Simultaneous Determination of Copper(II), Lead(II) and Zinc(II) at Bismuth Film Electrode by Multivariate Calibration

被引:31
|
作者
Alves, Georgina M. S. [1 ]
Magalhaes, Julia M. C. S. [1 ]
Soares, Helena M. V. M. [1 ]
机构
[1] Univ Porto, Fac Engn, Dept Engn Quim, REQUIMTE, P-4200465 Oporto, Portugal
关键词
Bismuth film electrode (BiFE); Partial least squares (PLS); Square wave anodic stripping voltammetry (SWASV); Trace metals; ANODIC-STRIPPING VOLTAMMETRY; PARTIAL LEAST-SQUARES; TRACE-METALS; REGRESSION CALIBRATION; SOFT CALIBRATION; HEAVY-METALS; SPECIATION; CADMIUM; INTERFERENCE; CHEMOMETRICS;
D O I
10.1002/elan.201000696
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, simultaneous determination of Cu(II), Pb(II) and Zn(II) ions at low concentration levels (ppb) by square wave anodic stripping voltammetry on a Bi(III) film electrode plated in situ at a glassy carbon electrode (GCE) is described. A chemometric approach was used to overcome the overlapping peaks of Cu(II) and Bi(III), the competition of the electrodeposited Cu and Bi for the surface of the GCE and the formation of Cu-Zn intermetallic compounds. The construction of the multivariate calibration models, based on partial least squares regression, allowed the simultaneous determination of Cu (in the concentration range 8.0 to 20.1 ppb), Pb (2.0 to 30.0 ppb) and Zn (29.7 to 90.4 ppb) with most of the prediction errors obtained in the external validation set for the three models lower than 16, 11 and 26%, respectively. Finally, this method was used for the determination of these trace metal ions in surface river water samples with satisfactory results [errors below 10, 5 and 32% for Cu(II), Pb(II) and Zn(II), respectively].
引用
收藏
页码:1410 / 1417
页数:8
相关论文
共 50 条
  • [21] Determination of Lead(II) Using Screen-Printed Bismuth-Antimony Film Electrode
    Chen, Chen
    Niu, Xiangheng
    Chai, Yan
    Zhao, Hongli
    Lan, Minbo
    Zhu, Yonggang
    Wei, Gang
    ELECTROANALYSIS, 2013, 25 (06) : 1446 - 1452
  • [22] Simultaneous determination of cadmium(II), lead(II) and copper(II) by using a screen-printed electrode modified with mercury nano-droplets
    Song, Wei
    Zhang, Lei
    Shi, Lei
    Li, Da-Wei
    Li, Yang
    Long, Yi-Tao
    MICROCHIMICA ACTA, 2010, 169 (3-4) : 321 - 326
  • [23] Simultaneous determination of cadmium(II), lead(II) and copper(II) by using a screen-printed electrode modified with mercury nano-droplets
    Wei Song
    Lei Zhang
    Lei Shi
    Da-Wei Li
    Yang Li
    Yi-Tao Long
    Microchimica Acta, 2010, 169 : 321 - 326
  • [24] Coprecipitation for the Determination of Copper(II), Zinc(II), and Lead(II) in Seawater by Flame Atomic Absorption Spectrometry
    Urucu, Oya Aydin
    Aydin, Adnan
    ANALYTICAL LETTERS, 2015, 48 (11) : 1767 - 1776
  • [25] Metallated porphyrins containing lead(II), copper(II) or zinc(II)
    Plater, MJ
    Aiken, S
    Bourhill, G
    TETRAHEDRON, 2002, 58 (12) : 2415 - 2422
  • [26] Simultaneous determination of copper(II), lead(II) and zinc(II) in spectrometry using a wavelet packet transform based generalized regression neural network
    Gao, Ling
    Ren, Shou-Xin
    Yejin Fenxi/Metallurgical Analysis, 2007, 27 (10): : 6 - 10
  • [27] Application of multivariate calibration methods for the simultaneous multiwavelength spectrophotometric determination of Fe(II), Cu(II), Zn(II), and Mn(II) in mixtures
    Ni, Yongnian
    Wang, Yong
    Kokot, Serge
    ANALYTICAL LETTERS, 2007, 40 (06) : 1209 - 1226
  • [28] Complexes of dicamba with cadmium(II), copper(II), mercury(II), lead(II) and zinc(II)
    A. Turek
    J. Kobyłecka
    B. Ptaszyński
    Journal of Thermal Analysis and Calorimetry, 2004, 78 : 513 - 524
  • [29] The fabrication and characterization of a bismuth nanoparticle modified boron doped diamond electrode and its application to the simultaneous determination of cadmium(II) and lead(II)
    Toghill, Kathryn E.
    Wildgoose, Gregory G.
    Moshar, Amir
    Mulcahy, Chris
    Compton, Richard G.
    ELECTROANALYSIS, 2008, 20 (16) : 1731 - 1737