The mechanical behavior of a new designed hip spacer

被引:0
|
作者
Thielen, T. [1 ]
Maas, S. [1 ]
Zuerbes, A. [1 ]
Waldmann, D. [1 ]
Anagnostakos, K. [2 ]
Kelm, J. [2 ]
机构
[1] Univ Luxembourg, Res Unit Engn Sci, 6 Rue Richard Coudenhove Kalergi, L-1359 Luxembourg, Luxembourg
[2] Univ Hosp, Dept Orthoped Surg, Homburg, Germany
关键词
Spacer; Fracture; PMMA; Hip joint; Infection; BONE-CEMENT; 2-STAGE REVISION;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Within this project a new hip spacer made of antibiotic impregnated bone cement used in two-stage treatment of infected hip joints was developed. As the material strength of bone cement is limited, fractures occurred in the past and led to important complications, so that a reinforcement of titanium was designed. Different shapes for this reinforcement were investigated and tested. The loading procedure was close to the ISO 7206-4, though small adaptation was made. An inserted rod of titanium grade II increased the collapse load up to 1000 - 1300 N, but considering a maximum expected force of about three times body weight, a "full-stem" reinforced spacer was created with titanium endoskeleton and a coating of minimum 2 mm PMMA. A finite element model was used to design this device so that finally a mobile and functional joint through the treatment course can be guaranteed. This new spacer is moulded during surgery and thus may be adapted optimal to the patients infect and his individual needs.
引用
收藏
页码:21 / 24
页数:4
相关论文
共 50 条
  • [1] Finite element analysis of the mechanical strength of a new hip Spacer
    Ge, Hao
    Yan, Hongsong
    Liu, Xianwang
    Huang, Yiwei
    Zeng, Jianchun
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [2] Finite element analysis of the mechanical strength of a new hip Spacer
    Hao Ge
    Hongsong Yan
    Xianwang Liu
    Yiwei Huang
    Jianchun Zeng
    BMC Musculoskeletal Disorders, 24
  • [3] A study on the compression behavior of spacer fabrics designed for concrete applications
    Armakan, Diren M.
    Roye, Andreas
    FIBERS AND POLYMERS, 2009, 10 (01) : 116 - 123
  • [4] A study on the compression behavior of spacer fabrics designed for concrete applications
    Diren M. Armakan
    Andreas Roye
    Fibers and Polymers, 2009, 10 : 116 - 123
  • [5] Mechanical complications and reconstruction strategies at the site of hip spacer implantation
    Anagnostakos, Konstantinos
    Jung, Jochen
    Schmid, Nora Verena
    Schmitt, Eduard
    Kelm, Jens
    INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2009, 6 (05): : 274 - 279
  • [6] Investigation of mechanical behavior on the cement hip spacer geometry under finite element method and compression load test
    Warinsiriruk, Eakkachai
    Thongchuea, Nutchanat
    Pengrung, Nachapan
    Jarungvittayakon, Chavarat
    Sa-Ngasoongsong, Paphon
    Chulsomlee, Kulapat
    JOURNAL OF ORTHOPAEDICS, 2024, 47 : 115 - 121
  • [7] Preventing mechanical complications of hip spacer implantation : technical tips and pearls
    Barreira, Pedro
    Leite, Pedro
    Neves, Pedro
    Soares, Daniel
    Sousa, Ricardo
    ACTA ORTHOPAEDICA BELGICA, 2015, 81 (02): : 344 - 348
  • [8] STUDY OF THE PERFORMANCES OF A NEW SPACER IN MECHANICAL VENTILATION
    Boukhettala, Nabile
    Poree, Thierry
    Diot, Patrice
    Vecellio, Laurent
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2013, 26 (02) : A42 - A42
  • [9] Investigation of a Testing Method for Compression Behavior of Spacer Fabrics Designed for Concrete Applications
    Mecit, Diren
    Roye, Andreas
    TEXTILE RESEARCH JOURNAL, 2009, 79 (10) : 867 - 875
  • [10] Study of the performances of a new spacer in adult mechanical ventilation
    Boukhettala, Nabile
    Poree, Thierry
    Diot, Patrice
    Vecellio, Laurent
    EUROPEAN RESPIRATORY JOURNAL, 2013, 42