Improved performance lead iodide nuclear radiation detectors

被引:61
|
作者
Deich, V [1 ]
Roth, M [1 ]
机构
[1] HEBREW UNIV JERUSALEM,SCH APPL SCI,IL-91904 JERUSALEM,ISRAEL
关键词
D O I
10.1016/S0168-9002(96)00303-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Melt-grown lead iodide single crystals with an improved transport of positive charge carriers (holes) have been developed. It is shown that an energy resolution of about 3% can be obtained for gamma-radiation at 60 keV (Am-241 isotope source). Improvement of the spectrometric performance of lead iodide detectors at lower gamma-ray energies has been achieved as well due to better purification of the starting material and optimization of the etching procedure. Correlation between the detector performance and the structure of lead iodide crystals has been studied using X-ray diffraction analysis.
引用
收藏
页码:169 / 172
页数:4
相关论文
共 50 条
  • [21] THE DEVELOPMENT OF MERCURIC IODIDE GAMMA-RADIATION DETECTORS FOR APPLICATION IN NUCLEAR-MEDICINE
    LEVI, A
    ROTH, M
    SCHIEBER, M
    LAVY, S
    COOPER, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (01) : 457 - 460
  • [22] NUCLEAR RADIATION DETECTORS
    MORTON, GA
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1962, 50 (05): : 1266 - +
  • [23] INTRODUCTION TO 5TH INTERNATIONAL WORKSHOP ON MERCURIC IODIDE NUCLEAR RADIATION DETECTORS
    SCHIEBER, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 213 (01): : 1 - 3
  • [24] NUCLEAR RADIATION DETECTORS
    OUSEPH, PJ
    SCHWARTZ, M
    JOURNAL OF CHEMICAL EDUCATION, 1974, 51 (03) : A139 - &
  • [25] DETECTORS FOR NUCLEAR RADIATION
    TENKATE, WRT
    SENSORS AND ACTUATORS, 1986, 10 (1-2): : 83 - 101
  • [26] NUCLEAR RADIATION DETECTORS
    RADEKA, V
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1965, 36 (02): : 245 - &
  • [27] Keys to the enhanced performance of mercuric iodide radiation detectors provided by diffraction imaging
    Steiner, B
    van den Berg, L
    Laor, U
    APPLICATIONS OF SYNCHROTRON RADIATION TECHNIQUES TO MATERIALS SCIENCE V, 2000, 590 : 285 - 290
  • [28] RADIATION DETECTORS IN NUCLEAR RADIATION MEASUREMENTS
    DANIELS, WR
    JOURNAL OF THE INSTITUTION OF NUCLEAR ENGINEERS, 1972, 13 (05): : 137 - &
  • [29] RADIATION DOSE DEGRADATION OF SODIUM IODIDE DETECTORS
    MILLER, JC
    HEALTH PHYSICS, 1968, 15 (02): : 168 - +
  • [30] Synthesis and structural analysis of indium iodide polycrystal for room-temperature nuclear radiation detectors
    School of Information Science and Engineering, The Key Laboratory for Special Fiber and Fiber Sensor of Hebei Province, Yanshan University, Qinhuangdao, China
    Rengong Jingti Xuebao, 6 (1460-1464):