The effect of tin prefiltration on extremity cone-beam CT imaging with a twin robotic X-ray system

被引:5
|
作者
Luetkens, K. S. [1 ]
Hu, H. [1 ]
Kunz, A. S. [1 ]
Ritschl, L. [2 ]
Herbst, M. [2 ]
Kappler, S. [2 ]
Erguen, S. [3 ]
Goertz, L. [4 ,5 ]
Pennig, L. [4 ,5 ]
Bley, T. A. [1 ]
Gassenmaier, T. [1 ]
Grunz, J. -P. [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Siemens Healthcare GmbH, Xray Prod Res & Dev, Siemensstr 1, D-91301 Forchheim, Germany
[3] Univ Wurzburg, Inst Anat & Cell Biol, Koellikerstr 6, D-97070 Wurzburg, Germany
[4] Univ Cologne, Fac Med, Inst Diagnost & Intervent Radiol, Kerpener Str 62, D-50937 Cologne, Germany
[5] Univ Cologne, Univ Hosp Cologne, Kerpener Str 62, D-50937 Cologne, Germany
关键词
Radiation dosage; Cone-beam computed tomography; Extremities; Tin; Filtration; Prefiltration; COMPUTED-TOMOGRAPHY; QUALITY; OPTIMIZATION; FRACTURES; WRIST; BONE;
D O I
10.1016/j.radi.2021.10.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: While tin prefiltration is established in various CT applications, its value in extremity cone beam CT relative to optimized spectra has not been thoroughly assessed thus far. This study aims to investigate the effect of tin filters in extremity cone-beam CT with a twin-robotic X-ray system. Methods: Wrist, elbow and ankle joints of two cadaveric specimens were examined in a laboratory setup with different combinations of prefiltration (copper, tin), tube voltage and current-time product. Image quality was assessed subjectively by five radiologists with Fleiss' kappa being computed to measure interrater agreement. To provide a semiquantitative criterion for image quality, contrast-to-noise ratios (CNR) were compared for standardized regions of interest. Volume CT dose indices were calculated for a 16 cm polymethylmethacrylate phantom. Results: Radiation dose ranged from 17.4 mGy in the clinical standard protocol without tin filter to as low as 0.7 mGy with tin prefiltration. Image quality ratings and CNR for tin-filtered scans with 100 kV were lower than for 80 kV studies with copper prefiltration despite higher dose (11.2 and 5.6 vs. 4.5 mGy; p < 0.001). No difference was ascertained between 100 kV scans with tin filtration and 60 kV copper filtered scans with 75% dose reduction (subjective: p = 0.101; CNR: p = 0.706). Fleiss' kappa of 0.597 (95% confidence interval 0.567-0.626; p < 0.001) indicated moderate interrater agreement. Conclusion: Considerable dose reduction is feasible with tin prefiltration, however, the twin-robotic Xray system's low-dose potential for extremity 3D imaging is maximized with a dedicated low-kilovolt scan protocol in situations without extensive beam-hardening artifacts. Implications for practice: Low-kilovolt imaging with copper prefiltration provides a superior trade-off between dose reduction and image quality compared to tin-filtered cone-beam CT scan protocols with higher tube voltage. (c) 2021 The Author(s). Published by Elsevier Ltd on behalf of The College of Radiographers. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:433 / 439
页数:7
相关论文
共 50 条
  • [41] Micro cone-beam CT scanner based on X-ray polycapillary optics
    Zhou La-Zhen
    Xia Wen-Jing
    Xu Qian-Qian
    Chen Zan
    Li Fang-Zuo
    Liu Zhi-Guo
    Sun Tian-Xi
    ACTA PHYSICA SINICA, 2022, 71 (09)
  • [43] Characterization of spectral X-ray imaging for dental cone-beam computed tomography
    Nasirudin, Radin Adi Aizudin Bin Radin
    Penchev, Petar
    Mei, Kai
    Rummeny, Ernst J.
    Fiebich, Martin
    Noël, Peter B.
    Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 2013, 8668
  • [44] Characterization of spectral x-ray imaging for dental cone-beam computed tomography
    Nasirudin, Radin Adi Aizudin Bin Radin
    Penchev, Petar
    Mei, Kai
    Rummeny, Ernst J.
    Fiebich, Martin
    Noel, Peter B.
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [45] A low-cost geometry calibration procedure for a modular cone-beam X-ray CT system
    Nguyen, V
    De Beenhouwer, J.
    Sanctorum, J. G.
    Van Wassenbergh, S.
    Bazrafkan, S.
    Dirckx, J. J. J.
    Sijbers, J.
    NONDESTRUCTIVE TESTING AND EVALUATION, 2020, 35 (03) : 252 - 265
  • [46] Development and Spatial Resolution Characterization of a Dedicated Pulsed X-ray, Cone-beam Breast CT System
    Gazi, Peymon
    Yang, Kai
    Burkett, Geroge
    Boone, John
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [47] Evaluation of Ultra-High-Resolution Cone-Beam CT Prototype of Twin Robotic Radiography System for Cadaveric Wrist Imaging
    Grunz, Jan-Peter
    Weng, Andreas Max
    Gietzen, Carsten Herbert
    Veyhl-Wichmann, Maike
    Pennig, Lenhard
    Kunz, Andreas
    Schmitt, Rainer
    Erguen, Sueleyman
    Bley, Thorsten Alexander
    Gassenmaier, Tobias
    ACADEMIC RADIOLOGY, 2021, 28 (10) : E314 - E322
  • [48] X-ray scatter correction algorithm for cone beam CT imaging
    Ning, R
    Tang, XY
    Conover, D
    MEDICAL PHYSICS, 2004, 31 (05) : 1195 - 1202
  • [49] REVIEW ON THE DEVELOPMENT OF CONE-BEAM X-RAY MICROTOMOGRAPHY
    CHENG, PC
    LIN, TH
    WANG, G
    SHINOZAKI, DM
    KIM, HG
    NEWBERRY, SP
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1993, (130): : 559 - 566
  • [50] CONE-BEAM X-RAY MICROTOMOGRAPHY OF SMALL SPECIMENS
    MACHIN, K
    WEBB, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (10): : 1639 - 1657