X-ray and Computed Tomography Analysis of Spinal Joint Injuries

被引:0
|
作者
Zhang, Hongyi [1 ]
Feng, Haoyu [1 ]
Chen, Chen [1 ]
Zhang, Li [1 ]
Li, Qiang [1 ]
Zhao, Haoliang [1 ]
机构
[1] Shanxi Bethune Hosp, Dept Orthoped Surg, Taiyuan 030032, Shanxi, Peoples R China
关键词
Minimally Invasive Percutaneous Pedicle Screw; Thoracolumbar Fracture; Posterolateral Fusion; Internal Fixation; Medical Image Analysis; CLASSIFICATION;
D O I
10.1166/jmihi.2020.3242
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective: The X-ray and CT features of minimally invasive percutaneous pedicle screw for open reduction and internal fixation and traditional open reduction and internal fixation for thoracolurnbar fractures were compared. Methods: Sixty-two patients with thoracolumbar fractures were analyzed with single vertebral body injury without obvious osteoporosis. Patients were randomly divided into two groups. In group A, minimally invasive percutaneous pedicle screws were used for open reduction and fixation. Group B was treated with thoracolumbar vertebral fracture with traditional incision and reduction and internal fixation with posterolateral fusion. Both groups followed standard surgical methods and methods, the same postoperative treatment and functional exercise plan. Results: During a 9-month follow-up, X-ray and computed tomography were used to analyze fracture joint motion injuries. The recovery rate of vertebral height in group A was significantly better than that in group B. At 9 months after operation, the recovery rate of vertebral height in group A increased. The neural function was similar, but the improvement rate in group A was significantly better than that in group B. Conclusions: Minimally invasive percutaneous pedicle screws for open reduction and internal fixation are compared with traditional open reduction and internal fixation for thoracolumbar fractures. Vertebral body height, symptom improvement, and neurological recovery after a lumbar fracture, However, minimally invasive percutaneous pedicle screws for open reduction and internal fixation can immediately increase the compression stability of the anterior spine and reduce complications such as nail and rod rupture due to excessive fixation pressure.
引用
收藏
页码:2959 / 2964
页数:6
相关论文
共 50 条
  • [1] Image Analysis in X-ray Computed Tomography
    Seletchi, Emilia Dana
    Sutac, Victor
    PROCEEDINGS OF THE 1ST INTERNATIONAL CONFERENCE ON VIRTUAL LEARNING: VIRTUAL LEARNING - VIRTUAL REALITY: MODELS & METHODOLOGIES, TECHNOLOGIES, SOFTWARE SOLUTIONS, 2006, : 187 - +
  • [2] X-RAY COMPUTED TOMOGRAPHY
    HORN, E
    ELECTRONICS AND POWER, 1978, 24 (01): : 36 - 41
  • [3] X-ray computed tomography
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (13): : R29 - R43
  • [4] X-ray computed tomography
    Withers, Philip J.
    Bouman, Charles
    Carmignato, Simone
    Cnudde, Veerle
    Grimaldi, David
    Hagen, Charlotte K.
    Maire, Eric
    Manley, Marena
    Du Plessis, Anton
    Stock, Stuart R.
    NATURE REVIEWS METHODS PRIMERS, 2021, 1 (01):
  • [5] X-ray computed tomography
    Nature Reviews Methods Primers, 1
  • [6] X-RAY COMPUTED TOMOGRAPHY
    HORN, E
    ELECTRONICS AND POWER, 1978, 24 (03): : 181 - 181
  • [7] Tree Core Analysis with X-ray Computed Tomography
    De Mil, Tom
    Van den Bulcke, Jan
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (199):
  • [8] QUANTITATIVE ANALYSIS OF COMPUTED TOMOGRAPHY AND X-RAY IN BRONCHIECTASIS
    Clark, A.
    Byrnes, C.
    RESPIROLOGY, 2014, 19 : 20 - 20
  • [9] High spatial resolution x-ray luminescence computed tomography and x-ray fluorescence computed tomography
    Dai, Xianjin
    Sivasubramanian, Kathyayini
    Xing, Lei
    MOLECULAR-GUIDED SURGERY: MOLECULES, DEVICES, AND APPLICATIONS V, 2019, 10862
  • [10] Industrial X-ray computed tomography
    Pechstein, Torsten