The effect of viewing distance on subjective refraction assessment

被引:1
|
作者
Kucika, Alina [1 ]
Rumjanceva, Ilona [1 ]
Patrova, Tatjana [1 ]
Svede, Aiga [1 ]
机构
[1] Univ Latvia, Dept Optometry & Vis Sci, Fac Phys Math & Optometry, Jelgavas Iela 1, LV-1004 Riga, Latvia
关键词
optometry; viewing distance; subjective refraction; optometric office; visual acuity; VISUAL-ACUITY; ACCOMMODATION; FACILITY; CONTRAST; FOCUS; DEPTH;
D O I
10.3176/proc.2021.4S.02
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Accurate detection of subjective refraction is important to provide patients with the best visual quality. One of the factors affecting detection of subjective refraction is viewing distance. Lack of requirements for optometric office arrangement and required space dimensions leads to smaller optometric offices that provide shorter distance between the patient and the optotype chart. However, the effect of decreased viewing distance on detected subjective refraction remains unknown. The aim of this study was to evaluate the effect of viewing distance on the assessment of subjective refraction. Two types of subjective refraction of the dominant eye were determined in 45 participants at five viewing distances (6 m, 5 m, 4 m, 3 m, and 2.5 m): subjective refraction that ensured visual acuity 1.0 (in decimal units) and maximum subjective refraction that ensured the best corrected visual acuity. The results demonstrated that viewing distance significantly affected the outcome of subjective refraction detection; there were hyperopic shifts in all types of refractions that increased as the viewing distance decreased. To conclude, the most appropriate viewing distance for subjective refraction detection is 5 m or 6 m. If viewing distance is reduced to 4 m or less, a negative spherical lens of the corresponding proximity should be added to the obtained subjective refraction as it cannot be reliably stated that ocular accommodation is fully relaxed. Since this is not always achievable by 0.25 D steps, mirror systems should be used in smaller (3 m and closer viewing distances) optometric offices to provide more appropriate subjective refraction detection.
引用
收藏
页码:317 / 325
页数:9
相关论文
共 50 条
  • [41] Beyond traditional subjective refraction
    Rodriguez-Lopez, Victor
    Dorronsoro, Carlos
    CURRENT OPINION IN OPHTHALMOLOGY, 2022, 33 (03) : 228 - 234
  • [42] Autorefraction versus subjective refraction
    Brown, SM
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (12): : 2243 - 2244
  • [43] Reproducibility of subjective refraction measurement
    Grein, H-J
    Schmidt, O.
    Ritsche, A.
    OPHTHALMOLOGE, 2014, 111 (11): : 1057 - 1064
  • [44] Development of a subjective refraction simulator
    Perches, S.
    Ares, J.
    Collados, M. V.
    8TH IBEROAMERICAN OPTICS MEETING AND 11TH LATIN AMERICAN MEETING ON OPTICS, LASERS, AND APPLICATIONS, 2013, 8785
  • [45] REPEATABILITY OF SUBJECTIVE AND OBJECTIVE REFRACTION
    ROSENFIELD, M
    CHIU, NN
    OPTOMETRY AND VISION SCIENCE, 1995, 72 (08) : 577 - 579
  • [46] Subjective Refraction - Monocular Adjustment
    von Livonius, Bettina
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2021, 238 (09) : 942 - 948
  • [47] Subjective measurement of peripheral refraction
    Colandrea, C.
    Bussa, M. P. B.
    Greco, M.
    Serio, M.
    Chenis, A.
    Gastaldi, M.
    Bellatorre, A.
    DI Benedetto, S.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2024, 47 (05):
  • [48] SUBJECTIVE REFRACTION OF DEAF MUTES
    MILES, PW
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1956, 42 (01) : 127 - 128
  • [49] Global shape integration optotypes for the clinical assessment of visual acuity and subjective refraction
    Leube, Alexander
    Ohlendorf, Arne
    Wahl, Siegfried
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [50] Fast subjective estimation of astigmatism with the Direct Subjective Refraction
    Rodriguez-Lopez, Victor
    Esteban-Ibanez, Eduardo
    Dorronsoro, Carlos
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)