Standardization of 8-color flow cytometry across different flow cytometer instruments: A feasibility study in clinical laboratories in Switzerland

被引:28
|
作者
Glier, Hana [1 ]
Heijnen, Ingmar [2 ]
Hauwel, Mathieu [3 ]
Dirks, Jan [4 ]
Quarroz, Stephane [5 ]
Lehmann, Thomas [6 ]
Rovo, Alicia [4 ]
Arn, Kornelius [7 ]
Matthes, Thomas [3 ]
Hogan, Cassandra [3 ]
Keller, Peter [8 ]
Dudkiewicz, Ewa [9 ]
Stussi, Georg [10 ,11 ]
Fernandez, Paula [1 ]
机构
[1] Cantonal Hosp Aarau, Inst Lab Med, Aarau, Switzerland
[2] Univ Hosp Basel, Med Immunol, Basel, Switzerland
[3] Geneva Univ Hosp, Hematol Lab, Geneva, Switzerland
[4] Univ Hosp Basel, Diagnost Hematol, Basel, Switzerland
[5] Vaudoise Univ Hosp Ctr, Hematol Lab, Lausanne, Switzerland
[6] Ctr Lab Med, Clin Chem Hematol & Immunol Lab, St Gallen, Switzerland
[7] Cantonal Hosp, Ctr Lab Med, Luzern, Switzerland
[8] Univ Bern, Univ Clin Hematol, Univ Hosp Bern, Inselspital, Bern, Switzerland
[9] Univ Hosp Zurich, Hematol Clin, Zurich, Switzerland
[10] Reg Hosp Bellinzona & Valli, Oncol Inst Southern Switzerland, Hematol Lab, Bellinzona, Switzerland
[11] Reg Hosp Bellinzona & Valli, EOLAB, Bellinzona, Switzerland
关键词
Flow cytometry; Cross-platform standardization; Canto; Navios; EuroFlow;
D O I
10.1016/j.jim.2017.07.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The EuroFlow Consortium developed a fully standardized flow cytometric approach from instrument settings, through antibody panel, reagents and sample preparation protocols, to data acquisition and analysis. The Swiss Cytometry Society (SCS) promoted a study to evaluate the feasibility of using such standardized measurements of 8-color data across two different flow cytometry platforms - Becton Dickinson (BD) FACSCanto II and Beckman Coulter (BC) Navios, aiming at increasing reproducibility and inter-laboratory comparability of immunophenotypic data in clinical laboratories in Switzerland. The study was performed in two phases, i.e. a learning phase (round 1) and an analytical phase (rounds 2 and 3) consisting of a total of three rounds. Overall, 10 laboratories using BD FACSCanto II (n = 6) or BC Navios (n = 4) flow cytometers participated. Each laboratory measured peripheral blood samples from healthy donors stained with a uniform antibody panel of reagents - EuroFlow Lymphoid Screening Tube (LST) - applying the EuroFlow standardized protocols for instrument setup and sample preparation (www.EuroFlow.org). All data files were analyzed centrally and median fluorescence intensity (MedFI) values for individual markers on defined lymphocyte subsets were recorded; variability from reference MedFI values was assessed using performance scores. Data troubleshooting and discussion of the results with the participants followed after each round at SCS meetings. The results of the learning phase demonstrated that standardized instrument setup and data acquisition are feasible in routine clinical laboratories without previous experience with EuroFlow. During the analytical phase, highly comparable data were obtained at the different laboratories using either BD FACSCanto II or BC Navios. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%. In the last study round, 89% of participants scored over 90% MedFI values within the acceptance criteria (P-score), in line with the results of the EuroFlow quality assessment rounds performed by the EuroFlow expert laboratories(Kalina et al., 2015). Central analysis of data allowed identification of deviations from the standardized procedures and technical issues (e.g. failure to perform correct instrument setup and improper compensation). In summary, here we show that inter-laboratory cross-platform standardization of 8-color flow cytometric measurements in clinical laboratories is feasible and allows for fully comparable MedFI results across BD FACSCanto II and BC Navios instruments. However, adherence to standardized protocols is crucial. Thus, training of the laboratory personnel in the EuroFlow standardized procedures is highly recommended to prevent errors in instrument setup and sample preparation.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] CD14 in 8-Color Flow Cytometry Distinguishes Monocytes From Rare Cells of Large B-Cell Lymphoma and Hairy Cell Leukemia
    Moench, Laura
    Singleton, Timothy P.
    Linden, Michael
    McKenna, Robert W.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2012, 138 (03) : 470 - 470
  • [32] Comparison of Minimal Residual Disease Detection in Autografts of Patients with Multiple Myeloma between 8-Color Multiparameter Flow Cytometry (EuroFlow) and Next-Generation Sequencing
    Takamatsu, Hiroyuki
    Takezako, Naoki
    Wee, Rachel K.
