Determination of regional ventilation and perfusion in the lung using xenon and computed tomography

被引:62
|
作者
Kreck, TC
Krueger, MA
Altemeier, WA
Sinclair, SE
Robertson, HT
Shade, ED
Hildebrandt, J
Lamm, WJE
Frazer, DA
Polissar, NL
Hlastala, MP
机构
[1] Univ Washington, Div Pulm & Crit Care Med, Dept Med, Seattle, WA 98195 USA
[2] Univ Washington, Dept Physiol & Biophys, Seattle, WA 98195 USA
[3] Mt Whisper Light Stat Consulting, Seattle, WA 98112 USA
关键词
functional imaging; in vivo imaging; gas exchange; blood solubility; recirculation;
D O I
10.1152/jappl.2001.91.4.1741
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We propose a model to measure both regional ventilation ((V) over dot) and perfusion ((Q) over dot) in which the regional radiodensity (RD) in the lung during xenon (Xe) washin is a function of regional (V) over dot (increasing RD) and (Q) over dot (decreasing RD). We studied five anesthetized, paralyzed, mechanically ventilated, supine sheep. Four 2.5-mm-thick computed tomography (CT) images were simultaneously acquired immediately cephalad to the diaphragm at end inspiration for each breath during 3 min of Xe breathing. Observed changes in RD during Xe washin were used to determine regional (V) over dot and (Q) over dot. For 16 mm(3), displayed more variance than (V) over dot: the coefficient of variance of (Q) over dot (CV(Q) over dot) = 1.58 +/- 0.23, the CV of (V) over dot (CV(V) over dot) = 0.46 +/- 0.07, and the ratio of CV(Q) over dot to CV(V) over dot = 3.5 +/- 1.1. CV(Q) over dot (1.21 +/- 0.37) and the ratio of CV(Q) over dot to CV(V) over dot (2.4 +/- 1.2) were smaller at 1,000-mm(3) scale, but CV(V) over dot (0.53 +/- 0.09) was not, (V) over dot/(Q) over dot distributions also displayed scale dependence: log SD of (V) over dot and log SD of (Q) over dot were 0.79 +/- 0.05 and 0.85 +/- 0.10 for 16-mm(3) and 0.69 +/- 0.20 and 0.67 +/- 0.10 for 1,000-mm(3) regions of lung, respectively. (V) over dot and (Q) over dot measurements made with CT and Xe also demonstrate vertically oriented and isogravitational heterogeneity, which are described using other methodologies. Sequential images acquired by CT during Xe breathing can be used to determine both regional (V) over dot and (Q) over dot noninvasively with high spatial resolution.
引用
收藏
页码:1741 / 1749
页数:9
相关论文
共 50 条
  • [31] EFFECT OF AGE ON REGIONAL LUNG VENTILATION AND PERFUSION
    KRONENBERG, RS
    PONTO, RA
    EBERT, RV
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1971, 78 (06): : 1008 - +
  • [32] Quantifying Regional Lung Deformation Using Four-Dimensional Computed Tomography: A Comparison of Conventional and Oscillatory Ventilation
    Herrmann, Jacob
    Gerard, Sarah E.
    Shao, Wei
    Hawley, Monica L.
    Reinhardt, Joseph M.
    Christensen, Gary E.
    Hoffman, Eric A.
    Kaczka, David W.
    FRONTIERS IN PHYSIOLOGY, 2020, 11
  • [33] Effect of histamine on regional lung ventilation studied by synchrotron radiation computed tomography (SRCT)
    Monfraix, S
    Porra, L
    Bayat, S
    Leduc, G
    Thomlinson, W
    Suortti, P
    Standertsköld-Nordenstam, CG
    Sovijärvi, ARA
    FASEB JOURNAL, 2002, 16 (05): : A1148 - A1148
  • [34] REGIONAL STUDY OF VENTILATION BY XENON 133 AND PULMONARY PERFUSION USING MICROSPHERES LABELLED WITH TECHNETIUM 99
    BERNARD, JPD
    MORET, R
    TEYSSONN.D
    TOURAINE, R
    REVUE FRANCAISE DES MALADIES RESPIRATOIRES, 1974, 2 (03): : 278 - 286
  • [35] Ventilation-perfusion lung scanning and spiral computed tomography of the lungs: Competing or complementary modalities?
    Robinson, PJA
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (11): : 1547 - 1553
  • [36] Correlation of regional cerebral blood flow values obtained by perfusion-MRI and stable xenon computed tomography
    Hagen, T
    Bartylla, K
    Piepgras, U
    RIVISTA DI NEURORADIOLOGIA, 1998, 11 : 176 - 178
  • [37] Computed tomography scan versus ventilation-perfusion lung scan in the detection of pulmonary embolism
    Cueto, SM
    Cavanaugh, SH
    Benenson, RS
    Redclift, MS
    JOURNAL OF EMERGENCY MEDICINE, 2001, 21 (02): : 155 - 164
  • [38] LOCAL PULMONARY VENTILATION USING NONRADIOACTIVE XENON-ENHANCED ULTRAFAST COMPUTED-TOMOGRAPHY
    MURPHY, DMF
    NICEWICZ, JT
    ZABBATINO, SM
    MOORE, RA
    CHEST, 1989, 96 (04) : 799 - 804
  • [39] Xenon Ventilation Imaging Using Dual-Energy Computed Tomography in Asthmatics Initial Experience
    Chae, Eun Jin
    Seo, Joon Beom
    Lee, Jeongjin
    Kim, Namkug
    Goo, Hyun Woo
    Lee, Hyun Joo
    Lee, Choong Wook
    Ra, Seung Won
    Oh, Yeon-Mok
    Cho, You Sook
    INVESTIGATIVE RADIOLOGY, 2010, 45 (06) : 354 - 361
  • [40] XENON VENTILATION AND PERFUSION STUDIES
    JOHNSON, PC
    JOURNAL OF NUCLEAR MEDICINE, 1969, 10 (06) : 412 - &