Comparison between a screen-film system and a selenium radiography system - An ROC study using simulated thoracic lesions

被引:5
|
作者
Kotter, E [1 ]
Einert, A [1 ]
Merz, C [1 ]
Allmann, KH [1 ]
Altehoefer, C [1 ]
Ghanem, N [1 ]
Langer, M [1 ]
机构
[1] Freiburg Univ Hosp, Dept Diagnost Radiol, D-79106 Freiburg, Germany
关键词
phantoms; radiography; digital; technology; receiver operating characteristics curve; thorax;
D O I
10.1097/00004424-199904000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. TO evaluate the diagnostic image quality of the hard copies of a commercially available selenium detector-based computed radiography system compared to that of a conventional screen-film system, METHODS. Ten radiographs of an anthropomorphic chest phantom with simulated nodular and linear-reticular lesions were produced using either system, Each radiograph was sub-divided into 15 fields containing zero lesions, one nodular lesion, one linear-reticular lesion, or both lesions, The total or 150 Gelds for each modality was reviewed by six radiologists, and receiver operating analysis was performed, RESULTS. The conventional screen-film system performed significantly better for nodular lesions, whereas no statistically significant difference was found between the detection rates of both systems for linear-reticular lesions, CONCLUSIONS. The better detection of nodules with the dedicated selenium detector can be explained by the higher dynamic range of the system, Detection of linear-reticular lesions was slightly but not significantly better with the screen-film system, but the detection rate of the selenium detector might be further improved with a different image processing technique.
引用
收藏
页码:296 / 302
页数:7
相关论文
共 50 条
  • [31] Determination of radiotherapy X-ray spectra using a screen-film system
    Garnica-Garza, H. M.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2008, 46 (10) : 1029 - 1037
  • [32] Performance of a new digital flat panel detector in the detection of artificial bone lesions: A comparison with conventional screen-film radiography and phosphor-storage radiography
    Ludwig, K
    Lenzen, H
    Kamm, K
    Link, TM
    Diederich, S
    Wormanns, D
    RADIOLOGY, 2000, 217 : 517 - 517
  • [33] Determination of radiotherapy X-ray spectra using a screen-film system
    H. M. Garnica-Garza
    Medical & Biological Engineering & Computing, 2008, 46 : 1029 - 1037
  • [34] Impact of a CAD system in a screen-film mammography screening program: A prospective study
    Sanchez Gomez, S.
    Torres Tabanera, M.
    Vega Bolivar, A.
    Sainz Miranda, M.
    Baroja Mazo, A.
    Ruiz Diaz, M.
    Martinez Miravete, P.
    Lag Asturiano, E.
    Munoz Cacho, P.
    Delgado Macias, T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) : E317 - E321
  • [35] Comparison of selenium-based digital and conventional screen-film chest radiography in the depiction of normal anatomy and CT-proved pathology
    Woodard, PK
    Slone, RM
    Gierada, DS
    Reiker, GG
    Jost, RG
    RADIOLOGY, 1996, 201 : 1468 - 1468
  • [36] Computed radiography versus screen-film mammography in detection of simulated microcalcifications: A receiver operating characteristic study based on phantom images
    Shaw, CC
    Wang, TP
    King, JL
    Breitenstein, DS
    Chang, TS
    Harris, KM
    Baratz, AB
    Ganott, MA
    Reginella, R
    Sumkin, JH
    Gur, D
    ACADEMIC RADIOLOGY, 1998, 5 (03) : 173 - 180
  • [37] PERFORMANCE-CHARACTERISTICS OF A LOW-NOISE, HIGH-CONTRAST SCREEN-FILM SYSTEM FOR EQUALIZATION RADIOGRAPHY
    VANMETTER, R
    DICKERSON, RE
    RADIOLOGY, 1992, 185 : 250 - 250
  • [38] Comparison of conventional screen-film mammography and a direct digital magnification system: Detection of simulated small masses and calcifications with usual and reduced dose
    Hermann, K
    Funke, M
    Grabbe, EH
    RADIOLOGY, 1999, 213P : 368 - 368
  • [39] Evaluation of the diagnostic value of a computed radiography system by comparison of digital hard copy images with screen-film mammography: results of a prospective clinical trial
    Van Ongeval, C
    Bosmans, H
    Van Steen, A
    Joossens, K
    Celis, V
    Van Goethem, M
    Verslegers, I
    Nijs, K
    Rogge, F
    Marchal, G
    EUROPEAN RADIOLOGY, 2006, 16 (06) : 1360 - 1366
  • [40] Performance of a flat-panel detector in detecting artificial bone lesions: Comparison with conventional screen-film and storage-phosphor radiography
    Ludwig, K
    Lenzen, H
    Kamm, KF
    Link, TM
    Diederich, S
    Wormanns, D
    Heindel, W
    RADIOLOGY, 2002, 222 (02) : 453 - 459