Standardization of 8-color flow cytometry across different flow cytometer instruments: A feasibility study in clinical laboratories in Switzerland

被引:28
|
作者
Glier, Hana [1 ]
Heijnen, Ingmar [2 ]
Hauwel, Mathieu [3 ]
Dirks, Jan [4 ]
Quarroz, Stephane [5 ]
Lehmann, Thomas [6 ]
Rovo, Alicia [4 ]
Arn, Kornelius [7 ]
Matthes, Thomas [3 ]
Hogan, Cassandra [3 ]
Keller, Peter [8 ]
Dudkiewicz, Ewa [9 ]
Stussi, Georg [10 ,11 ]
Fernandez, Paula [1 ]
机构
[1] Cantonal Hosp Aarau, Inst Lab Med, Aarau, Switzerland
[2] Univ Hosp Basel, Med Immunol, Basel, Switzerland
[3] Geneva Univ Hosp, Hematol Lab, Geneva, Switzerland
[4] Univ Hosp Basel, Diagnost Hematol, Basel, Switzerland
[5] Vaudoise Univ Hosp Ctr, Hematol Lab, Lausanne, Switzerland
[6] Ctr Lab Med, Clin Chem Hematol & Immunol Lab, St Gallen, Switzerland
[7] Cantonal Hosp, Ctr Lab Med, Luzern, Switzerland
[8] Univ Bern, Univ Clin Hematol, Univ Hosp Bern, Inselspital, Bern, Switzerland
[9] Univ Hosp Zurich, Hematol Clin, Zurich, Switzerland
[10] Reg Hosp Bellinzona & Valli, Oncol Inst Southern Switzerland, Hematol Lab, Bellinzona, Switzerland
[11] Reg Hosp Bellinzona & Valli, EOLAB, Bellinzona, Switzerland
关键词
Flow cytometry; Cross-platform standardization; Canto; Navios; EuroFlow;
D O I
10.1016/j.jim.2017.07.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The EuroFlow Consortium developed a fully standardized flow cytometric approach from instrument settings, through antibody panel, reagents and sample preparation protocols, to data acquisition and analysis. The Swiss Cytometry Society (SCS) promoted a study to evaluate the feasibility of using such standardized measurements of 8-color data across two different flow cytometry platforms - Becton Dickinson (BD) FACSCanto II and Beckman Coulter (BC) Navios, aiming at increasing reproducibility and inter-laboratory comparability of immunophenotypic data in clinical laboratories in Switzerland. The study was performed in two phases, i.e. a learning phase (round 1) and an analytical phase (rounds 2 and 3) consisting of a total of three rounds. Overall, 10 laboratories using BD FACSCanto II (n = 6) or BC Navios (n = 4) flow cytometers participated. Each laboratory measured peripheral blood samples from healthy donors stained with a uniform antibody panel of reagents - EuroFlow Lymphoid Screening Tube (LST) - applying the EuroFlow standardized protocols for instrument setup and sample preparation (www.EuroFlow.org). All data files were analyzed centrally and median fluorescence intensity (MedFI) values for individual markers on defined lymphocyte subsets were recorded; variability from reference MedFI values was assessed using performance scores. Data troubleshooting and discussion of the results with the participants followed after each round at SCS meetings. The results of the learning phase demonstrated that standardized instrument setup and data acquisition are feasible in routine clinical laboratories without previous experience with EuroFlow. During the analytical phase, highly comparable data were obtained at the different laboratories using either BD FACSCanto II or BC Navios. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%. In the last study round, 89% of participants scored over 90% MedFI values within the acceptance criteria (P-score), in line with the results of the EuroFlow quality assessment rounds performed by the EuroFlow expert laboratories(Kalina et al., 2015). Central analysis of data allowed identification of deviations from the standardized procedures and technical issues (e.g. failure to perform correct instrument setup and improper compensation). In summary, here we show that inter-laboratory cross-platform standardization of 8-color flow cytometric measurements in clinical laboratories is feasible and allows for fully comparable MedFI results across BD FACSCanto II and BC Navios instruments. However, adherence to standardized protocols is crucial. Thus, training of the laboratory personnel in the EuroFlow standardized procedures is highly recommended to prevent errors in instrument setup and sample preparation.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] COMPARISON OF 8-COLOR FLOW CYTOMETRY AND PCR-BASED METHODS IN MEASUREMENT OF MINIMAL RESIDUAL DISEASE IN ADULT ACUTE LYMPHOBLASTIC LEUKEMIA
    Hrabovsky, S.
