Exergoeconomic optimization of a new double-flash geothermal-based combined cooling and power (CCP) system at two different cooling temperatures assisted by boosters

被引:84
|
作者
Tian, Man-Wen [1 ]
Parikhani, Towhid [2 ]
Jermsittiparsert, Kittisak [3 ,5 ]
Ashraf, Muhammad Aqeel [4 ]
机构
[1] Yango Univ, Inst Smart Finance, Fuzhou 350015, Peoples R China
[2] Islamic Azad Univ, Ardabil Branch, Young Researchers & Elite Club, Ardebil, Iran
[3] Ton Duc Thang Univ, Dept Management Sci & Technol Dev, Ho Chi Minh City, Vietnam
[4] China Univ Geosci, Sch Environm Studies, Wuhan 430074, Peoples R China
[5] Ton Duc Thang Univ, Fac Social Sci & Humanities, Ho Chi Minh City, Vietnam
关键词
Flash-binary geothermal; Cogeneration; Bi-evaporator; Exergoeconomic optimization; THERMOECONOMIC ANALYSIS; MULTIGENERATION SYSTEM; PERFORMANCE ASSESSMENT; REFRIGERATION CYCLE; HEAT-SOURCE; ENERGY; EXERGY; DRIVEN;
D O I
10.1016/j.jclepro.2020.120921
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new cooling/power cogeneration system applicable to double-flash geothermal power plants is devised which provides cooling load at two different adjustable cooling temperatures. To further increase efficiency of the set-up, two boosters are employed to boost pressure of the secondary flow of each ejector due to the considerable drop of pressure of the geofluid through the steam turbines as well as the throttling valves. A comprehensive modeling of the proposed system is achieved from thermodynamics laws as well as economic perspectives and the results are elaborated with more details. In comparison with the previous integrated systems based on the flash geothermal power plants, the present system produces around 47.8% more cooling load and 38.9% more electricity. Also, the results of multi-objective optimization revealed that the net electrical power and exergetic efficiency can be increased approximately 20.59% and 68.11%, respectively. However, the unit cost of power and cooling (UCPC) is decreased around 36.3%. Meantime, the total exergy destruction rate is decreased after optimization. Among all elements, the highest exergy destruction occurred in the condenser by 2570 kW out of 7609 kW (in base mode) and 2333 kW out of 6836 kW (in optimum mode). Also, it is found that the energy efficiency of the proposed system can be increased by increasing turbines outlet pressure, boosters pressure ratio, and separator 1 pressure or decreasing separator 2 pressure. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:17
相关论文
共 39 条
  • [31] Exergoeconomic, water footprint-based exergoenvironmental impact and optimization of a new flash-binary geothermal power generation system using an improved grey relational method
    Sohbatloo, Arezoo
    Rostami, Nassim
    Boyaghchi, Fateme Ahmadi
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2022, 147 (15) : 8411 - 8434
  • [32] Economic examination and multi-objective optimization of integrating a novel geothermal-driven combined cooling and power (CCP) system using a bi-evaporator cycle with a low-temperature electrolyzer
    Cao, Yan
    Dhahad, Hayder A.
    El-Shafay, A. S.
    Ahmed, Ahmed Najat
    Mohamed, Abdullah
    Almojil, Sattam Fahad
    Almohana, Abdulaziz Ibrahim
    Alali, Abdulrhman Fahmi
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (46) : 19955 - 19976
  • [33] Exergoeconomic analysis and optimization of a combined cooling, heating and power system based on organic Rankine and Kalina cycles using liquified natural gas cold energy (vol 238, 114148, 2021)
    Fang, Zhenhua
    Shang, Liyan
    Pan, Zhen
    Yao, Xiuqing
    Ma, Guiyang
    Zhang, Zhien
    ENERGY CONVERSION AND MANAGEMENT, 2021, 240
  • [34] Optimization and performance assessment of solar-assisted combined cooling, heating and power system systems: Multi-objective gradient-based optimizer
    Li, Ling-Ling
    Qu, Li-Nan
    Tseng, Ming-Lang
    Lim, Ming K.
    Ren, Xin-Yu
    Miao, Yan
    ENERGY, 2024, 289
  • [35] Optimization on building combined cooling, heating, and power system considering load uncertainty based on scenario generation method and two-stage stochastic programming
    Ruan, Yingjun
    Qian, Fanyue
    Sun, Ke
    Meng, Hua
    SUSTAINABLE CITIES AND SOCIETY, 2023, 89
  • [36] A nuclear-driven combined cooling and power system based on supercritical and transcritical CO2 cycles: energy, exergy, and exergoeconomic analysis, multi-objective optimization and reactor startup analysis
    Wang, Mengxuan
    Wang, Jiangfeng
    Luo, Fang
    Lou, Juwei
    Zhang, Junyi
    NUCLEAR ENGINEERING AND DESIGN, 2025, 432
  • [37] Performance optimization for a novel combined cooling, heating and power-organic Rankine cycle system with improved following electric load strategy based on different objectives
    Han, Zhonghe
    Zhang, Han
    Wu, Di
    Ma, Fanfan
    ENERGY CONVERSION AND MANAGEMENT, 2020, 221
  • [38] Optimization and performance comparison of combined cooling, heating and power/ground source heat pump/photovoltaic/solar thermal system under different load ratio for two operation strategies
    Zeng, Rong
    Zhang, Xiaofeng
    Deng, Yan
    Li, Hongqiang
    Zhang, Guoqiang
    ENERGY CONVERSION AND MANAGEMENT, 2020, 208
  • [39] Multi-criteria optimization of a biomass gasification-based combined cooling, heating, and power system integrated with an organic Rankine cycle in different climate zones in China
    Li, C. Y.
    Wu, J. Y.
    Dai, Y. J.
    Wang, Chi-Hwa
    ENERGY CONVERSION AND MANAGEMENT, 2021, 243