X-ray and Computed Tomography Analysis of Spinal Joint Injuries

被引:0
|
作者
Zhang, Hongyi [1 ]
Feng, Haoyu [1 ]
Chen, Chen [1 ]
Zhang, Li [1 ]
Li, Qiang [1 ]
Zhao, Haoliang [1 ]
机构
[1] Shanxi Bethune Hosp, Dept Orthoped Surg, Taiyuan 030032, Shanxi, Peoples R China
关键词
Minimally Invasive Percutaneous Pedicle Screw; Thoracolumbar Fracture; Posterolateral Fusion; Internal Fixation; Medical Image Analysis; CLASSIFICATION;
D O I
10.1166/jmihi.2020.3242
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective: The X-ray and CT features of minimally invasive percutaneous pedicle screw for open reduction and internal fixation and traditional open reduction and internal fixation for thoracolurnbar fractures were compared. Methods: Sixty-two patients with thoracolumbar fractures were analyzed with single vertebral body injury without obvious osteoporosis. Patients were randomly divided into two groups. In group A, minimally invasive percutaneous pedicle screws were used for open reduction and fixation. Group B was treated with thoracolumbar vertebral fracture with traditional incision and reduction and internal fixation with posterolateral fusion. Both groups followed standard surgical methods and methods, the same postoperative treatment and functional exercise plan. Results: During a 9-month follow-up, X-ray and computed tomography were used to analyze fracture joint motion injuries. The recovery rate of vertebral height in group A was significantly better than that in group B. At 9 months after operation, the recovery rate of vertebral height in group A increased. The neural function was similar, but the improvement rate in group A was significantly better than that in group B. Conclusions: Minimally invasive percutaneous pedicle screws for open reduction and internal fixation are compared with traditional open reduction and internal fixation for thoracolumbar fractures. Vertebral body height, symptom improvement, and neurological recovery after a lumbar fracture, However, minimally invasive percutaneous pedicle screws for open reduction and internal fixation can immediately increase the compression stability of the anterior spine and reduce complications such as nail and rod rupture due to excessive fixation pressure.
引用
收藏
页码:2959 / 2964
页数:6
相关论文
共 50 条
  • [21] A numismatic study of Roman coins through X-ray fluorescence and X-ray computed μ-tomography analysis
    Smeriglio, Andrea
    Filosa, Raffaele
    Crocco, Maria Caterina
    Formoso, Vincenzo
    Barberi, Riccardo Cristoforo
    Solano, Andrea
    Cerzoso, Maria
    Polosa, Annalisa
    Cerrone, Valerio
    Agostino, Raffaele Giuseppe
    ACTA IMEKO, 2023, 12 (04):
  • [22] X-ray luminescence computed tomography using a focused x-ray beam
    Zhang, Wei
    Lun, Michael C.
    Nguyen, Alex Anh-Tu
    Li, Changqing
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (11)
  • [23] STATISTICAL ASPECTS OF COMPUTED X-RAY TOMOGRAPHY
    CHESLER, DA
    PELC, NJ
    RIEDERER, SJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (01): : 130 - 131
  • [24] X-ray computed tomography of ultralightweight metals
    Winter, JM
    Green, RE
    Waters, AM
    Green, WH
    RESEARCH IN NONDESTRUCTIVE EVALUATION, 1999, 11 (04) : 199 - 211
  • [25] X-ray computed tomography for medical imaging
    Hiriyannaiah, HP
    IEEE SIGNAL PROCESSING MAGAZINE, 1997, 14 (02) : 42 - 59
  • [26] Contemporary developments in computed X-ray tomography
    Seibert, JA
    RADIOLOGY, 1998, 209P : 207 - 208
  • [27] Microscopic x-ray luminescence computed tomography
    Zhang, Wei
    Zhu, Dianwen
    Zhang, Kun
    Li, Changqing
    MULTIMODAL BIOMEDICAL IMAGING X, 2015, 9316
  • [28] X-ray computed tomography in life sciences
    Shelley D. Rawson
    Jekaterina Maksimcuka
    Philip J. Withers
    Sarah H. Cartmell
    BMC Biology, 18
  • [29] Ptychographic X-ray computed tomography at the nanoscale
    Dierolf, Martin
    Menzel, Andreas
    Thibault, Pierre
    Schneider, Philipp
    Kewish, Cameron M.
    Wepf, Roger
    Bunk, Oliver
    Pfeiffer, Franz
    NATURE, 2010, 467 (7314) : 436 - U82
  • [30] X-Ray Luminescence Computed Tomography Via Selective X-Ray Excitation
    Pratx, G.
    Carpenter, C.
    Sun, C.
    Xing, L.
    MEDICAL PHYSICS, 2010, 37 (06)