Determination of regional ventilation and perfusion in the lung using xenon and computed tomography

被引:62
|
作者
Kreck, TC
Krueger, MA
Altemeier, WA
Sinclair, SE
Robertson, HT
Shade, ED
Hildebrandt, J
Lamm, WJE
Frazer, DA
Polissar, NL
Hlastala, MP
机构
[1] Univ Washington, Div Pulm & Crit Care Med, Dept Med, Seattle, WA 98195 USA
[2] Univ Washington, Dept Physiol & Biophys, Seattle, WA 98195 USA
[3] Mt Whisper Light Stat Consulting, Seattle, WA 98112 USA
关键词
functional imaging; in vivo imaging; gas exchange; blood solubility; recirculation;
D O I
10.1152/jappl.2001.91.4.1741
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We propose a model to measure both regional ventilation ((V) over dot) and perfusion ((Q) over dot) in which the regional radiodensity (RD) in the lung during xenon (Xe) washin is a function of regional (V) over dot (increasing RD) and (Q) over dot (decreasing RD). We studied five anesthetized, paralyzed, mechanically ventilated, supine sheep. Four 2.5-mm-thick computed tomography (CT) images were simultaneously acquired immediately cephalad to the diaphragm at end inspiration for each breath during 3 min of Xe breathing. Observed changes in RD during Xe washin were used to determine regional (V) over dot and (Q) over dot. For 16 mm(3), displayed more variance than (V) over dot: the coefficient of variance of (Q) over dot (CV(Q) over dot) = 1.58 +/- 0.23, the CV of (V) over dot (CV(V) over dot) = 0.46 +/- 0.07, and the ratio of CV(Q) over dot to CV(V) over dot = 3.5 +/- 1.1. CV(Q) over dot (1.21 +/- 0.37) and the ratio of CV(Q) over dot to CV(V) over dot (2.4 +/- 1.2) were smaller at 1,000-mm(3) scale, but CV(V) over dot (0.53 +/- 0.09) was not, (V) over dot/(Q) over dot distributions also displayed scale dependence: log SD of (V) over dot and log SD of (Q) over dot were 0.79 +/- 0.05 and 0.85 +/- 0.10 for 16-mm(3) and 0.69 +/- 0.20 and 0.67 +/- 0.10 for 1,000-mm(3) regions of lung, respectively. (V) over dot and (Q) over dot measurements made with CT and Xe also demonstrate vertically oriented and isogravitational heterogeneity, which are described using other methodologies. Sequential images acquired by CT during Xe breathing can be used to determine both regional (V) over dot and (Q) over dot noninvasively with high spatial resolution.
引用
收藏
页码:1741 / 1749
页数:9
相关论文
共 50 条
  • [41] QUANTITATION OF ABSOLUTE REGIONAL MYOCARDIAL PERFUSION USING CINE COMPUTED-TOMOGRAPHY
    WEISS, RM
    OTOADESE, EA
    NOEL, MP
    DEJONG, SC
    HEERY, SD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (05) : 1186 - 1193
  • [42] QUANTITATION OF REGIONAL MYOCARDIAL PERFUSION IN HUMANS USING CINE COMPUTED-TOMOGRAPHY
    WEISS, RM
    GROVERMCKAY, M
    ROSSEN, JD
    STENBERG, RG
    STANFORD, W
    WINNIFORD, MD
    CLINICAL RESEARCH, 1990, 38 (03): : A808 - A808
  • [43] QUANTITATION OF REGIONAL MYOCARDIAL PERFUSION IN HUMANS USING CINE COMPUTED-TOMOGRAPHY
    WEISS, RM
    GROVERMCKAY, M
    ROSSEN, JD
    STENBERG, RG
    STANFORD, W
    WINNIFORD, MD
    CIRCULATION, 1990, 82 (04) : 125 - 125
  • [44] Regional Ventilation-Perfusion Matching by Electrical Impedance Tomography After Single Lung Transplant
    Scaravilli, Vittorio
    Colombo, Sebastiano Maria
    Fumagalli, Jacopo
    Mauri, Tommaso
    Zanella, Alberto
    Rosso, Lorenzo
    Grasselli, Giacomo
    ASAIO JOURNAL, 2024, 70 (03) : e49 - e52
  • [45] REGIONAL VENTILATION OF LUNG STUDIED WITH BOLUSES OF 133XENON
    DOLLFUSS, RE
    MILICEMI.J
    BATES, DV
    RESPIRATION PHYSIOLOGY, 1967, 2 (02): : 234 - &
  • [46] Two regional ventilation–perfusion patterns of lung consolidation assessed by electrical impedance tomography and ultrasound
    Na Wang
    Huaiwu He
    Yun Long
    Dawei Liu
    Qianling Wang
    Jing Jiang
    Yuechuan Xue
    Siyi Yuan
    Yi Chi
    Zhanqi Zhao
    Critical Care, 26
  • [47] Regional Lung Perfusion Using Different Indicators in Electrical Impedance Tomography
    Gaulton, Timothy G.
    Martin, Kevin
    Xin, Yi
    Victor, Marcus
    Santiago, Roberta Ribeiro De Santis
    Amato, Marcelo Britto Passos
    Berra, Lorenzo
    Cereda, Maurizio
    JOURNAL OF APPLIED PHYSIOLOGY, 2023, 135 (03) : 500 - 507
  • [48] Argon and xenon ventilation during prolonged ex vivo lung perfusion
    Martens, An
    Montoli, Matteo
    Faggi, Giulio
    Katz, Ira
    Pype, Jan
    Vanaudenaerde, Bart M.
    Van Raemdonck, Dirk E. M.
    Neyrinck, Arne P.
    JOURNAL OF SURGICAL RESEARCH, 2016, 201 (01) : 44 - 52
  • [49] RADIONUCLIDE COMPUTED-TOMOGRAPHY OF VENTILATION-PERFUSION RATIO
    MAEDA, H
    ITOH, H
    ISHII, Y
    TODO, G
    MUKAI, T
    TORIZUKA, K
    JOURNAL OF NUCLEAR MEDICINE, 1982, 23 (05) : P49 - P49
  • [50] SCINTIGRAPHIC DETERMINATION OF REGIONAL LUNG PERFUSION
    GIUNTINI, C
    FAZIO, F
    SANTOLICANDRO, AM
    NAVALESI, R
    JOURNAL OF NUCLEAR BIOLOGY AND MEDICINE, 1968, 12 (04): : 146 - +