Real-time Uncertainty Visualization for B-Mode Ultrasound

被引:0
|
作者
Berge, Christian Schulte Zu
Declara, Denis
Hennersperger, Christoph
Baust, Maximilian
Navab, Nassir
机构
关键词
Ultrasound; Uncertainty Visualization; Confidence Maps; Real-time; CONFIDENCE;
D O I
暂无
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
B-mode ultrasound is a very well established imaging modality and is widely used in many of today's clinical routines. However, acquiring good images and interpreting them correctly is a challenging task due to the complex ultrasound image formation process depending on a large number of parameters. To facilitate ultrasound acquisitions, we introduce a novel framework for real-time uncertainty visualization in B-mode images. We compute real-time perpixel ultrasound Confidence Maps, which we fuse with the original ultrasound image in order to provide the user with an interactive feedback on the quality and credibility of the image. In addition to a standard color overlay mode, primarily intended for educational purposes, we propose two perceptional visualization schemes to be used in clinical practice. Our mapping of uncertainty to chroma uses the perceptionally uniform L*a*b* color space to ensure that the perceived brightness of B-mode ultrasound remains the same. The alternative mapping of uncertainty to fuzziness keeps the B-mode image in its original grayscale domain and locally blurs or sharpens the image based on the uncertainty distribution. An elaborate evaluation of our system and user studies on both medical students and expert sonographers demonstrate the usefulness of our proposed technique. In particular for ultrasound novices, such as medical students, our technique yields powerful visual cues to evaluate the image quality and thereby learn the ultrasound image formation process. Furthermore, seeing the distribution of uncertainty adjust to the transducer positioning in real-time, provides also expert clinicians with a strong visual feedback on their actions. This helps them to optimize the acoustic window and can improve the general clinical value of ultrasound.
引用
收藏
页码:33 / 40
页数:8
相关论文
共 50 条
  • [41] Diagnosis of Pseudopregnancy in a Beetal Goat Using Real-Time B-Mode Ultrasonography
    Khan, Muhammad Irfan-ur-Rehman
    Channa, Aijaz Ali
    Sattar, Abdul
    PAKISTAN VETERINARY JOURNAL, 2015, 35 (04) : 537 - 539
  • [42] MEASUREMENT VARIABILITY OF CAROTID ATHEROSCLEROSIS - REAL-TIME (B-MODE) ULTRASONOGRAPHY AND ANGIOGRAPHY
    OLEARY, DH
    BRYAN, FA
    GOODISON, MW
    RIFKIN, MD
    GRAMIAK, R
    BALL, M
    BOND, MG
    DUNN, RA
    GOLDBERG, BB
    TOOLE, JF
    WHEELER, HG
    GUSTAFSON, NF
    EKHOLM, S
    RAINES, JK
    STROKE, 1987, 18 (06) : 1011 - 1017
  • [43] DETECTION OF DEEP-VEIN THROMBOSIS BY REAL-TIME B-MODE ULTRASONOGRAPHY
    LENSING, AWA
    PRANDONI, P
    BRANDJES, D
    HUISMAN, PM
    VIGO, M
    TOMASELLA, G
    KREKT, J
    TENCATE, JW
    HUISMAN, MV
    BULLER, HR
    NEW ENGLAND JOURNAL OF MEDICINE, 1989, 320 (06): : 342 - 345
  • [44] B-mode, real-time ultrasound for estimating carcass measures in live sheep: Accuracy of ultrasound measures and their relationships with carcass yield and value
    Leeds, T. D.
    Mousel, M. R.
    Notter, D. R.
    Zerby, H. N.
    Moffet, C. A.
    Lewis, G. S.
    JOURNAL OF ANIMAL SCIENCE, 2008, 86 (11) : 3203 - 3214
  • [45] VALUE OF REAL-TIME B-MODE ULTRASOUND IMAGING IN THE DIAGNOSIS OF DEEP-VEIN THROMBOSIS OF THE LOWER-LIMBS
    ELIAS, A
    LECORFF, G
    BOUVIER, JL
    BENICHOU, M
    SERRADIMIGNI, A
    INTERNATIONAL ANGIOLOGY, 1987, 6 (02) : 175 - 182
  • [46] Real-Time 3D Curved Needle Segmentation Using Combined B-Mode and Power Doppler Ultrasound
    Greer, Joseph D.
    Adebar, Troy K.
    Hwang, Gloria L.
    Okamura, Allison M.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2014, PT II, 2014, 8674 : 381 - 388
  • [47] LIVER FIBROSIS ASSESSMENT USING TRANSIENT ELASTOGRAPHY GUIDED WITH REAL-TIME B-MODE ULTRASOUND IMAGING: A FEASIBILITY STUDY
    Mak, Tak-Man
    Huang, Yan-Ping
    Zheng, Yong-Ping
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (06): : 956 - 966
  • [48] COMPARISON OF REAL-TIME B-MODE ULTRASONOGRAPHY AND DOPPLER ULTRASOUND WITH CONTRAST VENOGRAPHY IN THE DIAGNOSIS OF VENOUS THROMBOSIS IN SYMPTOMATIC OUTPATIENTS
    COGO, A
    LENSING, AWA
    PRANDONI, P
    BULLER, HR
    GIROLAMI, A
    TENCATE, JW
    THROMBOSIS AND HAEMOSTASIS, 1993, 70 (03) : 404 - 407
  • [49] B-Mode Ultrasound Imaging, Doppler Imaging, and Real-Time Elastography in Cutaneous Malignant Melanoma and Lymph Node Metastases
    Uematsu, Takayoshi
    Kasami, Masako
    Kiyohara, Yoshio
    HEALTHCARE, 2013, 1 (01): : 84 - 95
  • [50] Real-time B-mode Cardiac Time-harmonic Elastography for the Detection of Diastolic Dysfunction
    Hattasch, Robert
    Tzschaetzsch, Heiko
    Knebel, Fabian
    Elgeti, Thomas
    Schultz, Michael
    Klaua, Robert
    Braun, Juergen
    Sack, Ingolf
    CIRCULATION, 2014, 130