The effect of tin prefiltration on extremity cone-beam CT imaging with a twin robotic X-ray system

被引:5
|
作者
Luetkens, K. S. [1 ]
Hu, H. [1 ]
Kunz, A. S. [1 ]
Ritschl, L. [2 ]
Herbst, M. [2 ]
Kappler, S. [2 ]
Erguen, S. [3 ]
Goertz, L. [4 ,5 ]
Pennig, L. [4 ,5 ]
Bley, T. A. [1 ]
Gassenmaier, T. [1 ]
Grunz, J. -P. [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Siemens Healthcare GmbH, Xray Prod Res & Dev, Siemensstr 1, D-91301 Forchheim, Germany
[3] Univ Wurzburg, Inst Anat & Cell Biol, Koellikerstr 6, D-97070 Wurzburg, Germany
[4] Univ Cologne, Fac Med, Inst Diagnost & Intervent Radiol, Kerpener Str 62, D-50937 Cologne, Germany
[5] Univ Cologne, Univ Hosp Cologne, Kerpener Str 62, D-50937 Cologne, Germany
关键词
Radiation dosage; Cone-beam computed tomography; Extremities; Tin; Filtration; Prefiltration; COMPUTED-TOMOGRAPHY; QUALITY; OPTIMIZATION; FRACTURES; WRIST; BONE;
D O I
10.1016/j.radi.2021.10.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: While tin prefiltration is established in various CT applications, its value in extremity cone beam CT relative to optimized spectra has not been thoroughly assessed thus far. This study aims to investigate the effect of tin filters in extremity cone-beam CT with a twin-robotic X-ray system. Methods: Wrist, elbow and ankle joints of two cadaveric specimens were examined in a laboratory setup with different combinations of prefiltration (copper, tin), tube voltage and current-time product. Image quality was assessed subjectively by five radiologists with Fleiss' kappa being computed to measure interrater agreement. To provide a semiquantitative criterion for image quality, contrast-to-noise ratios (CNR) were compared for standardized regions of interest. Volume CT dose indices were calculated for a 16 cm polymethylmethacrylate phantom. Results: Radiation dose ranged from 17.4 mGy in the clinical standard protocol without tin filter to as low as 0.7 mGy with tin prefiltration. Image quality ratings and CNR for tin-filtered scans with 100 kV were lower than for 80 kV studies with copper prefiltration despite higher dose (11.2 and 5.6 vs. 4.5 mGy; p < 0.001). No difference was ascertained between 100 kV scans with tin filtration and 60 kV copper filtered scans with 75% dose reduction (subjective: p = 0.101; CNR: p = 0.706). Fleiss' kappa of 0.597 (95% confidence interval 0.567-0.626; p < 0.001) indicated moderate interrater agreement. Conclusion: Considerable dose reduction is feasible with tin prefiltration, however, the twin-robotic Xray system's low-dose potential for extremity 3D imaging is maximized with a dedicated low-kilovolt scan protocol in situations without extensive beam-hardening artifacts. Implications for practice: Low-kilovolt imaging with copper prefiltration provides a superior trade-off between dose reduction and image quality compared to tin-filtered cone-beam CT scan protocols with higher tube voltage. (c) 2021 The Author(s). Published by Elsevier Ltd on behalf of The College of Radiographers. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:433 / 439
页数:7
相关论文
共 50 条
  • [1] Dose reduction potential in cone-beam CT imaging of upper extremity joints with a twin robotic x-ray system
    Karsten Sebastian Luetkens
    Süleyman Ergün
    Henner Huflage
    Andreas Steven Kunz
    Carsten Herbert Gietzen
    Nora Conrads
    Lenhard Pennig
    Lukas Goertz
    Thorsten Alexander Bley
    Tobias Gassenmaier
    Jan-Peter Grunz
    Scientific Reports, 11
  • [2] Dose reduction potential in cone-beam CT imaging of upper extremity joints with a twin robotic x-ray system
    Luetkens, Karsten Sebastian
    Erguen, Sueleyman
    Huflage, Henner
    Kunz, Andreas Steven
    Gietzen, Carsten Herbert
    Conrads, Nora
    Pennig, Lenhard
    Goertz, Lukas
    Bley, Thorsten Alexander
    Gassenmaier, Tobias
    Grunz, Jan-Peter
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [3] Patient Shielding in Ultra-High-Resolution Cone-Beam CT of the Upper Extremity with a Twin Robotic X-Ray System
    Kunz, Andreas Steven
    Weick, Stefan
    Grunz, Jan-Peter
    Toussaint, Andre
    Razinskas, Gary
    Richter, Anne
    Wegener, Sonja
    Wittig-Sauerwein, Andrea
    Bley, Thorsten Alexander
    Huflage, Henner
    DIAGNOSTICS, 2025, 15 (05)
  • [4] Twin robotic x-ray system for 2D radiographic and 3D cone-beam CT imaging
    Fieselmann, Andreas
    Steinbrener, Jan
    Jerebko, Anna K.
