]
Maas, S. [1 ]
Zuerbes, A. [1 ]
Waldmann, D. [1 ]
Anagnostakos, K. [2 ]
Kelm, J. [2 ]
机构
[1] Univ Luxembourg, Res Unit Engn Sci, 6 Rue Richard Coudenhove Kalergi, L-1359 Luxembourg, Luxembourg
[2] Univ Hosp, Dept Orthoped Surg, Homburg, Germany
关键词
Spacer; Fracture; PMMA; Hip joint; Infection; BONE-CEMENT; 2-STAGE REVISION;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Within this project a new hip spacer made of antibiotic impregnated bone cement used in two-stage treatment of infected hip joints was developed. As the material strength of bone cement is limited, fractures occurred in the past and led to important complications, so that a reinforcement of titanium was designed. Different shapes for this reinforcement were investigated and tested. The loading procedure was close to the ISO 7206-4, though small adaptation was made. An inserted rod of titanium grade II increased the collapse load up to 1000 - 1300 N, but considering a maximum expected force of about three times body weight, a "full-stem" reinforced spacer was created with titanium endoskeleton and a coating of minimum 2 mm PMMA. A finite element model was used to design this device so that finally a mobile and functional joint through the treatment course can be guaranteed. This new spacer is moulded during surgery and thus may be adapted optimal to the patients infect and his individual needs.
引用
收藏
页码:21 / 24
页数:4
相关论文
共 50 条
  • [21] Finite element analysis of the mechanical behavior of a nuclear fuel assembly spacer grid
    Yoo, Youngik
    Kim, Kyounghong
    Eom, Kyongbo
    Lee, Seongki
    NUCLEAR ENGINEERING AND DESIGN, 2019, 352
  • [22] Prolonged use of spacer in hip infection. New treatment modality in two stages
    Rey, Rogelio Freddy
    Teske, Viviana
    REVISTA MEDICA DEL URUGUAY, 2012, 28 (01): : 13 - 20
  • [23] Effects of dynamic loading on the mechanical behavior of total hip prosthesis
    Charef, Djilali
    Serier, Boualem
    Journal of Biomechanical Science and Engineering, 2015, 10 (04):
  • [24] An intramedullary cement spacer in total hip arthroplasty
    Deshmukh, RG
    Thevarajan, K
    Kok, CS
    Sivapathasundaram, N
    George, SVN
    JOURNAL OF ARTHROPLASTY, 1998, 13 (02): : 197 - 199
  • [25] Synthesis of new hybrid materials designed for iron selective electrodes based on selective amino spacer organizations
    Rouge, Pascal
    Becuwe, Mathieu
    Dassonville-Klimpt, Alexandra
    Jonet, Alexia
    Benazza, Mohammed
    Guery, Claude
    Baudrin, Emmanuel
    Sonnet, Pascal
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 240
  • [26] Mechanical behavior of FSW joint welded by a novel designed stationary shoulder tool
    Sinhmar, Sunil
    Dwivedi, Dheerendra Kumar
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2020, 277
  • [27] Biomechanical Analysis of Fatigue Behavior of a Fully Composite-based Designed Hip Resurfacing Prosthesis
    Chergui, K.
    Ameddah, H.
    Mazouz, H.
    JOURNAL OF THE SERBIAN SOCIETY FOR COMPUTATIONAL MECHANICS, 2018, 12 (02) : 80 - 94
  • [28] Custom made articulating hip spacer for staged revision in Birmingham hip resurfacing
    David, B.
    Chandrasekar, S.
    Aldam, C. H.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2014, 96 (04) : 314 - 314
  • [29] Numerical Modeling of the Mechanical Behavior of Hip Resurfacing Endoprosthesis and Healthy Bone
    Eremina, G. M.
    Smolin, A. Yu.
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS WITH HIERARCHICAL STRUCTURE FOR NEW TECHNOLOGIES AND RELIABLE STRUCTURES 2019, 2019, 2167
  • [30] A NEW CONCEPT OF THE MECHANICAL BEHAVIOR OF FIBERS
    BURTE, H
    HALSEY, G
    DILLON, JH
    TEXTILE RESEARCH JOURNAL, 1948, 18 (08) : 449 - 469