Analysis of a two stage pulse tube cooler by modeling with thermoacoustic theory

被引:0
|
作者
Hofmann, A [1 ]
Wild, S [1 ]
机构
[1] Forschungszentrum Karlsruhe, Inst Tech Phys, D-76021 Karlsruhe, Germany
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
A two stage pulse tube cooler operated with magnetic valves has been tested. The no-load temperature is close to 6 K, and with powers of 4 W and 15 W at the first and second stage, the respective temperatures are 20 K and about 60 K. Additionally, temperatures and pressures have been measured at different positions. This system is being analysed by calculations based on a linearized thermoacoustic theory. Reasonable agreement is obtained when some parameters are fitted. Moreover, the calculations give valuable information on volume flow, pressure drop, phase angles, energy flows, and temperatures at all positions of the system. Those results will be discussed with respect to further optimisation of such systems.
引用
收藏
页码:369 / 377
页数:9
相关论文
共 50 条
  • [21] Comparison of two different ways of using inertance tube in a pulse tube cooler
    Dai, W
    Hu, JY
    Luo, EC
    CRYOGENICS, 2006, 46 (04) : 273 - 277
  • [22] A large cooling capacity single stage coaxial Pulse Tube Cooler
    Poncet, JM
    Trollier, T
    Ravex, A
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 47, PTS A AND B, 2002, 613 : 677 - 682
  • [23] Studies on the development and efficiency improvement of a 1.5 W at 25 K two stage pulse tube cooler
    Kranthi Kumar, J.
    Jacob, S.
    Karunanithi, R.
    Narasimham, G. S. V. L.
    26TH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE & INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2016, 2017, 171
  • [24] Two-stage pulse tube cooler for operation of a Josephson voltage standard near 4 K
    Qiu, LM
    Thummes, G
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 47, PTS A AND B, 2002, 613 : 625 - 632
  • [25] A single-stage pulse tube cooler reached 12.6 K
    Qiu, LM
    He, YL
    Gan, ZH
    Chen, GB
    CRYOGENICS, 2005, 45 (09) : 641 - 643
  • [26] Miniature pulse tube cooler
    Tward, E
    Nguyen, T
    Godden, J
    Toma, G
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS. 49A AND B, 2004, 710 : 1326 - 1329
  • [27] Cryogen free operation of a niobium-tin magnet using a two-stage pulse tube cooler
    Wang, C.
    Thummes, G.
    Heiden, C.
    Best, K.-J.
    Oswald, B.
    IEEE Transactions on Applied Superconductivity, 1999, 9 (2 I): : 402 - 405
  • [28] A completely co-axial two-stage pulse tube cooler working at liquid hydrogen temperatures
    Pang, Xiaomin
    Dai, Wei
    Ma, Suxia
    Wang, Xiaotao
    CHINESE SCIENCE BULLETIN-CHINESE, 2021, 66 (20): : 2629 - 2634
  • [29] Cryogen free operation of a niobium-tin magnet using a two-stage pulse tube cooler
    Wang, C
    Thummes, G
    Heiden, C
    Best, KJ
    Oswald, B
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 402 - 405
  • [30] A Computational Model for Two-Stage 4K-Pulse Tube Cooler: Part Ⅱ. Predicted Results
    Y.L.Ju (Cryogenic Laboratory
    JournalofThermalScience, 2002, (01) : 74 - 79