Exergoeconomic optimization of a new double-flash geothermal-based combined cooling and power (CCP) system at two different cooling temperatures assisted by boosters

被引:84
|
作者
Tian, Man-Wen [1 ]
Parikhani, Towhid [2 ]
Jermsittiparsert, Kittisak [3 ,5 ]
Ashraf, Muhammad Aqeel [4 ]
机构
[1] Yango Univ, Inst Smart Finance, Fuzhou 350015, Peoples R China
[2] Islamic Azad Univ, Ardabil Branch, Young Researchers & Elite Club, Ardebil, Iran
[3] Ton Duc Thang Univ, Dept Management Sci & Technol Dev, Ho Chi Minh City, Vietnam
[4] China Univ Geosci, Sch Environm Studies, Wuhan 430074, Peoples R China
[5] Ton Duc Thang Univ, Fac Social Sci & Humanities, Ho Chi Minh City, Vietnam
关键词
Flash-binary geothermal; Cogeneration; Bi-evaporator; Exergoeconomic optimization; THERMOECONOMIC ANALYSIS; MULTIGENERATION SYSTEM; PERFORMANCE ASSESSMENT; REFRIGERATION CYCLE; HEAT-SOURCE; ENERGY; EXERGY; DRIVEN;
D O I
10.1016/j.jclepro.2020.120921
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new cooling/power cogeneration system applicable to double-flash geothermal power plants is devised which provides cooling load at two different adjustable cooling temperatures. To further increase efficiency of the set-up, two boosters are employed to boost pressure of the secondary flow of each ejector due to the considerable drop of pressure of the geofluid through the steam turbines as well as the throttling valves. A comprehensive modeling of the proposed system is achieved from thermodynamics laws as well as economic perspectives and the results are elaborated with more details. In comparison with the previous integrated systems based on the flash geothermal power plants, the present system produces around 47.8% more cooling load and 38.9% more electricity. Also, the results of multi-objective optimization revealed that the net electrical power and exergetic efficiency can be increased approximately 20.59% and 68.11%, respectively. However, the unit cost of power and cooling (UCPC) is decreased around 36.3%. Meantime, the total exergy destruction rate is decreased after optimization. Among all elements, the highest exergy destruction occurred in the condenser by 2570 kW out of 7609 kW (in base mode) and 2333 kW out of 6836 kW (in optimum mode). Also, it is found that the energy efficiency of the proposed system can be increased by increasing turbines outlet pressure, boosters pressure ratio, and separator 1 pressure or decreasing separator 2 pressure. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:17
相关论文
共 39 条
  • [21] A geothermal-based freshwater/cooling system assisted by heat recovery sections: 3E analysis and techno-economic optimization using genetic algorithm
    Abouzied, Amr S.
    Basem, Ali
    Shaban, Mohamed
    Alhomayani, Fahad M.
    Dutta, Ashit Kumar
    Abduvalieva, Dilsora
    Elmasry, Yasser
    Khan, Baseem
    Almadhor, Ahmad
    Alrawashdeh, Albara Ibrahim
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 63
  • [22] Thermodynamic and exergoeconomic analyses and performance assessment of a new configuration of a combined cooling and power generation system based on ORC-VCR
    Mahmoudan, Alireza
    Samadof, Parviz
    Sadeghzadeh, Milad
    Jalili, Mohamad
    Sharifpur, Mohsen
    Kumar, Ravinder
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 145 (03) : 1163 - 1189
  • [23] Modeling of calculations on the performance optimization of a double-flash geothermal renewable energy-based combined heat/power plant coupled by transcritical carbon dioxide rankine cycle
    Leng, Yuchi
    Li, Shuguang
    Elmasry, Yasser
    AL Garalleh, Hakim
    Afandi, Abdulkareem
    Alzubaidi, Laith H.
    Alkhalaf, Salem
    Abdullaev, Sherzod
    Alharbi, Fawaz S.
    RENEWABLE ENERGY, 2024, 237
  • [24] Multi-objective optimization and exergoeconomic analysis for a novel full-spectrum solar-assisted methanol combined cooling, heating, and power system
    Han, Zepeng
    Wang, Jiangjiang
    Cui, Zhiheng
    Lu, Chunyan
    Qi, Xiaoling
    ENERGY, 2021, 237
  • [25] Performance assessment and optimization of a novel geothermal combined cooling and power system integrating an organic flash cycle with an ammonia-water absorption refrigeration cycle
    Wu, Chuang
    Xu, Xiaoxiao
    Li, Qibin
    Li, Xiaoxiao
    Liu, Lang
    Liu, Chao
    ENERGY CONVERSION AND MANAGEMENT, 2021, 227
  • [26] Multi-objective optimization and multi-aspect analysis of an innovative geothermal-based multi-generation energy system for power, cooling, hydrogen, and freshwater production
    Li, Kun
    Ding, Yi-Zhe
    Ai, Chen
    Sun, Hongwei
    Xu, Yi-Peng
    Nedaei, Navid
    ENERGY, 2022, 245
  • [27] Exergoeconomic analysis and optimization of a combined cooling, heating and power system based on organic Rankine and Kalina cycles using liquified natural gas cold energy
    Fang, Zhenhua
    Shang, Liyan
    Pan, Zhen
    Yao, Xiuqing
    Ma, Guiyang
    Zhang, Zhien
    ENERGY CONVERSION AND MANAGEMENT, 2021, 238
  • [28] Investigation of new combined cooling, heating and power system based on solar thermal power and single-double-effect refrigeration cycle
    Alharthi, Mathkar A.
    Khaliq, Abdul
    Alqaed, Saeed
    Almehmadi, Fahad
    ENERGY REPORTS, 2023, 9 : 289 - 309
  • [29] Investigation of new combined cooling, heating and power system based on solar thermal power and single-double-effect refrigeration cycle
    Alharthi, Mathkar A.
    Khaliq, Abdul
    Alqaed, Saeed
    Almehmadi, Fahad
    ENERGY REPORTS, 2023, 9 : 289 - 309
  • [30] Exergoeconomic, water footprint-based exergoenvironmental impact and optimization of a new flash-binary geothermal power generation system using an improved grey relational method
    Arezoo Sohbatloo
    Nassim Rostami
    Fateme Ahmadi Boyaghchi
    Journal of Thermal Analysis and Calorimetry, 2022, 147 : 8411 - 8434