Improved performance lead iodide nuclear radiation detectors

被引:61
|
作者
Deich, V [1 ]
Roth, M [1 ]
机构
[1] HEBREW UNIV JERUSALEM,SCH APPL SCI,IL-91904 JERUSALEM,ISRAEL
关键词
D O I
10.1016/S0168-9002(96)00303-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Melt-grown lead iodide single crystals with an improved transport of positive charge carriers (holes) have been developed. It is shown that an energy resolution of about 3% can be obtained for gamma-radiation at 60 keV (Am-241 isotope source). Improvement of the spectrometric performance of lead iodide detectors at lower gamma-ray energies has been achieved as well due to better purification of the starting material and optimization of the etching procedure. Correlation between the detector performance and the structure of lead iodide crystals has been studied using X-ray diffraction analysis.
引用
收藏
页码:169 / 172
页数:4
相关论文
共 50 条
  • [31] Characterization of lead iodide for nuclear spectrometers
    Schlesinger, T.E.
    James, R.B.
    Schieber, M.
    Toney, J.
    Van Scyoc, J.M.
    Salary, L.
    Hermon, H.
    Lund, J.
    Burger, A.
    Chen, K.-T.
    Cross, E.
    Soria, E.
    Shah, K.
    Squillante, M.
    Yoon, H.
    et. al.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996, 380 (1-2): : 193 - 197
  • [32] Characterization of lead iodide for nuclear spectrometers
    Schlesinger, TE
    James, RB
    Schieber, M
    Toney, J
    VanScyoc, JM
    Salary, L
    Hermon, H
    Lund, J
    Burger, A
    Chen, KT
    Cross, E
    Soria, E
    Shah, K
    Squillante, M
    Yoon, H
    Goorsky, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2): : 193 - 197
  • [33] Lead iodide optical detectors for gamma ray spectroscopy
    Shah, KS
    Bennett, P
    Klugerman, M
    Moy, L
    Cirignano, L
    Dmitriyev, Y
    Squillante, MR
    Olschner, F
    Moses, WW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 448 - 450
  • [34] Lead iodide optical detectors for gamma ray spectroscopy
    Shah, KS
    Bennett, P
    Klugerman, M
    Moy, L
    Cirignano, L
    Dmitriyev, Y
    Squillante, MR
    Olschner, F
    Moses, WW
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 21 - 24
  • [35] SEMICONDUCTOR NUCLEAR RADIATION DETECTORS
    PARKER, RP
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (04): : 605 - +
  • [36] Radiation detectors in nuclear medicine
    Ranger, NT
    RADIOGRAPHICS, 1999, 19 (02) : 481 - 502
  • [37] DIAMOND NUCLEAR RADIATION DETECTORS
    KOZLOV, SF
    BELCARZ, E
    HAGEALI, M
    STUCK, R
    SIFFERT, P
    NUCLEAR INSTRUMENTS & METHODS, 1974, 117 (01): : 277 - 283
  • [38] SEMICONDUCTOR NUCLEAR RADIATION DETECTORS
    TAVENDALE, AJ
    ANNUAL REVIEW OF NUCLEAR SCIENCE, 1967, 17 : 73 - +
  • [39] SILICON DETECTORS FOR NUCLEAR RADIATION
    KEMMER, JA
    SENSORS AND ACTUATORS, 1988, 15 (02): : 169 - 184
  • [40] INI NUCLEAR RADIATION DETECTORS
    SQUILLANTE, MR
    ZHOU, C
    ZHANG, J
    MOY, LP
    SHAH, KS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 364 - 366