Comparison between a screen-film system and a selenium radiography system - An ROC study using simulated thoracic lesions

被引:5
|
作者
Kotter, E [1 ]
Einert, A [1 ]
Merz, C [1 ]
Allmann, KH [1 ]
Altehoefer, C [1 ]
Ghanem, N [1 ]
Langer, M [1 ]
机构
[1] Freiburg Univ Hosp, Dept Diagnost Radiol, D-79106 Freiburg, Germany
关键词
phantoms; radiography; digital; technology; receiver operating characteristics curve; thorax;
D O I
10.1097/00004424-199904000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. TO evaluate the diagnostic image quality of the hard copies of a commercially available selenium detector-based computed radiography system compared to that of a conventional screen-film system, METHODS. Ten radiographs of an anthropomorphic chest phantom with simulated nodular and linear-reticular lesions were produced using either system, Each radiograph was sub-divided into 15 fields containing zero lesions, one nodular lesion, one linear-reticular lesion, or both lesions, The total or 150 Gelds for each modality was reviewed by six radiologists, and receiver operating analysis was performed, RESULTS. The conventional screen-film system performed significantly better for nodular lesions, whereas no statistically significant difference was found between the detection rates of both systems for linear-reticular lesions, CONCLUSIONS. The better detection of nodules with the dedicated selenium detector can be explained by the higher dynamic range of the system, Detection of linear-reticular lesions was slightly but not significantly better with the screen-film system, but the detection rate of the selenium detector might be further improved with a different image processing technique.
引用
收藏
页码:296 / 302
页数:7
相关论文
共 50 条
  • [11] Physical and Clinical Comparison between a Screen-Film System and a Dual-Side Reading Mammography-Dedicated Computed Radiography System
    Rivetti, S.
    Canossi, B.
    Battista, R.
    Lanconelli, N.
    Vetruccio, E.
    Danielli, C.
    Borasi, G.
    Torricelli, P.
    ACTA RADIOLOGICA, 2009, 50 (10) : 1109 - U137
  • [12] A RARE-EARTH SCREEN-FILM SYSTEM FOR DENTAL PANORAMIC RADIOGRAPHY
    KEUR, JJ
    AUSTRALIAN DENTAL JOURNAL, 1983, 28 (02) : 105 - 108
  • [13] Selenium-based digital radiography of the cervical spine: comparison with screen-film radiography for the depiction of anatomic details
    Ludwig, K
    Diederich, S
    Wormanns, D
    Link, TM
    Lenzen, H
    Heindel, W
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (08): : 1028 - 1032
  • [14] RELATIONSHIP BETWEEN SCREEN-FILM SYSTEM AND GEOMETRIC UNSHARPNESS - CONVENTIONAL AND 350 KVP CHEST RADIOGRAPHY
    HAUS, AG
    MEYER, J
    NORTH, LB
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1980, 134 (01) : 202 - 202
  • [15] Radiation exposure of the abdominal radiograph using digital luminescence radiography and screen-film system - An animal study.
    Seifert, H
    Schneider, G
    Kubale, R
    Blass, G
    Kramann, B
    Leetz, HK
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1996, 165 (04): : 386 - 391
  • [16] COMPARISON OF STEREOSCOPICALLY ACQUIRED CHEST IMAGES WITH USE OF STORAGE PHOSPHOR RADIOGRAPHY AND AN ASYMMETRIC SCREEN-FILM SYSTEM
    HARTMAN, TE
    AUGHENBAUGH, GL
    BROWN, LR
    HARMS, GF
    KARSELL, PR
    MILLER, WE
    RADIOLOGY, 1995, 197 : 525 - 525
  • [17] Pelvic imaging with a selenium-based detector (Thoravision) - Comparison with screen-film radiography in 75 patients
    Winterer, JT
    Kotter, E
    Einert, A
    Gimpel, S
    Neumann, K
    Laubenberger, J
    Uhrmeister, P
    Langer, M
    INVESTIGATIVE RADIOLOGY, 1999, 34 (12) : 761 - 766
  • [18] COMPARISON OF THEORY AND EXPERIMENT FOR THE DQE OF A RADIOGRAPHIC SCREEN-FILM SYSTEM
    BUNCH, PC
    HUFF, KE
    SHAW, R
    VANMETTER, RL
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1985, 535 : 166 - 183
  • [19] COMPARISON OF THE IMAGE QUALITY OF A HIGH-RESOLUTION SCREEN-FILM SYSTEM AND A DIGITAL FLAT PANEL DETECTOR SYSTEM IN AVIAN RADIOGRAPHY
    Bochmann, Monika
    Ludewig, Eberhard
    Krautwald-Junghanns, Maria-Elisabeth
    Pees, Michael
    VETERINARY RADIOLOGY & ULTRASOUND, 2011, 52 (03) : 256 - 261
  • [20] COMPARISON OF THE LOW-CONTRAST DETECTABILITY OF A SCREEN-FILM SYSTEM AND 3RD-GENERATION COMPUTED RADIOGRAPHY
    COOK, LT
    INSANA, MF
    MCFADDEN, MA
    HALL, TJ
    COX, GG
    MEDICAL PHYSICS, 1994, 21 (05) : 691 - 695