    Voigt, Johannes M.
    Scholz, Rosemarie
    Ritschl, Ludwig
    Mertelmeier, Thomas
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [5] Metal artifact reduction in ultra-high-resolution cone-beam CT imaging with a twin robotic X-ray system
    Andreas Steven Kunz
    Theresa Sophie Patzer
    Jan-Peter Grunz
    Karsten Sebastian Luetkens
    Viktor Hartung
    Robin Hendel
    Tabea Fieber
    Franca Genest
    Süleyman Ergün
    Thorsten Alexander Bley
    Henner Huflage
    Scientific Reports, 12
  • [6] Metal artifact reduction in ultra-high-resolution cone-beam CT imaging with a twin robotic X-ray system
    Kunz, Andreas Steven
    Patzer, Theresa Sophie
    Grunz, Jan-Peter
    Luetkens, Karsten Sebastian
    Hartung, Viktor
    Hendel, Robin
    Fieber, Tabea
    Genest, Franca
    Erguen, Suleyman
    Bley, Thorsten Alexander
    Huflage, Henner
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [7] Geometry Repeatability for Diagnostic Cone-Beam Imaging in the Emergency Department Using a Twin Robotic X-Ray System
    Herbst, M.
    Noo, F.
    Fieselmann, A.
    Vogt, S.
    Ritschl, L.
    Mertelmeier, T.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [8] Dedicated Cone-Beam CT System for Extremity Imaging
    Carrino, John A.
    Al Muhit, Abdullah
    Zbijewski, Wojciech
    Thawait, Gaurav K.
    Stayman, J. Webster
    Packard, Nathan
    Senn, Robert
    Yang, Dong
    Foos, David H.
    Yorkston, John
    Siewerdsen, Jeffrey H.
    RADIOLOGY, 2014, 270 (03) : 816 - 824
  • [9] 3D cone-beam CT with a twin robotic x-ray system in elbow imaging: comparison of image quality to high-resolution multidetector CT
    Jan-Peter Grunz
    Andreas Max Weng
    Andreas Steven Kunz
    Maike Veyhl-Wichmann
    Rainer Schmitt
    Carsten Herbert Gietzen
    Lenhard Pennig
    Stefan Herz
    Süleyman Ergün
    Thorsten Alexander Bley
    Tobias Gassenmaier
    European Radiology Experimental, 4
  • [10] 3D cone-beam CT with a twin robotic x-ray system in elbow imaging: comparison of image quality to high-resolution multidetector CT
    Grunz, Jan-Peter
    Weng, Andreas Max
    Kunz, Andreas Steven
    Veyhl-Wichmann, Maike
    Schmitt, Rainer
    Gietzen, Carsten Herbert
    Pennig, Lenhard
    Herz, Stefan
    Erguen, Sueleyman
    Bley, Thorsten Alexander
    Gassenmaier, Tobias
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2020, 4 (01)