    Yoroidaka, Takeshi
    Yamashita, Takeshi
    Murata, Ryoichi
    Matsue, Kosei
    Nakao, Shinji
    BLOOD, 2018, 132
  • [33] Minimal Residual Disease (MRD) By 8-Color Flow Cytometry (Flow-MRD) and IGH Clonospecific Quantitative PCR (ASO RQPCR) Reached Similar Performances for Evaluation of CLL Treatment in a Phase II Clinical Trial: Cross Validation of the Methods
    Letestu, Remi
    Cartron, Guillaume
    Lepretre, Stephane
    Le Garff-Tavernier, Magali
    Solly, Francoise
    Campos, Lydia
    Ticchioni, Michel
    Quiney, Claire
    Dahmani, Abdelmalek
    Boubaya, Marouane
    Levy, Vincent
    Cymbalista, Florence
    Delfau-Larue, Marie-Helene
    BLOOD, 2014, 124 (21)
  • [34] CD34+ cell subpopulations detected by 8-color flow cytometry in bone marrow and in peripheral blood stem cell collections: application for MRD detection in leukemia patients
    Elisabet Björklund
    Astrid Gruber
    Joanna Mazur
    Anna Mårtensson
    Mona Hansson
    Anna Porwit
    International Journal of Hematology, 2009, 90 : 292 - 302
  • [35] CD34+ cell subpopulations detected by 8-color flow cytometry in bone marrow and in peripheral blood stem cell collections: application for MRD detection in leukemia patients
    Bjorklund, Elisabet
    Gruber, Astrid
    Mazur, Joanna
    Martensson, Anna
    Hansson, Mona
    Porwit, Anna
    INTERNATIONAL JOURNAL OF HEMATOLOGY, 2009, 90 (03) : 292 - 302
  • [36] Fibrocyte, CD13+Monocyte and CXCR4+/Col+ Macrophage Infiltrates in a Murine Pulmonary Model of Fibrosis Detected Using 8-color Flow Cytometry
    Achuthanandam, Ram
    Rafferty, Patricia
    Cochlin, Karyn
    Mathur, Ashok
    Capocasale, Renold J.
    Ort, Tatiana
    Ekert, Jason
    Branigan, Patrick
    Das, Anuk
    Bugelski, Peter
    FASEB JOURNAL, 2008, 22
  • [37] Minimal Residual Disease Monitoring By 8-Color Flow Cytometry in Mantle Cell Lymphoma Is Complementary to Q-PCR Monitoring and Will Facilitate Pre-Emptive Treatment: An EU-MCL and Lysa Study
    Cheminant, Morgane
    Schmit, Stephanie
    Touzart, Aurore
    Derrieux, Coralie
    Delfau-Larue, Marie Helene
    Thieblemont, Catherine
    Ribrag, Vincent
    Ysebaert, Loic
    Jardin, Fabrice
    Cheze, Stephane
    Lefrere, Francois
    Delarue, Richard
    Pott, Christiane
    Hotter, Eva
    Dreyling, Martin
    Asnafi, Vahid
    Hermine, Olivier
    Macintyre, Elizabeth
    BLOOD, 2014, 124 (21)
  • [38] Minimal Residual Disease in Autografts and Bone Marrow of Patients with Multiple Myeloma: 8-Color Multiparameter Flow Cytometry (EuroFlow- NGF) Vs. Next-Generation Sequencing
    Takamatsu, Hiroyuki
    Takezako, Naoki
    Yoroidaka, Takeshi
    Yamashita, Takeshi
    Murata, Ryoichi
    Yamazaki, Atsuko
    Takeuchi, Masahiro
    Mimura, Naoya
    Nakaseko, Chiaki
    Sakaida, Emiko
    Onoda, Masahiro
    Utsu, Yoshikazu
    Fukazawa, Motoharu
    Matsue, Kosei
    Nakao, Shinji
    BLOOD, 2020, 136
  • [39] A PHENOTYPIC STUDY OF CD8(+) LYMPHOCYTE SUBSETS IN INFANTS USING 3-COLOR FLOW-CYTOMETRY
    JENNINGS, C
    RICH, K
    SIEGEL, JN
    LANDAY, A
    CLINICAL IMMUNOLOGY AND IMMUNOPATHOLOGY, 1994, 71 (01): : 8 - 13
  • [40] COMPARISON BETWEEN 8-COLOR MULTIPARAMETER FLOW CYTOMETRY AND NEXT-GENERATION SEQUENCING TO DETECT MINIMAL RESIDUAL DISEASE IN MULTIPLE MYELOMA PATIENTS WHO UNDERWENT AUTO-SCT
    Takamatsu, H.
    Wee, R.
    Takezako, N.
    Zheng, J.
    Carlton, V.
    Moorhead, M.
    Yoshida, T.
    Faham, M.
    Nakao, S.
    HAEMATOLOGICA, 2016, 101 : 535 - 535