Analysis of a two stage pulse tube cooler by modeling with thermoacoustic theory

被引:0
|
作者
Hofmann, A [1 ]
Wild, S [1 ]
机构
[1] Forschungszentrum Karlsruhe, Inst Tech Phys, D-76021 Karlsruhe, Germany
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
A two stage pulse tube cooler operated with magnetic valves has been tested. The no-load temperature is close to 6 K, and with powers of 4 W and 15 W at the first and second stage, the respective temperatures are 20 K and about 60 K. Additionally, temperatures and pressures have been measured at different positions. This system is being analysed by calculations based on a linearized thermoacoustic theory. Reasonable agreement is obtained when some parameters are fitted. Moreover, the calculations give valuable information on volume flow, pressure drop, phase angles, energy flows, and temperatures at all positions of the system. Those results will be discussed with respect to further optimisation of such systems.
引用
收藏
页码:369 / 377
页数:9
相关论文
共 50 条
  • [41] NUMERICAL ANALYSIS ON THERMOACOUSTIC PRIME MOVERS FOR DEVELOPMENT OF PULSE TUBE CRYOCOOLERS
    Behera, U.
    Kasthurirengan, S.
    Skaria, Mathew
    Shafi, K. A.
    Kamble, B. V.
    Kuzhiveli, Biju. T.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B, 2012, 1434 : 451 - 458
  • [42] Validation of the Pulse Tube Refrigerator Model against a Lockheed pulse tube cooler
    Yuan, SWK
    CRYOGENICS, 1996, 36 (10) : 871 - 877
  • [43] Numerical and experimental study of an annular pulse tube used in the pulse tube cooler
    Pang, Xiaomin
    Chen, Yanyan
    Wang, Xiaotao
    Dai, Wei
    Luo, Ercang
    ADVANCES IN CRYOGENIC ENGINEERING, 2017, 278
  • [44] High capacity staged pulse tube cooler
    Jaco, C
    Nguyen, T
    Colbert, R
    Pietrzak, T
    Chan, CK
    Tward, E
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS. 49A AND B, 2004, 710 : 1263 - 1268
  • [45] IMAS pulse tube cooler development and testing
    Chan, CK
    Nguyen, T
    Colbert, R
    Raab, J
    Ross, RG
    Johnson, DL
    CRYOCOOLERS 10, 1999, : 139 - 147
  • [46] Pressure drop in pulse tube cooler components
    Chen, HE
    Bennett, JH
    Yoshida, S
    Le, A
    Frederking, THK
    CRYOCOOLERS 10, 1999, : 275 - 280
  • [47] Pulse tube cooler for flight hyperspectral imaging
    TRW Space and Technology Division, Space Electronics Grp., One Space P., Redondo Beach, CA 90278, United States
    Cryogenics, 12 (1007-1014):
  • [48] Pulse tube cooler for flight hyperspectral imaging
    Chan, CK
    Clancy, P
    Godden, J
    CRYOGENICS, 1999, 39 (12) : 1007 - 1014
  • [49] A computational model for two-stage 4K-pulse tube cooler: Part II. Predicted results
    Y. L. Ju
    A. T. A. M. de Waele
    Journal of Thermal Science, 2002, 11 : 74 - 79
  • [50] A Computational Model for Two-Stage 4K-Pulse Tube Cooler: Part II. Predicted Results
    Ju, Y. L.
    de Waele, A. T. A. M.
    JOURNAL OF THERMAL SCIENCE, 2002, 11 (01) : 74 - 79