The effect of tin prefiltration on extremity cone-beam CT imaging with a twin robotic X-ray system

被引:5
|
作者
Luetkens, K. S. [1 ]
Hu, H. [1 ]
Kunz, A. S. [1 ]
Ritschl, L. [2 ]
Herbst, M. [2 ]
Kappler, S. [2 ]
Erguen, S. [3 ]
Goertz, L. [4 ,5 ]
Pennig, L. [4 ,5 ]
Bley, T. A. [1 ]
Gassenmaier, T. [1 ]
Grunz, J. -P. [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Siemens Healthcare GmbH, Xray Prod Res & Dev, Siemensstr 1, D-91301 Forchheim, Germany
[3] Univ Wurzburg, Inst Anat & Cell Biol, Koellikerstr 6, D-97070 Wurzburg, Germany
[4] Univ Cologne, Fac Med, Inst Diagnost & Intervent Radiol, Kerpener Str 62, D-50937 Cologne, Germany
[5] Univ Cologne, Univ Hosp Cologne, Kerpener Str 62, D-50937 Cologne, Germany
关键词
Radiation dosage; Cone-beam computed tomography; Extremities; Tin; Filtration; Prefiltration; COMPUTED-TOMOGRAPHY; QUALITY; OPTIMIZATION; FRACTURES; WRIST; BONE;
D O I
10.1016/j.radi.2021.10.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: While tin prefiltration is established in various CT applications, its value in extremity cone beam CT relative to optimized spectra has not been thoroughly assessed thus far. This study aims to investigate the effect of tin filters in extremity cone-beam CT with a twin-robotic X-ray system. Methods: Wrist, elbow and ankle joints of two cadaveric specimens were examined in a laboratory setup with different combinations of prefiltration (copper, tin), tube voltage and current-time product. Image quality was assessed subjectively by five radiologists with Fleiss' kappa being computed to measure interrater agreement. To provide a semiquantitative criterion for image quality, contrast-to-noise ratios (CNR) were compared for standardized regions of interest. Volume CT dose indices were calculated for a 16 cm polymethylmethacrylate phantom. Results: Radiation dose ranged from 17.4 mGy in the clinical standard protocol without tin filter to as low as 0.7 mGy with tin prefiltration. Image quality ratings and CNR for tin-filtered scans with 100 kV were lower than for 80 kV studies with copper prefiltration despite higher dose (11.2 and 5.6 vs. 4.5 mGy; p < 0.001). No difference was ascertained between 100 kV scans with tin filtration and 60 kV copper filtered scans with 75% dose reduction (subjective: p = 0.101; CNR: p = 0.706). Fleiss' kappa of 0.597 (95% confidence interval 0.567-0.626; p < 0.001) indicated moderate interrater agreement. Conclusion: Considerable dose reduction is feasible with tin prefiltration, however, the twin-robotic Xray system's low-dose potential for extremity 3D imaging is maximized with a dedicated low-kilovolt scan protocol in situations without extensive beam-hardening artifacts. Implications for practice: Low-kilovolt imaging with copper prefiltration provides a superior trade-off between dose reduction and image quality compared to tin-filtered cone-beam CT scan protocols with higher tube voltage. (c) 2021 The Author(s). Published by Elsevier Ltd on behalf of The College of Radiographers. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:433 / 439
页数:7
相关论文
共 50 条
  • [21] Twin robotic x-ray system in small bone and joint trauma: impact of cone-beam computed tomography on treatment decisions
    Grunz, Jan-Peter
    Pennig, Lenhard
    Fieber, Tabea
    Gietzen, Carsten Herbert
    Heidenreich, Julius Frederik
    Huflage, Henner
    Gruschwitz, Philipp
    Kuhl, Philipp Josef
    Petritsch, Bernhard
    Kosmala, Aleksander
    Bley, Thorsten Alexander
    Gassenmaier, Tobias
    EUROPEAN RADIOLOGY, 2021, 31 (06) : 3600 - 3609
  • [22] Cone-beam CT imaging for robotic navigation bronchoscopy
    Fielding, David
    van der Heijden, Erik H. F. M.
    RESPIROLOGY, 2024, 29 (04) : 274 - 276
  • [23] Comparison of fan- and cone-beam imaging capabilities on a portable x-ray imaging system
    White, TA
    Roney, T
    Pink, RJ
    Noo, F
    Clackdoyle, R
    Smith, M
    Jones, WF
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 138 - 146
  • [24] A new cone-beam X-ray CT system with a reduced size planar detector
    Li Liang
    Chen Zhi-Qiang
    Zhang Li
    Xing Yu-Xiang
    Kang Ke-Jun
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2006, 30 (08): : 812 - 817
  • [25] X-ray scatter correction algorithm for 450 KeV cone-beam CT system
    Dept. of Engineering Physics, Tsinghua University, Beijing 100084, China
    Hedianzixue Yu Tance Jishue, 2006, 6 (908-911):
  • [26] Evaluation of scatter mitigation strategies for X-ray cone-beam CT
    Lasio, G.
    Williamson, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2288 - 2289
  • [27] Filtered back projection method for cone-beam X-ray CT
    Matsuo, Hiroshi, 1600, (20):
  • [28] FPGA-acceleration of cone-beam reconstruction for the X-ray CT
    Stsepankou, D
    Kornmesser, K
    Hesser, J
    Männer, R
    2004 IEEE INTERNATIONAL CONFERENCE ON FIELD-PROGRAMMABLE TECHNOLOGY, PROCEEDINGS, 2004, : 327 - 330
  • [29] An accelerated RAMLA reconstruction algorithm for X-ray cone-beam CT
    Zhao, Xing
    Hu, Jing-jing
    Yang, Tao
    Wang, Feng
    INSIGHT, 2013, 55 (05) : 237 - 242
  • [30] Coherent Cone-Beam X-ray Microscopy
    Harder, R.
    Xiao, X.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 429 - 432