Simultaneous point-of-care testing of blood lipid profile and glucose: Performance evaluation of the GCare Lipid Analyzer

被引:1
|
作者
Kim, Ha Nui [1 ]
Yoon, Soo-Young [1 ]
机构
[1] Korea Univ, Dept Lab Med, Guro Hosp, 148 Gurodong Ro, Seoul 08308, South Korea
关键词
diabetes mellitus; dyslipidemia; glucose; lipid; POC; point-of-care testing; EDUCATION-PROGRAM RECOMMENDATIONS; DENSITY-LIPOPROTEIN CHOLESTEROL;
D O I
10.1002/jcla.24055
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Point-of-care (POC) testing provides quick results and includes tests for blood glucose and lipid profiles. We evaluated the newly developed POC device, the GCare Lipid Analyzer, which is used to measure glucose, total cholesterol (TC), triglyceride (TG), and high-density lipoprotein cholesterol (HDL-C) levels. Methods Venous and capillary blood samples were collected from patients who visited Korea University Guro Hospital. The results obtained using the GCare Lipid Analyzer were compared with those obtained using the TBA 2000FR chemistry analyzer and YSI 2300 STAT Plus analyzer. The glucose system evaluation process was based on the International Organization for Standardization 15197:2013 guidelines. Results The correlation coefficients (R) for TC, TG, and HDL-C were 0.965, 0.969, and 0.943 in capillary blood and 0.969, 0.990, and 0.956 in venous blood, respectively. The total errors for TC, TG, and HDL-C of the lipid profile using venous blood were all acceptable at 6.6%, 9.3%, and 11.6%, respectively. For glucose concentrations <100 mg/dl, 96.1% of the measured glucose levels were within +/- 15 mg/dl in venous samples and 100% were within +/- 15 mg/dl in capillary samples. For glucose concentrations >= 100 mg/dl, 100% and 99.5% of the measured glucose levels were within 15% for venous and capillary blood, respectively. Conclusion The performance of the GCare Lipid Analyzer is acceptable for both blood glucose and lipid profile testing, indicating that it is reliable for use in patients with diabetic dyslipidemia.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] The variability of results between point-of-care testing glucose meters and the central laboratory analyzer
    Khan, Adil I.
    Vasquez, Yolanda
    Gray, Jacquelyn
    Wians, Frank H., Jr.
    Kroll, Martin H.
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2006, 130 (10) : 1527 - 1532
  • [32] Point-of-care testing for the analysis of lipid panels: primary care diagnostic technology update
    Plueddemann, A.
    Thompson, M.
    Price, C. P.
    Wolstenholme, J.
    Heneghan, C.
    BRITISH JOURNAL OF GENERAL PRACTICE, 2012, 62 (596): : 165 - 166
  • [33] Evaluation of a point-of-care blood glucose monitor in healthy goats
    Quandt, Jane E.
    Barletta, Michele
    Cornell, Karen K.
    Giguere, Steeve
    Hofmeister, Erik H.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2018, 28 (01) : 45 - 53
  • [34] Evaluation of a new hemoglobin A1c analyzer for point-of-care testing
    Zhou, Rui
    Wang, Wei
    Song, Zhi-Xin
    Tong, Qing
    Wang, Qing-Tao
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2018, 32 (01)
  • [35] Evaluation of a point-of-care blood analyzer and determination of reference ranges for blood parameters in rockfish
    Harrenstien, LA
    Tornquist, SJ
    Miller-Morgan, TJ
    Fodness, BG
    Clifford, KE
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2005, 226 (02): : 255 - 265
  • [36] Point-of-care blood gas analysers: a performance evaluation
    St-Louis, P
    CLINICA CHIMICA ACTA, 2001, 307 (1-2) : 139 - 144
  • [37] The Impact of Inpatient Point-Of-Care Blood Glucose Quality Control Testing
    Corl, Dawn E.
    Yin, Tom S.
    Hoofnagle, Andrew N.
    Whitney, JoAnne D.
    Hirsch, Irl B.
    Wisse, Brent E.
    JOURNAL FOR HEALTHCARE QUALITY, 2012, 34 (04) : 24 - 32
  • [38] Blood glucose testing at the point-of-care - Clinical experience with the HemoCue B
    Koschinsky, T
    Heidkamp, P
    Reinauer, H
    DIABETES, 1998, 47 : A401 - A401
  • [39] Evaluation of the Analytical Performance of the Modified Enterprise Point-of-Care Blood Gas and Electrolyte Analyzer in a Pediatric Hospital
    Agarwal, Shweta
    Shafi, Rabia
    Edwards, Rachel M.
    Collymore, Laura
    Devaraj, Sridevi
    POINT OF CARE, 2014, 13 (04): : 132 - 136
  • [40] Examination of the precision of the Cholestech LDX® point-of-care testing device for lipid profiling
    Og, O'Donovan D.
    Byrne, S.
    McGillicuddy, A.
    Sahm, L.
    PHARMACOEPIDEMIOLOGY AND DRUG SAFETY, 2011, 20 (06) : 669 - 669