Objective: The X-ray and CT features of minimally invasive percutaneous pedicle screw for open reduction and internal fixation and traditional open reduction and internal fixation for thoracolurnbar fractures were compared. Methods: Sixty-two patients with thoracolumbar fractures were analyzed with single vertebral body injury without obvious osteoporosis. Patients were randomly divided into two groups. In group A, minimally invasive percutaneous pedicle screws were used for open reduction and fixation. Group B was treated with thoracolumbar vertebral fracture with traditional incision and reduction and internal fixation with posterolateral fusion. Both groups followed standard surgical methods and methods, the same postoperative treatment and functional exercise plan. Results: During a 9-month follow-up, X-ray and computed tomography were used to analyze fracture joint motion injuries. The recovery rate of vertebral height in group A was significantly better than that in group B. At 9 months after operation, the recovery rate of vertebral height in group A increased. The neural function was similar, but the improvement rate in group A was significantly better than that in group B. Conclusions: Minimally invasive percutaneous pedicle screws for open reduction and internal fixation are compared with traditional open reduction and internal fixation for thoracolumbar fractures. Vertebral body height, symptom improvement, and neurological recovery after a lumbar fracture, However, minimally invasive percutaneous pedicle screws for open reduction and internal fixation can immediately increase the compression stability of the anterior spine and reduce complications such as nail and rod rupture due to excessive fixation pressure.
引用
收藏
页码:2959 / 2964
页数:6
相关论文
共 50 条
  • [41] X-ray induced acoustic computed tomography
    Samant, P.
    Trevisi, L.
    Ji, X.
    Xiang, L.
    PHOTOACOUSTICS, 2020, 19 (19)
  • [42] Accelerating X-ray Fluorescence Computed Tomography
    La Riviere, P. J.
    Vargas, P.
    Fu, G.
    Meng, L. J.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 1000 - +
  • [43] Interlaced X-ray diffraction computed tomography
    Vamvakeros, Antonios
    Jacques, Simon D. M.
    Di Michiel, Marco
    Senecal, Pierre
    Middelkoop, Vesna
    Cernik, Robert J.
    Beale, Andrew M.
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2016, 49 : 485 - 496
  • [44] Adaptive zooming in X-ray computed tomography
    Dabravolski, Andrei
    Batenburg, Kees Joost
    Sijbers, Jan
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (01) : 77 - 89
  • [45] General formulation for X-ray computed tomography
    Wei, Yuchuan
    Yu, Hengyong
    Hsieh, Jiang
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [46] Reciprocal space x-ray computed tomography
    Vailionis, Arturas
    Wu, Liyan
    Spanier, Jonathan E.
    APL MATERIALS, 2024, 12 (05):
  • [47] X-ray computed tomography in life sciences
    Rawson, Shelley D.
    Maksimcuka, Jekaterina
    Withers, Philip J.
    Cartmell, Sarah H.
    BMC BIOLOGY, 2020, 18 (01)
  • [48] X-ray computed tomography of frozen soil
    Torrance, J. K.
    Elliot, T.
    Martin, R.
    Heck, R. J.
    COLD REGIONS SCIENCE AND TECHNOLOGY, 2008, 53 (01) : 75 - 82
  • [49] Image Deblurring using a Joint Entropy Prior in X-ray Luminescence Computed Tomography
    Su, Chang
    Dutta, Joyita
    Zhang, Hui
    El Fakhri, Georges
    Li, Quanzheng
    MEDICAL IMAGING 2017: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2017, 10137
  • [50] IN-SITU FRAGMENT ANALYSIS WITH X-RAY COMPUTED TOMOGRAPHY, XCT
    Wells, J. M.
    ADVANCES IN CERAMIC ARMOR III, 2008, 25 (05): : 181 - 192