Potentiodynamic Poly(resorcinol)-Modified Glassy Carbon Electrode as a Voltammetric Sensor for Determining Cephalexin and Cefadroxil Simultaneously in Pharmaceutical Formulation and Biological Fluid Samples

被引:16
|
作者
Kassa, Adane [1 ,2 ]
Amare, Meareg [1 ]
Benor, Amare [4 ]
Tigineh, Getinet Tamiru [3 ]
Beyene, Yonas [3 ]
Tefera, Molla [5 ]
Abebe, Atakilt [2 ]
机构
[1] Debre Markos Univ, Coll Nat & Computat Sci, Dept Chem, POB 269, Debre Markos, Ethiopia
[2] Bahir Dar Univ, Dept Chem, POB 79 Bahir Dar, Amhara, Ethiopia
[3] Bahir Dar Univ, Dept Chem, POB 79 Bahir Dar, Amhara, Ethiopia
[4] Bahir Dar Univ, Coll Sci, Dept Phys, POB 79 Bahir Dar, Amhara, Ethiopia
[5] Univ Gondar, Coll Sci, Dept Chem, POB 196, Gondar, Ethiopia
来源
ACS OMEGA | 2022年
关键词
DOSAGE FORM; CEPHALOSPORINS; RESORCINOL; STABILITY; COMPLEXES; KINETICS; BEHAVIOR; LIGAND;
D O I
10.1021/acsomega.2c04514
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study covers the development of a fast, selective, sensitive, and stable method for the simultaneous determination of cephalosporins (cephalexin (CLN) and cefadroxil (CFL)) in biological fluids and tablet samples using potentiodynamic fabrication of a poly(resorcinol)-modified glassy carbon electrode (poly(reso)/GCE). The results of cyclic voltammetry and electrochemical impedance spectroscopy supported the modification of the GCE by a polymer layer that raised the electrode surface area and conductivity. At the poly(reso)/GCE, an irreversible oxidative peak with four-and fivefold current enhancement for CLN and CFL, respectively, at a substantially lower potential demonstrated the catalytic action of the modifier. Under optimized solution and parameters, the peak current response at the poly(reso)/GCE revealed a linear dependence on the concentration of CLN and CFL within the range 0.1-300 and 0.5-300 mu M, respectively, with a limit of detection (LoD) of 3.12 and 8.7 nM, respectively. The levels of CLN in four selected tablet brands and CFL in two tablet brands were in the vicinity of 91.00-103.65% and 97.7-98.83%, respectively, of their nominal values. The recovery results for CLN in pharmaceutical samples were in the range of 99.00-100.67% and for CFL 97.9-99.75% and for blood serum and urine samples 99.55-100.55% and 99.33-100.34% for CLN and 97.13-100.60% and 96.73-102.50% for CFL, respectively. Interference recovery results with errors less than 4.81%, lower LoD, wider dynamic range, excellent recovery results, and good stability of the modifier compared to those for the previously reported methods validated the use of the poly(reso)/GCE for determining CLN and CFL simultaneously in various real samples.
引用
收藏
页码:34599 / 34607
页数:9
相关论文
共 50 条
  • [41] Electrochemical oxidation of ranitidine at poly(dopamine) modified carbon paste electrode: Its voltammetric determination in pharmaceutical and biological samples based on the enhancement effect of anionic surfactant
    Pinar, P. Talay
    Yardim, Y.
    Senturk, Z.
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 273 : 1463 - 1473
  • [42] Sensitive voltammetric determination of riboflavin in pharmaceutical and biological samples using FSN-Zonyl-Nafion modified carbon paste electrode
    Stefanov, Cristina
    Negut, Catalina Cioates
    Gugoasa, Livia Alexandra Dinu
    van Staden, Jacobus Frederick
    MICROCHEMICAL JOURNAL, 2020, 155
  • [43] Gold nanoparticles decorated poly-melamine modified glassy carbon sensor for the voltammetric estimation of domperidone in pharmaceuticals and biological fluids
    Rosy
    Goyal, Rajendra N.
    TALANTA, 2015, 141 : 53 - 59
  • [44] Poly(diphenylamine-4-sulfonic acid) modified glassy carbon electrode for voltammetric determination of gallic acid in honey and peanut samples
    Bitew, Zelalem
    Kassa, Adane
    Misgan, Beyene
    ARABIAN JOURNAL OF CHEMISTRY, 2022, 15 (07)
  • [45] Advanced CuMnCr-LDH modified glassy carbon electrode for simultaneous electrochemical quantification of cabotegravir and paracetamol in biological and pharmaceutical samples
    Bouali, Wiem
    Genc, Asena Ayse
    Erk, Nevin
    Ahmed, Hassan Elzain Hassan
    Soylak, Mustafa
    MICROCHEMICAL JOURNAL, 2025, 212
  • [46] Rod-like CuO nanoparticles/waste masks carbon modified glassy carbon electrode as a voltammetric nanosensor for the sensitive determination of anti-cancer drug pazopanib in biological and pharmaceutical samples
    Bilge, Selva
    Dogan-Topal, Burcu
    Atici, Esen Bellur
    Sinag, Ali
    Ozkan, Sibel A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 343
  • [47] Dysprosium Nanowire Modified Carbon Paste Electrode for the Simultaneous Determination of Naproxen and Paracetamol: Application in Pharmaceutical Formulation and Biological Fluid
    Norouzi, Parviz
    Dousty, Faezeh
    Ganjali, Mohammad Reza
    Daneshgar, Parandis
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2009, 4 (10): : 1373 - 1386
  • [48] Voltammetric sensor based on glassy carbon electrode modified with hierarchical porous carbon, silver sulfide nanoparticles and fullerene for electrochemical monitoring of nitrite in food samples
    Wong, Ademar
    Santos, Anderson M.
    Cardenas-Riojas, Andy A.
    Baena-Moncada, Angelica M.
    Sotomayor, Maria D. P. T.
    FOOD CHEMISTRY, 2022, 383
  • [49] Modification of glassy carbon electrode with poly(hydroxynaphthol blue)/multi-walled carbon nanotubes composite and construction a new voltammetric sensor for the simultaneous determination of hydroquinone, catechol, and resorcinol
    Daneshinejad, Hassan
    Chamjangali, Mansour Arab
    Goudarzi, Nasser
    Amin, Amir Hossain
    MATERIALS RESEARCH EXPRESS, 2018, 5 (03):
  • [50] Differential pulse voltammetric determination of ciprofibrate in pharmaceutical formulations using a glassy carbon electrode modified with functionalized carbon nanotubes within a poly(allylamine hydrochloride) film
    Takeda, Humberto H.
    Janegitz, Bruno C.
    Medeiros, Roberta A.
    Mattoso, Luiz H. C.
    Fatibello-Filho, Orlando
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01): : 755 - 760