Simultaneous Determination of Copper(II), Lead(II) and Zinc(II) at Bismuth Film Electrode by Multivariate Calibration

被引:31
|
作者
Alves, Georgina M. S. [1 ]
Magalhaes, Julia M. C. S. [1 ]
Soares, Helena M. V. M. [1 ]
机构
[1] Univ Porto, Fac Engn, Dept Engn Quim, REQUIMTE, P-4200465 Oporto, Portugal
关键词
Bismuth film electrode (BiFE); Partial least squares (PLS); Square wave anodic stripping voltammetry (SWASV); Trace metals; ANODIC-STRIPPING VOLTAMMETRY; PARTIAL LEAST-SQUARES; TRACE-METALS; REGRESSION CALIBRATION; SOFT CALIBRATION; HEAVY-METALS; SPECIATION; CADMIUM; INTERFERENCE; CHEMOMETRICS;
D O I
10.1002/elan.201000696
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, simultaneous determination of Cu(II), Pb(II) and Zn(II) ions at low concentration levels (ppb) by square wave anodic stripping voltammetry on a Bi(III) film electrode plated in situ at a glassy carbon electrode (GCE) is described. A chemometric approach was used to overcome the overlapping peaks of Cu(II) and Bi(III), the competition of the electrodeposited Cu and Bi for the surface of the GCE and the formation of Cu-Zn intermetallic compounds. The construction of the multivariate calibration models, based on partial least squares regression, allowed the simultaneous determination of Cu (in the concentration range 8.0 to 20.1 ppb), Pb (2.0 to 30.0 ppb) and Zn (29.7 to 90.4 ppb) with most of the prediction errors obtained in the external validation set for the three models lower than 16, 11 and 26%, respectively. Finally, this method was used for the determination of these trace metal ions in surface river water samples with satisfactory results [errors below 10, 5 and 32% for Cu(II), Pb(II) and Zn(II), respectively].
引用
收藏
页码:1410 / 1417
页数:8
相关论文
共 50 条
  • [31] Simultaneous determination of copper, lead and zinc in alloy by complexometric titration coupled with multivariate calibration
    School of Chemistry and Chemical Engineering, University of South China, Hengyang 421001, China
    Yejin Fenxi, 2008, 9 (54-57):
  • [32] A screen-printed carbon electrode modified with a bismuth film and gold nanoparticles for simultaneous stripping voltammetric determination of Zn(II), Pb(II) and Cu(II)
    Lu, Zhiwei
    Zhang, Junjun
    Dai, Wanlin
    Lin, Xueni
    Ye, Jiaping
    Ye, Jianshan
    MICROCHIMICA ACTA, 2017, 184 (12) : 4731 - 4740
  • [33] A screen-printed carbon electrode modified with a bismuth film and gold nanoparticles for simultaneous stripping voltammetric determination of Zn(II), Pb(II) and Cu(II)
    Zhiwei Lu
    Junjun Zhang
    Wanlin Dai
    Xueni Lin
    Jiaping Ye
    Jianshan Ye
    Microchimica Acta, 2017, 184 : 4731 - 4740
  • [34] Fast simultaneous adsorptive stripping voltammetric determination of ni(II) and co(II) at lead film electrode plated on gold substrate
    Tyszczuk, Katarzyna
    Korolczuk, Mieczyslaw
    ELECTROANALYSIS, 2007, 19 (14) : 1539 - 1542
  • [35] Electroanalytical Determination of Cadmium(II) and Lead(II) Using an in-situ Bismuth Film Modified Edge Plane Pyrolytic Graphite Electrode
    Roohollah Torabi Kachoosangi
    Craig E. Banks
    Xiaobo Ji
    Richard G. Compton
    Analytical Sciences, 2007, 23 : 283 - 289
  • [36] Simultaneous determination of copper(II) and zinc(II) via simple acid-base titrimetry using glass pH electrode
    Cansu Ergun, Emine Gul
    Kenar, Adnan
    TURKISH JOURNAL OF CHEMISTRY, 2018, 42 (02) : 257 - 263
  • [37] Electroanalytical determination of cadmium(II) and lead(II) using an in-situ bismuth film modified edge plane pyrolytic graphite electrode
    Kachoosangi, Roohollah Torabi
    Banks, Craig E.
    Ji, Xiaobo
    Compton, Richard G.
    ANALYTICAL SCIENCES, 2007, 23 (03) : 283 - 289
  • [38] Bismuth as an Electrode Material in the Simultaneous Determination of Pb (II) and Cd (II) in Poplar (Populus) Leaves by SWASV
    Silva, N. A. F.
    Leitao, R. A. E.
    Matos, M. J.
    PORTUGALIAE ELECTROCHIMICA ACTA, 2006, 24 (02) : 283 - 293
  • [39] Determination of lead(II), copper(II), zinc(II), cobalt(II), cadmium(II), iron(III), mercury(II) using sequential injection extractions
    van Staden, JF
    Taljaard, RE
    TALANTA, 2004, 64 (05) : 1203 - 1212
  • [40] Simultaneous voltammetric determination of cadmium(II), lead(II), mercury(II), zinc(II), and copper(II) using a glassy carbon electrode modified with magnetite (Fe3O4) nanoparticles and fluorinated multiwalled carbon nanotubes
    Wu, Wenqin
    Jia, Mingming
    Wang, Zhongzheng
    Zhang, Wen
    Zhang, Qi
    Liu, Guozhen
    Zhang, Zhaowei
    Li, Peiwu
    MICROCHIMICA ACTA, 2019, 186 (02)