Advanced CuMnCr-LDH modified glassy carbon electrode for simultaneous electrochemical quantification of cabotegravir and paracetamol in biological and pharmaceutical samples

被引:0
|
作者
Bouali, Wiem [1 ,2 ]
Genc, Asena Ayse [1 ,2 ]
Erk, Nevin [1 ]
Ahmed, Hassan Elzain Hassan [3 ]
Soylak, Mustafa [3 ,4 ,5 ]
机构
[1] Ankara Univ, Fac Pharm, Dept Analyt Chem, TR-06560 Ankara, Turkiye
[2] Ankara Univ, Grad Sch Hlth Sci, TR-06110 Ankara, Turkiye
[3] Erciyes Univ, Fac Sci, Dept Chem, TR-38039 Kayseri, Turkiye
[4] Erciyes Univ, Technol Res & Applicat Ctr TAUM, TR-38039 Kayseri, Turkiye
[5] Turkish Acad Sci TUBA, Ankara, Turkiye
关键词
CuMnCr-LDH nanocomposite; Simultaneous electrochemical detection; Cabotegravir; Paracetamol; Pharmaceutical sample analysis; Biological sample analysis; LAYERED DOUBLE HYDROXIDE; SENSOR; FORMS;
D O I
10.1016/j.microc.2025.113267
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The simultaneous detection of antiviral and analgesic drugs in biological samples is critical for effective drug therapy monitoring. In this study, a novel electrochemical sensor was developed for the concurrent determination of the antiviral drug Cabotegravir (CABO) and the analgesic Paracetamol (PARA). The sensor was fabricated by modifying a glassy carbon electrode (GCE) with a CuMnCr-LDH nanocomposite, which served as an efficient electrocatalyst. The electrochemical properties of the modified electrode were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The novel CuMnCr-LDH composite exhibits exceptional electrocatalytic activity due to its numerous active sites, reduced charge-transfer resistance, and rapid electron transfer. The sensor's performance for simultaneous CABO and PARA detection was assessed using CV and differential pulse voltammetry (DPV) techniques. Under optimized conditions, the sensor demonstrated excellent sensitivity with linear ranges of 0.06-28.3 mu M for CABO and 0.4-53 mu M for PARA and detection limits (LOD) of 0.028 mu M and 0.19 mu M, respectively. Furthermore, the sensor demonstrated excellent reliability and accuracy when applied to pharmaceutical and biological samples, showcasing its potential for real-world applications in clinical and pharmaceutical settings.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Bilayered Film Modified Glassy Carbon Electrode for the Simultaneous Determination of Paracetamol and Chloroquine in Pharmaceutical and Biological Samples
    Gashu, Mulu
    Aragaw, Belete Asefa
    Tefera, Molla
    Abebe, Atakilt
    ACS OMEGA, 2025, 10 (06): : 5601 - 5615
  • [2] Electrochemical sensor based on a glassy carbon electrode modified with a 3D carbon nanoporous composite for the detection of paracetamol in pharmaceutical samples
    Rodriguez, J. A. Cabas
    Bonetto, A.
    Alaniz, R. D.
    Zon, M. A.
    Pierini, G. D.
    Rodriguez, R. Coneo
    Planes, G.
    Fernandez, H.
    Arevalo, F. J.
    Granero, A. M.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2024, 973
  • [3] Simultaneous voltammetric determination of tramadol and paracetamol exploiting glassy carbon electrode modified with FeNi3 nanoalloy in biological and pharmaceutical media
    Hajmalek, Saeed
    Jahani, Shohreh
    Foroughi, Mohammad Mehdi
    CHEMISTRYSELECT, 2021, 6 (33): : 8797 - 8808
  • [4] Simultaneous determination of paracetamol and ciprofloxacin in biological fluid samples using a glassy carbon electrode modified with graphene oxide and nickel oxide nanoparticles
    Santos, Anderson Martin
    Wong, Ademar
    Almeida, Adriana Araujo
    Fatibello-Filho, Orlando
    TALANTA, 2017, 174 : 610 - 618
  • [5] Simultaneous Electrochemical Determination of Paracetamol and Caffeine using Activated Glassy Carbon Electrode
    Feyisa, Tilahun Yai
    Kitte, Shimeles Addisu
    Yenealem, Dereje
    Gebretsadik, Gebru
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2020, 12 (01): : 93 - 106
  • [6] Electrochemical detection of riociguat using COF-PTA@CuCoFe-LDH modified glassy carbon electrode: A novel approach for pharmaceutical and biological analysis
    Ozata, Cigdem Aybuke
    Erk, Nevin
    Bouali, Wiem
    Genc, Asena Ayse
    Ahmed, Hassan Elzain Hassan
    Matin, Amir Abbas
    Soylak, Mustafa
    MICROCHEMICAL JOURNAL, 2025, 211
  • [7] Modified glassy carbon electrode with multiwall carbon nanotubes as a voltammetric sensor for determination of noscapine in biological and pharmaceutical samples
    Rezaei, Behzad
    Zare, S. Zohreh Mirahmadi
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (01): : 292 - 299
  • [8] Modified glassy carbon electrode with multiwall carbon nanotubes as a voltammetric sensor for determination of leucine in biological and pharmaceutical samples
    Rezaei, B.
    Zare, Z. Mirahmadi
    ANALYTICAL LETTERS, 2008, 41 (12) : 2267 - 2286
  • [9] Electrochemical Determination of Chlorophenaramine Based on RTIL/CNT Composite Modified Glassy Carbon Electrode in Pharmaceutical Samples
    Khan, Shirinaz I.
    Motghare, Ramani V.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (13) : B1202 - B1208
  • [10] Chemically modified glassy carbon electrode for electrochemical sensing paracetamol in acidic solution
    Guocheng Yang
    Lu Wang
    Jianbo Jia
    Defeng Zhou
    Dongfeng Li
    Journal of Solid State Electrochemistry, 2012, 16 : 2967 - 2977