Analysis of a two stage pulse tube cooler by modeling with thermoacoustic theory

被引:0
|
作者
Hofmann, A [1 ]
Wild, S [1 ]
机构
[1] Forschungszentrum Karlsruhe, Inst Tech Phys, D-76021 Karlsruhe, Germany
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
A two stage pulse tube cooler operated with magnetic valves has been tested. The no-load temperature is close to 6 K, and with powers of 4 W and 15 W at the first and second stage, the respective temperatures are 20 K and about 60 K. Additionally, temperatures and pressures have been measured at different positions. This system is being analysed by calculations based on a linearized thermoacoustic theory. Reasonable agreement is obtained when some parameters are fitted. Moreover, the calculations give valuable information on volume flow, pressure drop, phase angles, energy flows, and temperatures at all positions of the system. Those results will be discussed with respect to further optimisation of such systems.
引用
收藏
页码:369 / 377
页数:9
相关论文
共 50 条
  • [1] Two stage pulse tube cooler for space applications
    Nguyen, T
    Orsini, R
    Toma, G
    Pietrzak, T
    Tward, E
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS. 49A AND B, 2004, 710 : 1347 - 1352
  • [2] High capacity two-stage coaxial pulse tube cooler
    Jaco, C.
    Nguyen, T.
    Tward, E.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 53A AND 53B, 2008, 985 : 530 - 537
  • [3] CHARACTERIZATION OF A TWO-STAGE PULSE TUBE COOLER FOR SPACE APPLICATIONS
    Orsini, R.
    Nguyen, T.
    Colbert, R.
    Raab, J.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 55A AND 55B, 2010, 1218 : 410 - 417
  • [4] An integral hybrid two-stage pulse tube cooler with improved efficiency
    Pang, Xiaomin
    Wang, Xiaotao
    Dai, Wei
    Luo, Ercang
    Li, Haibing
    Ma, Suxia
    CRYOGENICS, 2019, 98 : 107 - 112
  • [5] Performance study on a two-stage 4 K pulse tube cooler
    Wang, C
    Thummes, G
    Heiden, C
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 43 PTS A AND B, 1998, 43 : 2055 - 2062
  • [6] A two-stage pulse tube cooler operating below 4 K
    Wang, C
    Thummes, G
    Heiden, C
    CRYOGENICS, 1997, 37 (03) : 159 - 164
  • [7] Study of staging method for a 25 K two stage pulse tube cooler
    Kumar, Kranthi J.
    Jacob, S.
    Karunanithi, R.
    Narasimham, G. S. V. L.
    27TH INTERNATIONAL CRYOGENICS ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2018 (ICEC-ICMC 2018), 2019, 502
  • [8] Thermoacoustic analysis of a pulse tube refrigerator
    Biwa, T.
    26TH INTERNATIONAL CONFERENCE ON LOW TEMPERATURE PHYSICS (LT26), PTS 1-5, 2012, 400
  • [9] Characteristics of a miniature pulse tube cooler driven by thermoacoustic standing wave engine
    Dai, Wei
    Luo, Ercang
    Zhou, Yuan
    Zhu, Wenxiu
    ICEC 20: PROCEEDINGS OF THE TWENTIETH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE, 2005, : 309 - 312
  • [10] GM-type two-stage pulse tube cooler with high efficiency
    Hofmann, A
    Pan, H
    Oellrich, L
    CRYOCOOLERS 11, 2001, : 221 - 227