LIVER FIBROSIS ASSESSMENT USING TRANSIENT ELASTOGRAPHY GUIDED WITH REAL-TIME B-MODE ULTRASOUND IMAGING: A FEASIBILITY STUDY

被引:16
|
作者
Mak, Tak-Man [1 ]
Huang, Yan-Ping [1 ]
Zheng, Yong-Ping [1 ]
机构
[1] Hong Kong Polytech Univ, Fac Engn, Interdisciplinary Div Biomed Engn, Kowloon, Hong Kong, Peoples R China
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2013年 / 39卷 / 06期
关键词
Ultrasound; Transient elastography; Elasticity measurement; Liver fibrosis; Soft tissue; Indentation; MAGNETIC-RESONANCE ELASTOGRAPHY; NONINVASIVE ASSESSMENT; BIOCHEMICAL MARKERS; SOFT-TISSUES; STIFFNESS; BIOPSY; CIRRHOSIS; REPRODUCIBILITY; ELASTICITY; MORTALITY;
D O I
10.1016/j.ultrasmedbio.2013.01.009
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Liver fibrosis is a kind of chronic damage of the liver and can lead to cirrhosis, one of the top 10 causes of death in the Western world. However, there is still a lack of noninvasive methods for diagnosing liver fibrosis. Fibroscan (Echosens, Paris, France), a device based on A-mode transient elastography, has shown promising results. In this study, a transient elastography system with real-time B-mode imaging for non-invasive liver fibrosis assessment, named Liverscan, was developed; its performance was tested and compared with that of the Fibroscan. A specific measurement probe was designed and fabricated with a B-mode ultrasound transducer fixed along the axis of a mechanical vibrator. It was integrated with the Liverscan to measure liver stiffness based on the shear wave propagation in liver tissues. The system was validated by mechanical indentation test using custom-made agar-gelatin phantoms with different stiffness. To further test its feasibility, in vivo measurements were conducted in 67 volunteers (age, 34 +/- 3 years; body mass index, 21.3 +/- 2.8 kg/m(2); Mean +/- SD., 34 male and 33 female), including 20 patients with various liver diseases, and 28 (19 male and 9 female) being tested by both Liverscan and Fibroscan. A significant linear correlation between the stiffness measured by the mechanical indentation test and that by the Liverscan (r = 0.973; p < 0.001) was obtained. The in vivo liver stiffness measured by Liverscan was also correlated with that by Fibroscan significantly (r = 0.886; p < 0.001). There was a significant difference in liver stiffness between the 20 patients and the other healthy subjects (14.1 +/- 3.4 kPa vs. 10.5 +/- 2.1 kPa; p = 0.001). The intra-and inter-observer tests indicated that the measurements were repeatable with intra-class correlation coefficients being 0.987 (p < 0.001) and 0.988 (p < 0.001), respectively. This study demonstrated that Liverscan with a specifically designed probe was able to measure and differentiate liver of different stiffness using the established measurement protocol under the guidance of real-time B-mode ultrasound imaging. (E-mail: ypzheng@ieee.org) (C) 2013 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:956 / 966
页数:11
相关论文
共 50 条
  • [1] Liver Fibrosis Assessment Using Transient Elastography Guided with Real-Time B-Mode Ultrasound Imaging
    Zheng, Yong-Ping
    Mak, Tak-Man
    Huang, Zheng-Ming
    Cheung, Chung-Wai James
    Zhou, Yong-Jin
    He, Jun-Feng
    6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3, 2010, 31 : 1036 - 1039
  • [2] Palm-Sized Wireless Transient Elastography System with Real-Time B-Mode Ultrasound Imaging Guidance: Toward Point-of-Care Liver Fibrosis Assessment
    Huang, Zi-Hao
    Wang, Li-Ke
    Cai, Shang-Yu
    Chen, Hao-Xin
    Zhou, Yongjin
    Cheng, Lok-Kan
    Lin, Yi-Wei
    Zheng, Ming-Hua
    Zheng, Yong-Ping
    DIAGNOSTICS, 2024, 14 (02)
  • [3] PERFORMANCE OF REAL-TIME ELASTOGRAPHY AND TRANSIENT ELASTOGRAPHY IN THE ASSESSMENT OF LIVER FIBROSIS IN CHRONIC HEPATITIS
    Ferraioli, Giovanna
    Tinelli, Carmine
    Dal Bello, Barbara
    Calderon, Willy
    Lissandrin, Raffaella
    Filice, Carlo
    HEPATOLOGY, 2011, 54 : 816A - 816A
  • [4] Real-time elastography in the assessment of liver fibrosis
    Ferraioli, Giovanna
    Gulizia, Rosario
    Filice, Carlo
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (03) : W170 - W170
  • [5] REAL-TIME B-MODE VENOUS ULTRASOUND
    SULLIVAN, ED
    PETER, DJ
    CRANLEY, JJ
    JOURNAL OF VASCULAR SURGERY, 1984, 1 (03) : 465 - 471
  • [6] B-Mode Ultrasound Imaging, Doppler Imaging, and Real-Time Elastography in Cutaneous Malignant Melanoma and Lymph Node Metastases
    Uematsu, Takayoshi
    Kasami, Masako
    Kiyohara, Yoshio
    HEALTHCARE, 2013, 1 (01): : 84 - 95
  • [7] Real-time ultrasound elastography: Does it improve B-mode ultrasound characterization of solid breast lesions?
    Shaaban, Marwa A.
    Aly, Abo El-Ata K.
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2012, 43 (02): : 301 - 309
  • [8] Correlates of mammographic density in B-mode ultrasound and real time elastography
    Jud, Sebastian Michael
    Haeberle, Lothar
    Fasching, Peter A.
    Heusinger, Katharina
    Hack, Carolin
    Faschingbauer, Florian
    Uder, Michael
    Wittenberg, Thomas
    Wagner, Florian
    Meier-Meitinger, Martina
    Schulz-Wendtland, Ruediger
    Beckmann, Matthias W.
    Adamietz, Boris R.
    EUROPEAN JOURNAL OF CANCER PREVENTION, 2012, 21 (04) : 343 - 349
  • [9] Open questions in the assessment of liver fibrosis using real-time elastography
    Gulizia, Rosario
    Ferraioli, Giovanna
    Filice, Carlo
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (06) : W370 - W371
  • [10] Reply to real-time elastography in the assessment of liver fibrosis
    Friedrich-Rust, Mireen
    Herrmann, Eva
    Zeuzem, Stefan
    Sarrazin, Christoph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (02) : W164 - W164