    Folber, F.
    Horacek, J.
    Stehlikova, O.
    Jelinkova, H.
    Salek, C.
    Doubek, M.
    HAEMATOLOGICA, 2017, 102 : 347 - 347
  • [22] Prognostic Significance of Minimal Residual Disease in Adult Patients with B-Lineage Acute Lymphoblastic Leukemia by 8-Color Flow Cytometry
    Weng, Xiang-Qin
    Shen, Yang
    Sheng, Yan
    Chen, Bing
    Wang, Jing-han
    Li, Jun-ming
    Zhu, Yong-Mei
    Chen, Sai-Juan
    BLOOD, 2012, 120 (21)
  • [23] Detecting minimal residual disease in patients with chronic lymphocytic leukemia using 8-color flow cytometry protocol in routine hematological practice
    Stehlikova, O.
    Chovancova, J.
    Tichy, B.
    Krejci, M.
    Brychtova, Y.
    Panovska, A.
    Skuhrova, H. Francova
    Burckova, K.
    Borsky, M.
    Loja, T.
    Mayer, J.
    Pospisilova, S.
    Doubek, M.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2014, 36 (02) : 165 - 171
  • [24] THE RATIO OF PATHOLOGICAL PLASMOCYTES, ASSESSED BY 8-COLOR FLOW CYTOMETRY, PREDICTS OF RISK OF EVOLUTION IN MONOCLONAL GAMMOPATHY OF UNKNOWN SIGNIFICANCE AND SMOULDERING MULTIPLE MYELOMA
    Brouzes, C.
    Lhermitte, L.
    Zaratzian, C.
    Chandesris, M. O.
    Frenzel, L.
    Delarue, R.
    Suarez, F.
    Hermine, O.
    Macintyre, E.
    Asnafi, V.
    HAEMATOLOGICA, 2017, 102 : 506 - 506
  • [25] Sunitinib affects specific subpopulations of peripheral blood monocytic cells in patients with unresectable Neuroendocrine Tumor (NET): An 8-color flow cytometry analysis
    Zurita, Amado J.
    Wu, Hua-Kang
    Kulke, Matthew
    Tye, Lesley
    Bello, Carlo L.
    DePrimo, Samuel E.
    McKee, Kathryn S.
    Heymach, John V.
    MOLECULAR CANCER THERAPEUTICS, 2007, 6 (12) : 3580S - 3580S
  • [26] Plasma Cell Phenotyping and DNA Content Analysis by 8-Color Flow Cytometry: A Highly Sensitive Assay That Simultaneously Measures Clonality, Ploidy, and Proliferation
    Morice, W. G., II
    Timm, M. M.
    Jevremovic, D.
    Ketterling, R. P.
    Kumar, S.
    Reichard, K. K.
    MODERN PATHOLOGY, 2013, 26 : 349A - 350A
  • [27] Plasma Cell Phenotyping and DNA Content Analysis by 8-Color Flow Cytometry: A Highly Sensitive Assay That Simultaneously Measures Clonality, Ploidy, and Proliferation
    Morice, W. G., II
    Timm, M. M.
    Jevremovic, D.
    Ketterling, R. P.
    Kumar, S.
    Reichard, K. K.
    LABORATORY INVESTIGATION, 2013, 93 : 349A - 350A
  • [28] B-Cell and Plasma Cell Clones with Identical Light Chain Expression by 8-Color Flow Cytometry and DNA Content Analysis: A Predictor of Diagnosis?
    Rosado, F. N.
    Morice, W. G.
    He, R.
    Howard, M. T.
    McPhail, E. D.
    LABORATORY INVESTIGATION, 2013, 93 : 358A - 358A
  • [29] STANDARDIZATION OF ABSOLUTE CD4(+) LYMPHOCYTE COUNTS ACROSS LABORATORIES - AN EVALUATION OF THE ORTHO CYTORONABSOLUTE FLOW-CYTOMETRY SYSTEM ON NORMAL DONORS
    CONNELLY, MC
    KNIGHT, M
    GIORGI, JV
    KAGAN, J
    LANDAY, AL
    PARKER, JW
    PAGE, E
    SPINO, C
    WILKENING, C
    MERCOLINO, TJ
    CYTOMETRY, 1995, 22 (03): : 200 - 210
  • [30] B-Cell and Plasma Cell Clones with Identical Light Chain Expression by 8-Color Flow Cytometry and DNA Content Analysis: A Predictor of Diagnosis?
    Rosado, F. N.
    Morice, W. G.
    He, R.
    Howard, M. T.